What is the primary purpose of checking the hour meter readings in a diesel generator set?

  • To test the auto-start feature in case of AC failure
  • To check the battery voltage
  • To determine the fuel efficiency of the generator
  • To schedule maintenance activities accordingly (correct)
  • What is the recommended earth resistance value for the earthing system?

  • Less than 1 ohm (correct)
  • Exactly 1 ohm
  • More than 1 ohm
  • Less than 5 ohms
  • What is the purpose of simulating a fire situation in the fire alarm system maintenance?

  • To check the earthing system's integrity
  • To ensure the air conditioners are working properly
  • To clean the fire sensors
  • To test the fire panels' reporting and analysis capabilities (correct)
  • What is an essential aspect of diesel generator set maintenance?

    <p>Testing on load</p> Signup and view all the answers

    Why is it necessary to check the battery voltage in diesel generator set maintenance?

    <p>To ensure the self-starting capability of the generator</p> Signup and view all the answers

    What is a crucial aspect of air conditioning maintenance?

    <p>Testing the changeover arrangement</p> Signup and view all the answers

    What is the primary objective of earthing system maintenance?

    <p>To prevent electrical shocks and ensure safety</p> Signup and view all the answers

    What is an essential activity in fire alarm system maintenance?

    <p>Cleaning the fire sensors</p> Signup and view all the answers

    What is the frequency of checking the proper functioning of external alarms in an indoor location?

    <p>Yearly</p> Signup and view all the answers

    Who is responsible for verifying the maintenance details during annual inspections?

    <p>Officer in-charge</p> Signup and view all the answers

    What is the frequency of maintenance for air conditioning in an indoor location?

    <p>Yearly</p> Signup and view all the answers

    What is the frequency of checking the earthing system in an indoor location?

    <p>Yearly</p> Signup and view all the answers

    What is the frequency of performing a bit error test on spare time slot/tributary?

    <p>Yearly</p> Signup and view all the answers

    What is the frequency of testing the fire alarm system in an indoor location?

    <p>Yearly</p> Signup and view all the answers

    Where should testing instruments be provided?

    <p>At a centralized location</p> Signup and view all the answers

    What is the frequency of maintenance for diesel generator sets in an indoor location?

    <p>Yearly</p> Signup and view all the answers

    What is the purpose of the alarm system?

    <p>To localize faults to a particular card or sub-system</p> Signup and view all the answers

    Who is responsible for checking the power supply equipment in an indoor location?

    <p>ADSTE/DSTE/Sr.DSTE</p> Signup and view all the answers

    What is the purpose of periodical checks and preventive maintenance?

    <p>To ensure the availability of network</p> Signup and view all the answers

    What type of testing facility should a PCM test set have?

    <p>A to A, A to D, D to A, D to D</p> Signup and view all the answers

    What type of record should be maintained for faults?

    <p>A record of the card, time of failure, duration of failure, and action taken</p> Signup and view all the answers

    How often should the clock frequency be checked?

    <p>Yearly</p> Signup and view all the answers

    What is the minimum duration for which a bit error test on spare time slot/tributary should be performed?

    <p>A week</p> Signup and view all the answers

    What is the primary purpose of the troubleshooting manual?

    <p>To provide a step-by-step procedure for localization of faults</p> Signup and view all the answers

    What is the unit of measurement for 'Total Voltage at Battery' in the Battery Set maintenance checks?

    <p>V</p> Signup and view all the answers

    What is the frequency of checking the 'Engine oil level' in the Diesel Generator Set maintenance checks?

    <p>Frequency not specified</p> Signup and view all the answers

    What is the purpose of the 'Simulation of fire by applying smoke' in the Fire Alarm Check Data List?

    <p>To test the fire alarm system</p> Signup and view all the answers

    What is the unit of measurement for the 'Earth pit' in the Earthing Check Data List?

    <p>Ohms</p> Signup and view all the answers

    What is the purpose of 'Watering of pits' in the Earthing Check Data List?

    <p>To maintain the earth pit's integrity</p> Signup and view all the answers

    What is the purpose of the 'Auto changeover' check in the Air Conditioner Check Data List?

    <p>To ensure the air conditioner's automatic switching</p> Signup and view all the answers

    What is the frequency of checking the 'Cell voltage' in the Battery Set maintenance checks?

