ANNUAL PUMP TEST 23
20 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

According to the policy, when will pumpers be tested annually?

  • On the first Monday in March (correct)
  • On the first Monday in June
  • On the first Monday in May
  • On the first Monday in April

Who is responsible for testing the pumpers on an annual basis?

  • The Fire Commissioner
  • The Training Division (correct)
  • The Company Officer
  • The Apparatus Officer

What is the purpose of the pre-test check before a pump test is performed?

  • To engage the priming pump
  • To check the priming capability of the pumper (correct)
  • To observe the compound gauge
  • To check the oil level in the priming tank

According to the text, what is the minimum depth to which the suction strainer should be submerged?

<p>2 feet (A)</p> Signup and view all the answers

What should be the reading on the master pump pressure gauge when the pump is primed?

<p>50 psi (D)</p> Signup and view all the answers

What is the net pump pressure required to provide a 700 gpm discharge with a 2-1/2" high-pressure hoseline and a 1-3/4" tip?

<p>200 psi (B)</p> Signup and view all the answers

Which valve must be tested before disconnecting hoselines from the apparatus?

<p>Relief valve (A)</p> Signup and view all the answers

What is the purpose of opening the drains on relief valves with drains?

<p>To clean the relief valve strainers (C)</p> Signup and view all the answers

What is the minimum flow rate required for the tank-to-pump valve test?

<p>500 gpm (B)</p> Signup and view all the answers

Which of the following is a possible cause for a pump failing to prime or losing prime, as indicated on the compound gauge?

<p>There are air leaks at the suction connections or in the suction hose (C)</p> Signup and view all the answers

What should be done if a reading of at least 10 inches of mercury is not reached within 45 seconds?

<p>Stop and check the pump for leaks (B)</p> Signup and view all the answers

Where should the suction be connected on the apparatus for safety consideration during the pump test at the draft site?

<p>Officer's side intake (B)</p> Signup and view all the answers

According to NFPA 1911, what is the formula for calculating the net pump pressure (NPP) when pumping from a hydrant?

<p>NPP = DP - IP (D)</p> Signup and view all the answers

What is the formula for calculating dynamic suction lift (DSL) in psi for a 1000 gpm pump with 20 ft of 5" hard suction?

<p>DSL = Lift + 9 + 1/2.31 (A)</p> Signup and view all the answers

On the 200 psi test for a 1500 gpm pump with a 2" tip, what is the discharge pressure?

<p>193 psi (C)</p> Signup and view all the answers

Which department should receive the original copy of the document?

<p>Apparatus Officer (C)</p> Signup and view all the answers

According to the text, how many copies of the document should be submitted to the company's battalion chief?

<p>1 (A)</p> Signup and view all the answers

What equipment is needed according to the text?

<p>Both of the above (C)</p> Signup and view all the answers

How many 50' lengths of high-pressure hoseline are needed for 1500 gpm pumpers?

<p>7 (C)</p> Signup and view all the answers

What should be used to straighten the stream of the master stream devices?

<p>Both of the above (C)</p> Signup and view all the answers

More Like This

Class 9th Annual Examination 2024 Subject
4 questions
Annual Clean-Up Day Quiz
2 questions
Annual Security Refresher Quiz
15 questions
Use Quizgecko on...