ANNUAL PUMP TEST 23
20 Questions
0 Views

ANNUAL PUMP TEST 23

Created by
@DextrousAlexandrite

Questions and Answers

According to the policy, when will pumpers be tested annually?

  • On the first Monday in March (correct)
  • On the first Monday in June
  • On the first Monday in May
  • On the first Monday in April
  • Who is responsible for testing the pumpers on an annual basis?

  • The Fire Commissioner
  • The Training Division (correct)
  • The Company Officer
  • The Apparatus Officer
  • What is the purpose of the pre-test check before a pump test is performed?

  • To engage the priming pump
  • To check the priming capability of the pumper (correct)
  • To observe the compound gauge
  • To check the oil level in the priming tank
  • According to the text, what is the minimum depth to which the suction strainer should be submerged?

    <p>2 feet</p> Signup and view all the answers

    What should be the reading on the master pump pressure gauge when the pump is primed?

    <p>50 psi</p> Signup and view all the answers

    What is the net pump pressure required to provide a 700 gpm discharge with a 2-1/2" high-pressure hoseline and a 1-3/4" tip?

    <p>200 psi</p> Signup and view all the answers

    Which valve must be tested before disconnecting hoselines from the apparatus?

    <p>Relief valve</p> Signup and view all the answers

    What is the purpose of opening the drains on relief valves with drains?

    <p>To clean the relief valve strainers</p> Signup and view all the answers

    What is the minimum flow rate required for the tank-to-pump valve test?

    <p>500 gpm</p> Signup and view all the answers

    Which of the following is a possible cause for a pump failing to prime or losing prime, as indicated on the compound gauge?

    <p>There are air leaks at the suction connections or in the suction hose</p> Signup and view all the answers

    What should be done if a reading of at least 10 inches of mercury is not reached within 45 seconds?

    <p>Stop and check the pump for leaks</p> Signup and view all the answers

    Where should the suction be connected on the apparatus for safety consideration during the pump test at the draft site?

    <p>Officer's side intake</p> Signup and view all the answers

    According to NFPA 1911, what is the formula for calculating the net pump pressure (NPP) when pumping from a hydrant?

    <p>NPP = DP - IP</p> Signup and view all the answers

    What is the formula for calculating dynamic suction lift (DSL) in psi for a 1000 gpm pump with 20 ft of 5" hard suction?

    <p>DSL = Lift + 9 + 1/2.31</p> Signup and view all the answers

    On the 200 psi test for a 1500 gpm pump with a 2" tip, what is the discharge pressure?

    <p>193 psi</p> Signup and view all the answers

    Which department should receive the original copy of the document?

    <p>Apparatus Officer</p> Signup and view all the answers

    According to the text, how many copies of the document should be submitted to the company's battalion chief?

    <p>1</p> Signup and view all the answers

    What equipment is needed according to the text?

    <p>Both of the above</p> Signup and view all the answers

    How many 50' lengths of high-pressure hoseline are needed for 1500 gpm pumpers?

    <p>7</p> Signup and view all the answers

    What should be used to straighten the stream of the master stream devices?

    <p>Both of the above</p> Signup and view all the answers

    More Quizzes Like This

    Class 9th Annual Examination 2024 Subject
    4 questions
    Annual Clean-Up Day Quiz
    2 questions
    Annual Leave Policies Overview
    24 questions
    Use Quizgecko on...
    Browser
    Browser