    <p>Frequency not specified</p> Signup and view all the answers

    What is the purpose of the 'Checking of protection (X, Y & Z)' in the Battery Charger maintenance checks?

    <p>To check the battery's protection systems</p> Signup and view all the answers

    What is a recommended precaution when handling electronic components?

    <p>Touching a grounded metal surface to discharge static from your body</p> Signup and view all the answers

    What is the recommended frequency for checking the voltage in a multiplexing system?

    <p>3 monthly</p> Signup and view all the answers

    What is the purpose of electro statically sealing the PCB before transporting it to the repair center?

    <p>To prevent electrostatic discharge</p> Signup and view all the answers

    What is the recommended frequency for checking the total distortion in a multiplexing system?

    <p>Yearly</p> Signup and view all the answers

    What is the purpose of using antistatic flooring in a multiplexing system?

    <p>To prevent electrostatic discharge</p> Signup and view all the answers

    What is the recommended frequency for checking the alarm in a multiplexing system?

    <p>3 monthly</p> Signup and view all the answers

    What is the purpose of following a maintenance schedule for multiplexing equipment?

    <p>To prevent equipment failure</p> Signup and view all the answers

    What is the recommended standard for measurements in a multiplexing system?

    <p>All of the above</p> Signup and view all the answers

    What is the primary reason for following a maintenance schedule for multiplexing equipment?

    <p>To reduce equipment downtime and increase overall reliability</p> Signup and view all the answers

    What is the recommended frequency for checking the voltage in a multiplexing system?

    <p>3 monthly</p> Signup and view all the answers

    What is the purpose of using antistatic flooring in a multiplexing system?

    <p>To prevent static electricity from damaging equipment</p> Signup and view all the answers

    What is the recommended frequency for checking the total distortion in a multiplexing system?

    <p>Yearly</p> Signup and view all the answers

    What is the purpose of electro statically sealing the PCB before transporting it to the repair center?

    <p>To prevent damage from static electricity</p> Signup and view all the answers

    What is the recommended standard for measurements in a multiplexing system?

    <p>All of the above</p> Signup and view all the answers

    What is the purpose of alarm checks in a multiplexing system?

    <p>To detect faults in the system</p> Signup and view all the answers

    What is the recommended frequency for checking the idle channel noise in a multiplexing system?

    <p>6 monthly</p> Signup and view all the answers

    What is the minimum system availability required for the Indian Railways Telecom system?

    <p>99.5%</p> Signup and view all the answers

    What is the frame structure of the 2048 Kbps tributary based on?

    <p>ITU-T Rec. G.704</p> Signup and view all the answers

    What is the purpose of time slot 0 in the frame structure of the 2048 Kbps tributary?

    <p>Transmission of frame synchronization word and alarms</p> Signup and view all the answers

    What is the purpose of automatically switching over from one timing signal source to another in case of failure of primary source?

    <p>To ensure synchronization as per approved scheme</p> Signup and view all the answers

    What is the measurement of performance parameters made during the life cycle of the equipment based on?

    <p>Acceptable limits</p> Signup and view all the answers

    What is the purpose of advising S&T control before taking up any maintenance work on telecom equipment?

    <p>To ensure that signalling gears also run on common telecom equipment</p> Signup and view all the answers

    What is the primary requirement for the NMS in terms of management capabilities?

    <p>To check the current status of AC/DC input voltage of each SDH system</p> Signup and view all the answers

    What is the characteristics of complete circuit measured on the basis of?

    <p>Audio frequency 4W/2W interface</p> Signup and view all the answers

    What is the recommended frequency for joint testing of protection channels?

    <p>Once in three months</p> Signup and view all the answers

    What is the multi-frame structure of the 2048 Kbps tributary based on?

    <p>16 consecutive frames numbered from 0 to 15</p> Signup and view all the answers

    What is the primary objective of automatic protection switching?

    <p>To ensure fast restoration of services in case of failure</p> Signup and view all the answers

    What is the primary function of a Terminal MUX?

    <p>To multiplex 30 analogue and/or data channels to a 2048 Kbps digital stream</p> Signup and view all the answers

    What is the minimum number of 2048 Kbps ports required in a PRIMARY DROP/INSERT MUX?

    <p>Two</p> Signup and view all the answers

    What is the requirement for synchronization in SDH equipment?

