What is the purpose of adding bolus to the skin when using MV photons?
What is the purpose of adding bolus to the skin when using MV photons?
Which of the following is NOT a criterion for selecting the ICRU Reference Point?
Which of the following is NOT a criterion for selecting the ICRU Reference Point?
Where should the target absorbed dose be specified for a single beam?
Where should the target absorbed dose be specified for a single beam?
For parallel opposed, unequally weighted beams, where should the target dose be specified?
For parallel opposed, unequally weighted beams, where should the target dose be specified?
Signup and view all the answers
In what scenario should the target dose specification point be at the intersection of beam axes?
In what scenario should the target dose specification point be at the intersection of beam axes?
Signup and view all the answers
What is a primary advantage of using parallel opposed fields in radiotherapy?
What is a primary advantage of using parallel opposed fields in radiotherapy?
Signup and view all the answers
What disadvantage is associated with parallel opposed fields?
What disadvantage is associated with parallel opposed fields?
Signup and view all the answers
In tangential beam therapy for breast treatment, what is primarily prevented?
In tangential beam therapy for breast treatment, what is primarily prevented?
Signup and view all the answers
What is the primary purpose of creating a set of beams in the planning process?
What is the primary purpose of creating a set of beams in the planning process?
Signup and view all the answers
Wedges are required in tangential fields to achieve what?
Wedges are required in tangential fields to achieve what?
Signup and view all the answers
Which of the following criteria is NOT used for assessing the acceptability of a single beam treatment?
Which of the following criteria is NOT used for assessing the acceptability of a single beam treatment?
Signup and view all the answers
In which situation is a single megavoltage beam typically used?
In which situation is a single megavoltage beam typically used?
Signup and view all the answers
What is a characteristic feature of highly wedged beams?
What is a characteristic feature of highly wedged beams?
Signup and view all the answers
Why might a lightly weighted third field be beneficial in parotid treatments?
Why might a lightly weighted third field be beneficial in parotid treatments?
Signup and view all the answers
What is the major disadvantage of using a single field technique?
What is the major disadvantage of using a single field technique?
Signup and view all the answers
What is a common practice for treating skin cancers confined to a few millimeters of depth?
What is a common practice for treating skin cancers confined to a few millimeters of depth?
Signup and view all the answers
For PTVs located deeper in the patient, what configuration is most effective?
For PTVs located deeper in the patient, what configuration is most effective?
Signup and view all the answers
Parallel-opposed beams are defined as:
Parallel-opposed beams are defined as:
Signup and view all the answers
What is a potential consequence of using angled beams compared to parallel opposed fields?
What is a potential consequence of using angled beams compared to parallel opposed fields?
Signup and view all the answers
What initial decisions must be made early in the planning process?
What initial decisions must be made early in the planning process?
Signup and view all the answers
Why are single beam treatments generally not commonly used?
Why are single beam treatments generally not commonly used?
Signup and view all the answers
What is the mechanical isocenter in radiation therapy?
What is the mechanical isocenter in radiation therapy?
Signup and view all the answers
What is the primary goal of the field arrangement in radiation therapy?
What is the primary goal of the field arrangement in radiation therapy?
Signup and view all the answers
Why might the isocenter be set to predefined skin marks during treatment planning?
Why might the isocenter be set to predefined skin marks during treatment planning?
Signup and view all the answers
What is a key consideration when selecting beam energy for radiation therapy?
What is a key consideration when selecting beam energy for radiation therapy?
Signup and view all the answers
In the classical four-field technique, what shape is the region of tissue most commonly irradiated?
In the classical four-field technique, what shape is the region of tissue most commonly irradiated?
Signup and view all the answers
Which of the following is true regarding low energy beams?
Which of the following is true regarding low energy beams?
Signup and view all the answers
What distinguishes the four-field crossfire technique from the classical four-field technique?
What distinguishes the four-field crossfire technique from the classical four-field technique?
Signup and view all the answers
How does the placement of the isocenter affect dose computation accuracy?
How does the placement of the isocenter affect dose computation accuracy?
Signup and view all the answers
Why is the three-field technique generally preferred in specific areas?
Why is the three-field technique generally preferred in specific areas?
Signup and view all the answers
What is one reason to avoid using high energy beams (above 15 MV) frequently in treatment planning?
What is one reason to avoid using high energy beams (above 15 MV) frequently in treatment planning?
Signup and view all the answers
What is a characteristic of noncoplanar beams in radiation therapy?
What is a characteristic of noncoplanar beams in radiation therapy?
