RROW Allowed Uses Quiz

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson
Download our mobile app to listen on the go
Get App

Questions and Answers

What are the allowed uses within the Right of Way (RROW) related to transportation structures?

  • Long-term vehicle parking
  • Government structures
  • Residential structures
  • Waiting sheds (correct)

Which of the following is an improvement allowed on the RROW?

  • Stalled vehicle depository
  • Elevated or underground crossings (correct)
  • Unauthorized recreational usage
  • Residential structures

What is NOT a suggested RROW width for access to property?

  • 4.00m (correct)
  • 1.50m
  • 2.00m
  • 3.00m

Which of the following is a prohibited use within the RROW?

<p>Unauthorized recreational usage (B)</p> Signup and view all the answers

Which type of structures are allowed within the RROW for public utility/service purposes?

<p>Water structures (C)</p> Signup and view all the answers

What kind of structures are government structures allowed to be within the RROW?

<p>Below grade structures (B)</p> Signup and view all the answers

According to the rule, how high above the sidewalk grade must Arcades be constructed?

<p>3.00m (D)</p> Signup and view all the answers

What is the minimum width required for a chaflan on a corner building on a public street?

<p>4.00m (C)</p> Signup and view all the answers

In accordance with the rule, what activity is not permitted on public streets?

<p>Mortar mixing (C)</p> Signup and view all the answers

What is the minimum width requirement for a temporary walkway when a sidewalk is authorized to be closed?

<p>1.20m (C)</p> Signup and view all the answers

According to the rule, how much should a door or window project beyond the property line when fully opened?

<p>2.40m (D)</p> Signup and view all the answers

What is the maximum width allowed for a chaflan on a corner building on a public street?

<p>3.60m (B)</p> Signup and view all the answers

What is the minimum width required for an aisle serving only one side?

<p>0.80m (D)</p> Signup and view all the answers

What is the maximum slope allowed for an aisle?

<p>1 in 8 (A)</p> Signup and view all the answers

What is the minimum back-to-back distance required for grandstand/bleacher seating with backrests?

<p>850mm (B)</p> Signup and view all the answers

What is the maximum number of seats allowed between any seat and an aisle in a grandstand/bleacher setup?

<p>15 (B)</p> Signup and view all the answers

When are automatic fire extinguishing systems required?

<p>Both b and c (A)</p> Signup and view all the answers

What is the minimum and maximum height above grade for Siamese connections on the street-front of a building?

<p>300mm-1200mm (C)</p> Signup and view all the answers

What is the maximum allowable length for a dead end corridor?

<p>6.00m (B)</p> Signup and view all the answers

What is the minimum required tread depth for stairs?

<p>250mm (D)</p> Signup and view all the answers

For a stairway with an occupant load greater than 50, what is the minimum required width?

<p>1.10m (C)</p> Signup and view all the answers

What is the maximum allowable reduction in stairway width caused by handrails?

<p>100mm (B)</p> Signup and view all the answers

Which type of stairway is allowed to have only one handrail?

<p>Both A and C (B)</p> Signup and view all the answers

What is the maximum allowable vertical distance between stair landings?

<p>3.60m (D)</p> Signup and view all the answers

What documentation is required for the use of computers for building design?

<p>Detailed description of the program's algorithms (D)</p> Signup and view all the answers

According to the rules, how should signs in a foreign language be displayed?

<p>With a translation in English or the local dialect (C)</p> Signup and view all the answers

What is the maximum projection allowed for signs on non-arcaded RROW?

<p>1.20 meters (D)</p> Signup and view all the answers

Where should ground signs be located?

<p>Within the property line (A)</p> Signup and view all the answers

What is the minimum vertical clearance required for projecting signs on arcaded RROW?

<p>5.00 meters (B)</p> Signup and view all the answers

What type of buildings are prohibited from having signs on their rooftops?

<p>Buildings with wooden structures (B)</p> Signup and view all the answers

Flashcards are hidden until you start studying

Use Quizgecko on...
Browser
Browser