The maximum water consumption flow rates and quantities for all plumbing fixtures and fixture fittings shall be in accordance with Table ______
The maximum water consumption flow rates and quantities for all plumbing fixtures and fixture fittings shall be in accordance with Table ______
604.4
A hand-held shower spray is a type of ______
A hand-held shower spray is a type of ______
shower head
Blowout design water closets should have a water consumption not greater than ______ gallons per flushing cycle
Blowout design water closets should have a water consumption not greater than ______ gallons per flushing cycle
31/2
Clinical sinks should have a water consumption not greater than ______ gallons per flushing cycle
Clinical sinks should have a water consumption not greater than ______ gallons per flushing cycle
Signup and view all the answers
The minimum size of a fixture supply pipe shall be as shown in Table ______
The minimum size of a fixture supply pipe shall be as shown in Table ______
Signup and view all the answers
The supply pipe shall terminate not more than ______ inches from the point of connection to the fixture
The supply pipe shall terminate not more than ______ inches from the point of connection to the fixture
Signup and view all the answers
For Residential Buildings to serve larger number of people, allocate liquid per person – ______ to ______ cum
For Residential Buildings to serve larger number of people, allocate liquid per person – ______ to ______ cum
Signup and view all the answers
For small residential house to serve up to 12 persons, the chamber should have a liquid content of not more than - ______ cum
For small residential house to serve up to 12 persons, the chamber should have a liquid content of not more than - ______ cum
Signup and view all the answers
For school, commercial & industrial establishments, the volume of the septic tank should not be less than - ______ cum nor more than – ______ cum per person
For school, commercial & industrial establishments, the volume of the septic tank should not be less than - ______ cum nor more than – ______ cum per person
Signup and view all the answers
When large amount of water waste is coming from the shower, bath, laundry & others, it is not advisable to permit entry to these waters into septic tank. All downspout collecting water from the roof should not be allowed to terminate into the septic tank. Rainwater should be conveyed to the ______ drain.
When large amount of water waste is coming from the shower, bath, laundry & others, it is not advisable to permit entry to these waters into septic tank. All downspout collecting water from the roof should not be allowed to terminate into the septic tank. Rainwater should be conveyed to the ______ drain.
Signup and view all the answers
To determine the size of a septic tank to serve 200 persons in a commercial establishment, refer to the Technical Data of information. For a commercial establishment, we find a value of ______ cum.
To determine the size of a septic tank to serve 200 persons in a commercial establishment, refer to the Technical Data of information. For a commercial establishment, we find a value of ______ cum.
Signup and view all the answers
Assume 1.2 meters width of the tank per 100 persons. For 200 individuals multiply: 200 persons x 1.2 m = ______ width
Assume 1.2 meters width of the tank per 100 persons. For 200 individuals multiply: 200 persons x 1.2 m = ______ width
Signup and view all the answers
The minimum size of individual distribution lines for ______ systems shall be as shown in Table 604.5. Where the developed length of the distribution line is 50 feet or less, and the available pressure at the meter is 35 psi or greater, the minimum size of an individual distribution line supplied from a manifold and installed as part of a parallel ______ distribution system shall be one nominal tube size smaller than the sizes indicated.
The minimum size of individual distribution lines for ______ systems shall be as shown in Table 604.5. Where the developed length of the distribution line is 50 feet or less, and the available pressure at the meter is 35 psi or greater, the minimum size of an individual distribution line supplied from a manifold and installed as part of a parallel ______ distribution system shall be one nominal tube size smaller than the sizes indicated.
Signup and view all the answers
Variable Street Pressures: Where street water main pressures fluctuate, the building water distribution system shall be designed for the minimum ______ available.
Variable Street Pressures: Where street water main pressures fluctuate, the building water distribution system shall be designed for the minimum ______ available.
Signup and view all the answers
Inadequate Water Pressure: Wherever water pressure from the street main or other source of supply is insufficient to provide flow pressures at fixture outlets as required under Table 604.3, a water pressure booster system conforming to Section 606.5 shall be installed on the building water supply ______.
Inadequate Water Pressure: Wherever water pressure from the street main or other source of supply is insufficient to provide flow pressures at fixture outlets as required under Table 604.3, a water pressure booster system conforming to Section 606.5 shall be installed on the building water supply ______.
Signup and view all the answers
Water Pressure-Reducing Valve or Regulator: Where water pressure within a building exceeds 80 psi (552 kPa) static, an approved water pressure-reducing ______ conforming to ASSE 1003 or CSA B356 with strainer shall be installed to reduce the pressure in the building water distribution piping to not greater than 80 psi (552 kPa) static.
Water Pressure-Reducing Valve or Regulator: Where water pressure within a building exceeds 80 psi (552 kPa) static, an approved water pressure-reducing ______ conforming to ASSE 1003 or CSA B356 with strainer shall be installed to reduce the pressure in the building water distribution piping to not greater than 80 psi (552 kPa) static.
Signup and view all the answers
The minimum size of individual distribution lines utilized in gridded or parallel water distribution systems shall be as shown in Table 604.5. Where the developed length of the distribution line is 50 feet or less, and the available pressure at the meter is 35 psi or greater, the minimum size of an individual distribution line supplied from a manifold and installed as part of a parallel water distribution system shall be one nominal tube size smaller than the sizes ______.
The minimum size of individual distribution lines utilized in gridded or parallel water distribution systems shall be as shown in Table 604.5. Where the developed length of the distribution line is 50 feet or less, and the available pressure at the meter is 35 psi or greater, the minimum size of an individual distribution line supplied from a manifold and installed as part of a parallel water distribution system shall be one nominal tube size smaller than the sizes ______.
Signup and view all the answers
Where street water main pressures fluctuate, the building water distribution system shall be designed for the minimum pressure ______.
Where street water main pressures fluctuate, the building water distribution system shall be designed for the minimum pressure ______.
Signup and view all the answers