Signup and view all the answers
Which treatment strategy minimizes radiation dose to adjacent critical structures?
Which treatment strategy minimizes radiation dose to adjacent critical structures?
Signup and view all the answers
In which situation would the four-field technique be most appropriate?
In which situation would the four-field technique be most appropriate?
Signup and view all the answers
What role do wedges play in the three-field technique?
What role do wedges play in the three-field technique?
Signup and view all the answers
What is the function of the build-up region in MV beams?
What is the function of the build-up region in MV beams?
Signup and view all the answers
Why is it critical to ensure the gantry rotation axis is free of obstruction?
Why is it critical to ensure the gantry rotation axis is free of obstruction?
Signup and view all the answers
Study Notes
Treatment Field Design and Planning Technique
- The presentation covers techniques for designing and planning treatment fields in radiation therapy, particularly focused on various beam arrangements.
Defining Target and Critical Structures
- GTV (Gross Tumor Volume): The area encompassing the visible tumor.
- PTV (Planning Target Volume): A larger volume encompassing the GTV to account for tumor margins and uncertainties in patient movement.
- CTV (Clinical Target Volume): The target volume that includes the entire area where tumor can spread or recurr including healthy tissue.
Treatment Techniques
-
Single Beam Arrangement: Generally unsuitable unless the tumor is superficial, and criteria are met in terms of uniformity and dose limits to surrounding healthy tissue.
-
Parallel Opposed Beams: The simplest combination, where two beams are directed along the same axis from opposite sides.
- Advantages: Simpler setup; homogenous dose to the tumor; lesser chance of geometric errors if the field size is adequate.
- Disadvantages: Excessive dose to normal tissues; high dose regions; hour-glass contour and unacceptably low doses.
-
Tangential Beams: Commonly used in breast and chest wall treatments (post-mastectomy) to avoid lung divergence minimizing lung dose. Wedges often required for uniform PTV dose compensation for missing tissue and lung presence.
-
Multiple Coplanar Beams: Useful for deeper targets, ensuring best dose distribution, conforming closely to the PTV while minimizing normal tissue irradiation. Commonly used in advanced therapies like IMRT or VMAT. Four-field Technique: Two pairs of parallel-opposed beams at right angles, creating a box-shaped irradiation zone. Effective in areas where opposing surfaces are parallel, and target lies deep or midway between the inter-surface distance.
-
Multiple Noncoplanar Beams: Beams positioned at different angles (non-coplanar) to cover deep targets and minimize/avoid critical structures, such as the organs in the head and neck area. It's frequently used in treating CNS tumors and perineal irradiation.
Isocenter Position
- The isocenter is a crucial point in the body. The radiation beams pass through this point and the mechanical isocenter is a crucial reference point.
- The treatment plan's first step is to determine the isocenter position.
- While the tumor's center might be the default, practitioners frequently use predefined skin marks acquired during CT scanning for accurate positioning. These marks are commonly set on stable skin regions to ensure precise treatment delivery without steep body contouring variations. Isocenter positioning is frequently adjusted based on internal anatomy to minimize doses to critical structures, and avoid beam divergence, such as in treatments for the lung or abutting nodal fields.
- Accurate dose computation needs careful isocenter placement. The presence of the isocenter within a solid material, not an aircavity, often improves dose prediction accuracy.
Beam Energy
- The selected beam energy depends on the tumor depth and penetration properties.
- Lower energies (e.g., 4–6 MV) are often used for superficial tumors (e.g., head and neck).
- Higher energies (e.g., 10–20 MV) are needed for deep-seated tumors (e.g., pelvic). Higher energies, while offering benefits, can present protection challenges due to neutron production.
Build-up Region and Bolus
- The build-up region is a spatial area within the beams that is adjusted for optimal skin sparing by ensuring the highest dose is delivered close to the skin (not deep into or through) the body.
- Bolus can be added to shift the build-up region on the skin; this ensures more targeted and controlled irradiation close to the surface.
ICRU Reference Point
- The target dose should be designated at the ICRU reference point. A designated spot within the center or the central portion of the PTV fulfills ICRU specifications and is the generally recommended spot. When possible, It is situated at the intersection of beam axes. This point needs to be clear and clinically relevant—representative of the dose throughout the PTV. It needs to be easily defined for correct dose calculation, avoiding the penumbra (no sharp or abrupt doses) or steep gradients found in the area surrounding the isocenter.
Additional Notes
- The selection of a specific technique depends on the patient's anatomy, and the unique characteristics of the tumor.