Podcast
Questions and Answers
If a large portion of a bar joist metal deck roof building is already heavily involved on arrival (__ % or more of large buildings) you may not be able to preform roof ventilation
If a large portion of a bar joist metal deck roof building is already heavily involved on arrival (__ % or more of large buildings) you may not be able to preform roof ventilation
50
For bar joist metal deck buildings what is needed is an evaluation of the extent of fire involvement, coupled with a _____ fire attack
For bar joist metal deck buildings what is needed is an evaluation of the extent of fire involvement, coupled with a _____ fire attack
Coordinated
You should start __ stores over from a fire store in row of attached stores, this way you can cool the unprotected steel joist
You should start __ stores over from a fire store in row of attached stores, this way you can cool the unprotected steel joist
3
In a metal deck roof fire, if there is not heavy fire in the contents below FFs on the roof will be needed to cut through the _____ and expose the burning tar. You only need to get the _____ up
In a metal deck roof fire, if there is not heavy fire in the contents below FFs on the roof will be needed to cut through the _____ and expose the burning tar. You only need to get the _____ up
When making the insulation cuts, initially pull up a relatively small section (___ ft) in order to determine which way the corrugating runs
When making the insulation cuts, initially pull up a relatively small section (___ ft) in order to determine which way the corrugating runs
After finding which way the corrugating runs then make long __ ft wide strips _____ to the corrugation to open as many little valleys as possible
After finding which way the corrugating runs then make long __ ft wide strips _____ to the corrugation to open as many little valleys as possible
The ____and cooling power of the 2 1/2 in hose will be helpful here, especially in many of the high ceiling structures, such as _____ and big box type stores where this type of fire is most likely
The ____and cooling power of the 2 1/2 in hose will be helpful here, especially in many of the high ceiling structures, such as _____ and big box type stores where this type of fire is most likely
While most prevalent in new construction, lightweight construction is used in renovations due to the ____ and ease of installation
While most prevalent in new construction, lightweight construction is used in renovations due to the ____ and ease of installation
As a guide whether to send in FFs in occupied lightweight structures try to determine wether fire has penetrated ___ attacking the trusses
As a guide whether to send in FFs in occupied lightweight structures try to determine wether fire has penetrated ___ attacking the trusses
Opening up a buildings ____ and directing a stream into the truss loft may be quite useful
Opening up a buildings ____ and directing a stream into the truss loft may be quite useful
If a life hazard is known or suspected efforts should be coordinated to provide the ____, most direct approach to that location without placing FFs in undue danger
If a life hazard is known or suspected efforts should be coordinated to provide the ____, most direct approach to that location without placing FFs in undue danger
On larger buildings where vertical ventilation is deemed to dangerous _____ ventilation from a platform basket may suffice
On larger buildings where vertical ventilation is deemed to dangerous _____ ventilation from a platform basket may suffice
After the fire is knocked down, place the emphasis on ____ the structure
After the fire is knocked down, place the emphasis on ____ the structure
Proceed slowly when assessing the structure providing ____ window ventilation and maximum ____
Proceed slowly when assessing the structure providing ____ window ventilation and maximum ____
Operate with the absolute _____ of personnel in the danger area until the trusses or other lightweight elements have been exposed and examined
Operate with the absolute _____ of personnel in the danger area until the trusses or other lightweight elements have been exposed and examined
Provide emergency ____ as necessary in the building
Provide emergency ____ as necessary in the building
Sweeping the ceiling with large streams also helps reduce the ___ problem with metal deck roofs— the metal deck roof fire. This can occur without any major involvement of the items directly below and can result in the extension of fire over the heads of FFs who assume all is under contr
Sweeping the ceiling with large streams also helps reduce the ___ problem with metal deck roofs— the metal deck roof fire. This can occur without any major involvement of the items directly below and can result in the extension of fire over the heads of FFs who assume all is under contr
It is critical that FFs identify such construction while it is in ____, before the fire; _____ it for future reference and _____ its presence to every possible responding ff. _____ officers must establish policies for operations at such structures
It is critical that FFs identify such construction while it is in ____, before the fire; _____ it for future reference and _____ its presence to every possible responding ff. _____ officers must establish policies for operations at such structures
Flashcards
Coordinated Fire Attack
Coordinated Fire Attack
For bar joist metal deck buildings a coordinated fire attack is necessary to control the fire.
50% Fire Involvement
50% Fire Involvement
If 50% or more of a large bar joist metal deck roof building is engulfed in flames, it is likely unsafe to attempt roof ventilation.
Attack 3 Stores Over
Attack 3 Stores Over
Start attacking stores 3 over from the initial fire store, this allows you to cool the unprotected steel joists in a line of stores.
Cutting Through Insulation
Cutting Through Insulation
Signup and view all the flashcards
Initial Insulation Cut
Initial Insulation Cut
Signup and view all the flashcards
2 ft Strips
2 ft Strips
Signup and view all the flashcards
Hose Reach and Cooling
Hose Reach and Cooling
Signup and view all the flashcards
Lightweight Construction - Renovations
Lightweight Construction - Renovations
Signup and view all the flashcards
Lightweight Structure Fire Assessment
Lightweight Structure Fire Assessment
Signup and view all the flashcards
Sidewall Ventilation
Sidewall Ventilation
Signup and view all the flashcards
Safest Rescue Approach
Safest Rescue Approach
Signup and view all the flashcards
Horizontal Ventilation
Horizontal Ventilation
Signup and view all the flashcards
Structural Assessment
Structural Assessment
Signup and view all the flashcards
Cautious Assessment
Cautious Assessment
Signup and view all the flashcards
Minimum Personnel Risk
Minimum Personnel Risk
Signup and view all the flashcards
Emergency Shoring
Emergency Shoring
Signup and view all the flashcards