    <p>Deriving timing signal from internal, external and incoming digital signal tributaries</p> Signup and view all the answers

    What is the upcoming technology for all new work in digital multiplexing equipment?

    <p>IP-MPLS</p> Signup and view all the answers

    What is the primary responsibility of the SSE/JE in terms of maintenance?

    <p>To maintain close liaison with Engineers/Managers of RailTel Corporation of India</p> Signup and view all the answers

    What is the primary requirement for the installation of SDH equipment?

    <p>To follow the guidelines described in para 14.3.8</p> Signup and view all the answers

    What type of cable is used in 25 KV AC electrified areas for media of transmission?

    <p>Star quad cable</p> Signup and view all the answers

    What is the function of DROP/INSERT MUX WITH CONFERENCE FACILITY?

    <p>To provide at least 3 party conferences between any combination of time slots</p> Signup and view all the answers

    What is the primary purpose of revertive systems in protection switching?

    <p>To automatically switch back to the original circuits after restoration of defect</p> Signup and view all the answers

    What is the transmission rate of SDH (STM-1) based hierarchy?

    <p>2048 Kbps</p> Signup and view all the answers

    What is the primary requirement for the system in terms of management capabilities?

    <p>To have management capabilities as per ITU-T G.831</p> Signup and view all the answers

    What is the primary purpose of using Radio based communication as a media of transmission?

    <p>To provide a transmission path in areas where cable installation is not feasible</p> Signup and view all the answers

    What is the primary advantage of using Optical fibre as a media of transmission?

    <p>Higher security</p> Signup and view all the answers

    What is the primary purpose of performing a bit error test on spare time slot/tributary for a period of at least one week?

    <p>To ensure the tributary is functioning correctly</p> Signup and view all the answers

    What is the main advantage of maintaining a systematic record of faults in the multiplexing system?

    <p>It helps in localizing the faults to a particular card or sub-system</p> Signup and view all the answers

    What type of testing facility should a PCM test set have in a multiplexing system?

    <p>A to A, A to D, D to A, D to D testing</p> Signup and view all the answers

    What is the primary function of the alarm system in a multiplexing system?

    <p>To detect and localize faults in the system</p> Signup and view all the answers

    What is the recommended location for providing testing instruments in a multiplexing system?

    <p>At a centralized location</p> Signup and view all the answers

    What is the frequency of performing a bit error test on spare time slot/tributary in a multiplexing system?

    <p>Yearly</p> Signup and view all the answers

    What is the primary purpose of the troubleshooting manual in a multiplexing system?

    <p>To provide a step-by-step procedure for fault localization</p> Signup and view all the answers

    What is the main benefit of maintaining a systematic record of faults in a multiplexing system?

    <p>It facilitates efficient troubleshooting and fault localization</p> Signup and view all the answers

    Study Notes

    Indoor Location Maintenance

    • Every indoor location requires maintenance for electronics, power supply equipment, and other equipment yearly.
    • The officer in-charge should verify the maintenance details during their annual inspections.

    Section Incharge Maintenance

    • The section in-charge is responsible for maintenance of electronics, power supply equipment, and other equipment at various frequencies:
      • Monthly: electronics, power supply equipment
      • Quarterly: DG set, air-conditioning, fire alarm system, general upkeep of equipment room
      • Half yearly: earth
      • Yearly: testing of alarms and its appearance on NMS

    Periodical Checks and Preventive Maintenance

    • Preventive maintenance is necessary for indoor and outdoor equipment to ensure proper upkeep and availability of the network.
    • Diesel Generator Set (DG set) maintenance includes:
      • Testing on load
      • Testing of auto-start in case of AC failure
      • Checking of hour meter readings
      • Checking of diesel oil/engine oil level
      • Checking of oil/air filters
      • Battery voltage (self-start)
      • Cleanliness
      • Water level (in radiator) if applicable
      • Any other check prescribed in the manual
    • Air Conditioning maintenance includes:
      • Working of the air conditioners
      • Working of changeover arrangement, if provided
    • Earthing maintenance includes:
      • Watering of the pits
      • Checking integrity/continuity of the physical connections
      • Tightening of nuts/bolts
      • Checking of earth resistance (value should be less than 1 ohm preferably)
    • Fire Alarm System maintenance includes:
      • Cleaning of fire sensors
      • Simulating the fire situation by applying smoke near to sensors
      • Checking the fire panels for reports and analysis

    General Upkeep of Co-located Equipment

    • Ensure cleanliness
    • Ensure the tower maintenance is done as per schedule by the nominated agency

    Failures

    • The alarm system helps localize faults to a particular card or sub-system.
    • A systematic record of faults must be maintained, indicating the details of the card, time of failure, duration of failure, and action taken to rectify the faults.

