What are the allowed uses within the Right of Way (RROW) related to transportation structures?

  • Long-term vehicle parking
  • Government structures
  • Residential structures
  • Waiting sheds (correct)
  • Which of the following is an improvement allowed on the RROW?

  • Stalled vehicle depository
  • Elevated or underground crossings (correct)
  • Unauthorized recreational usage
  • Residential structures
  • What is NOT a suggested RROW width for access to property?

  • 4.00m (correct)
  • 1.50m
  • 2.00m
  • 3.00m
  • Which of the following is a prohibited use within the RROW?

    <p>Unauthorized recreational usage</p> Signup and view all the answers

    Which type of structures are allowed within the RROW for public utility/service purposes?

    <p>Water structures</p> Signup and view all the answers

    What kind of structures are government structures allowed to be within the RROW?

    <p>Below grade structures</p> Signup and view all the answers

    According to the rule, how high above the sidewalk grade must Arcades be constructed?

    <p>3.00m</p> Signup and view all the answers

    What is the minimum width required for a chaflan on a corner building on a public street?

    <p>4.00m</p> Signup and view all the answers

    In accordance with the rule, what activity is not permitted on public streets?

    <p>Mortar mixing</p> Signup and view all the answers

    What is the minimum width requirement for a temporary walkway when a sidewalk is authorized to be closed?

    <p>1.20m</p> Signup and view all the answers

    According to the rule, how much should a door or window project beyond the property line when fully opened?

    <p>2.40m</p> Signup and view all the answers

    What is the maximum width allowed for a chaflan on a corner building on a public street?

    <p>3.60m</p> Signup and view all the answers

    What is the minimum width required for an aisle serving only one side?

    <p>0.80m</p> Signup and view all the answers

    What is the maximum slope allowed for an aisle?

    <p>1 in 8</p> Signup and view all the answers

    What is the minimum back-to-back distance required for grandstand/bleacher seating with backrests?

    <p>850mm</p> Signup and view all the answers

    What is the maximum number of seats allowed between any seat and an aisle in a grandstand/bleacher setup?

    <p>15</p> Signup and view all the answers

    When are automatic fire extinguishing systems required?

    <p>Both b and c</p> Signup and view all the answers

    What is the minimum and maximum height above grade for Siamese connections on the street-front of a building?

    <p>300mm-1200mm</p> Signup and view all the answers

    What is the maximum allowable length for a dead end corridor?

    <p>6.00m</p> Signup and view all the answers

    What is the minimum required tread depth for stairs?

    <p>250mm</p> Signup and view all the answers

    For a stairway with an occupant load greater than 50, what is the minimum required width?

    <p>1.10m</p> Signup and view all the answers

    What is the maximum allowable reduction in stairway width caused by handrails?

    <p>100mm</p> Signup and view all the answers

    Which type of stairway is allowed to have only one handrail?

    <p>Both A and C</p> Signup and view all the answers

    What is the maximum allowable vertical distance between stair landings?

    <p>3.60m</p> Signup and view all the answers

    What documentation is required for the use of computers for building design?

    <p>Detailed description of the program's algorithms</p> Signup and view all the answers

    According to the rules, how should signs in a foreign language be displayed?

    <p>With a translation in English or the local dialect</p> Signup and view all the answers

    What is the maximum projection allowed for signs on non-arcaded RROW?

    <p>1.20 meters</p> Signup and view all the answers

    Where should ground signs be located?

    <p>Within the property line</p> Signup and view all the answers

    What is the minimum vertical clearance required for projecting signs on arcaded RROW?

    <p>5.00 meters</p> Signup and view all the answers

    What type of buildings are prohibited from having signs on their rooftops?

    <p>Buildings with wooden structures</p> Signup and view all the answers