    Test Instruments

    • Testing instruments are to be provided at a centralized place or with the maintenance gang.
    • Equipment to be provided at the centralized location includes:
      • PCM test set with facility for A to A and A to D, D to A, D to D testing

    Annexure A: Power Supply Check Data List

    • The list includes items to be checked, frequencies, units, and dates for:
      • Battery Charger
      • Battery Set
      • Diesel Generator Set

    Annexure B: Air Conditioner Check Data List

    • The list includes items to be checked, frequencies, units, and dates for:
      • Cleaning air filter
      • Cooling
      • Load current
      • Cable connections
      • Auto changeover
      • Overhauling

    Annexure C: Fire Alarm Check Data List

    • The list includes items to be checked, frequencies, units, and dates for:
      • Cleaning of sensors
      • Simulation of fire by applying smoke
      • Checking of alarm system

    Annexure D: Earthing Check Data List

    • The list includes items to be checked, frequencies, units, and dates for:
      • Watering of pits wherever necessary
      • Verification of connections
      • Measurement of earth resistance

    Annexure E: Maintenance Format for Fibre Optic System

    • The format includes items to be checked, maintainer, sectional supervisor, and supervisor in charge for:
      • Network Management System
      • Optical Terminal Equipment
      • Maintenance schedule for multiplexing equipment

    System Availability and Performance

    • System availability shall be at least 99.5%.
    • Characteristics of complete circuit shall be measured based on audio frequency 4W/2W interface, following ITU-T G.712 standards.
    • Performance parameters shall be measured during equipment lifecycle, within acceptable limits.

    Synchronization

    • Equipment shall have provision for deriving timing signals from internal, external, and incoming digital signal tributaries.
    • Automatic switching from one timing signal source to another shall occur in case of primary source failure.
    • Synchronization shall be ensured, following approved scheme.

    Frame Structure

    • Frame structure shall conform to ITU-T Rec. G.704/G.732.
    • Frame consists of 32 time slots (0-31), with time slot 0 for transmission of frame synchronization word and alarms.
    • Time slot 16 is for transmission of signalling of channels 1-15 and 16-31.

    Fault Condition and Consequent Action

    • Precautions to be taken while handling electronic components to avoid static discharge.
    • Safety instructions provided by the manufacturer shall be followed.
    • Maintenance schedule for multiplexing equipment shall be followed, with measurements carried out in line with relevant ITU-T standards.

    Maintenance

    • SSE/JE shall maintain close liaison with Engineers/Managers of RailTel Corporation of India (RCIL) for proper maintenance of SDH equipment.
    • Joint testing of protection channels shall be carried out by RailTel and field staff every three months.
    • System shall have provision for manual selection of clock.

    Test Instruments

    • Testing instruments shall be provided at a centralized place or with the maintenance gang.
    • PCM test set with facility for A to A and A to D, D to A, D to D testing shall be provided.

    Digital Multiplexing Equipment

    • Existing digital multiplexing equipment are based on 2048 Kbps SDH (STM-1, STM-4, STM-16 or higher) 10 Mbps, 100 Mbps, 1 Gbps (Ethernet) based hierarchy.
    • New work shall be based on IP-MPLS technology.
    • Media of transmission includes symmetric cable pairs/HDSL modems, star quad cable in 25 KV AC electrified areas, optical fibre, and radio-based communication.

    Primary Multiplexing Equipment

    • Primary multiplexing equipment shall multiplex 30 analogue and/or data channels to 2048 Kbps ITU compatible digital stream on transmit side.
    • On receive side, it shall demultiplex ITU compatible 2048 Kbps digital stream to 30 analogue voice/data channels.
    • Types of primary multiplexers include terminal MUX, primary drop/insert MUX, and drop/insert MUX with conference facility.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Related Documents

    Description

    Quiz about yearly maintenance of primary MUX circuits, including clock frequency, bit error tests, and alarm systems for fault localization.

    More Like This

    Use Quizgecko on...
    Browser
    Browser