Match the following radiation monitoring instruments with their descriptions:

Optically Stimulated Luminescence (OSL) = Can be re-analysed multiple times without losing sensitivity Self-reading Pocket Dosimeter = Resembles a pen and consists of an ionization chamber Electronic Personal Dosimeter = Offers real-time read-out of radiation exposure Direct Reading Personal Monitors = Used to track doses in day-to-day activities

Match the following dosimetric quantities with their definitions:

Air-Kerma = The kinetic energy of charged particles emitted from ionizing radiation Dose Equivalent = A dose measurement that accounts for the biological effect of radiation Exposure = The amount of ionization produced in air by X or gamma radiation Effective Dose = A measurement that accounts for the long-term effects of different types of radiation

Match the following individual monitoring techniques with their characteristics:

Passive Dosimetry = Utilizes badges to record radiation exposures over time Direct Reading Dosimetry = Provides immediate feedback on exposure levels Thermoluminescent Dosimetry = Uses crystalline materials to measure radiation exposure Film Dosimetry = Employs photographic films that darken with radiation exposure

Match the following characteristics with the appropriate radiation monitoring instruments:

<p>OSL Dosimeters = Wide dose range up to 10 Sv Self-reading Pocket Dosimeters = Prone to charge leakage and poor sensitivity Electronic Personal Dosimeters = More sensitive compared to older techniques Area Survey Meters = Used to measure radiation levels in specific locations</p> Signup and view all the answers

Match the following individual monitoring techniques with their descriptions:

<p>TLD dosimetry = Uses thermoluminescent materials to measure dose Film dosimetry = Photographic film that indicates radiation exposure Optically simulated luminescence (OSL) = Measures dose using light stimulation Radiophotoluminescence (RPL) = Uses a specific type of glass to determine dose</p> Signup and view all the answers

Match the following radiation monitoring instruments with their uses:

<p>Pocket dosimeter = Provides immediate dose readings Albedo dosimeter = Used for fast neutron dose measurements Ionization chamber = Measures radiation intensity Electronic personal dosimeter = Records both instantaneous and accumulated dose</p> Signup and view all the answers

Match the following areas with their significance in radiation monitoring:

<p>Area survey meters = Used for evaluating radiation levels in specific locations Individual monitoring techniques = Assess doses received by personnel Environmental monitoring = Measures radiation in the surrounding environment Quality assurance = Ensures measurement accuracy and reliability</p> Signup and view all the answers

Match the type of uncertainty with its description:

<p>Type A Uncertainty = Statistical uncertainty from repeated measurements Type B Uncertainty = Systematic uncertainty from external factors Combined Uncertainty = Result from combining Type A and Type B Coverage Factor = Defines confidence limits in measurements</p> Signup and view all the answers

Match the individual monitoring techniques with their purpose:

<p>Regular Monitoring = Ensures compliance with radiation safety standards Accidental Exposure Reporting = Documents incidents of overexposure Workplace Survey = Evaluates radiation levels in work areas Dose Verification = Confirms effectiveness of radiation control measures</p> Signup and view all the answers

Match the radiation type with its characteristic:

<p>Gamma Radiation = Highly penetrating electromagnetic radiation Beta Radiation = Consists of high-speed electrons or positrons Alpha Radiation = Contains helium nuclei and has low penetration X-ray Radiation = Similar to gamma but originates from atomic transitions</p> Signup and view all the answers

Match the properties of area survey meters with their details:

<p>Energy Dependence = Refers to how response changes with radiation energy Angular Dependence = Refers to response variations based on angle of incidence Calibration Conditions = Standards defined for instrument accuracy User Field Conditions = Real-world conditions differing from calibration settings</p> Signup and view all the answers

Match the confidence level with its associated coverage factor:

<p>95% Confidence = Coverage factor k = 2 99% Confidence = Coverage factor k = 3 68% Confidence = Coverage factor k = 1 Confidence Interval = Range within which the true value is expected to fall</p> Signup and view all the answers

Match the reasons for individual monitoring with their significance:

<p>Doses Monitored = Ensures safety for workers with radiation exposure Control Practices Verification = Assesses effectiveness of safety measures Radiation Level Changes Detection = Facilitates timely interventions Accidental Exposure Information = Supports investigations following incidents</p> Signup and view all the answers

Study Notes

Chapter 4: Radiation Monitoring Instruments

  • Objective: To familiarize students with instruments used for monitoring exposure from external radiation.
  • Author: G. Rajan, J. Izewska
  • Publication: Review of Radiation Oncology Physics: A Handbook for Teachers and Students (ISBN 92-0-107304-6)
  • Slide Set: 107 slides
  • Preparation Year: 2006
  • Preparation by: G.H. Hartmann (Heidelberg, DKFZ)
  • Comments to: S. Vatnitsky, [email protected]

4.1 Introduction

  • Radiation Exposure Classification: Internal and external exposure.
  • Chapter Focus: Only external exposures.
  • Aim of Monitoring: Measuring radiation levels in work areas, around therapy equipment/source containers, and dose equivalents for individuals.
  • Specific Needs: Area monitors for work areas and source containers. Personal monitors for individuals working with radiation.
  • Purpose of Results: Assess workplace conditions, individual exposures, and ensure safe radiological conditions for regulation and good practice.

4.2 Operational Quantities for Radiation Monitoring

  • Calibration: Instruments must be calibrated using appropriate quantities for radiation protection.
  • Key Issues: What quantities are used in radiation protection? Which quantities are suitable for area and individual monitoring?
  • Dosimetric Quantities & Units: Guidance by ICRU (International Commission on Radiation Units and Measurements).
  • Practical Application: Guidance by ICRP (International Commission on Radiological Protection). Details found in Chapter 16.
  • Basic Physical Dosimetry: Absorbed dose is the fundamental quantity.
  • Biological Effects: Different types of ionizing radiation have varying effectiveness in damaging human tissue. Quantities (equivalent dose) introduced to account for these biological effects.
  • Equivalent Dose (H): The basic quantity for radiation protection.
  • Defining Equivalent Dose: Two steps: Assess organ dose (DT). Use radiation-weighting factors (WR) to consider the biological effectiveness of different radiation types.

4.2.1 Dosimetric Quantities for Radiation Protection

  • Organ Dose (DT): Defined as mean absorbed dose (physical dose) in a specific body tissue/organ (T). Calculated using total energy imparted (ET) to the tissue/organ (T), divided by mass (mT) of that tissue/organ.
  • Radiation-Weighting Factors (WR): Values for specific radiation types illustrate biological effectiveness; Example: for X-rays, gamma rays and electrons WR = 1; protons =5, alpha particles = 20; neutrons depend on energy (5-20).
  • Operational Quantities: Indirectly used for practical measurements as equivalent dose is not directly measurable.

4.2.2/4.2.3/4.2.4 Operational Quantities

  • Operational Quantities for Area Monitoring: ICRU Sphere (30cm tissue-equivalent sphere). Used for (1) ambient dose equivalent(H*) ; and (2) directional dose equivalent(H').
  • Weakly and Strongly Penetrating Radiation: Different depths considered in ICRU sphere for different radiation types.
  • Ambient Dose Equivalent(H(d))*: Dose equivalent produced by an aligned and expanded field at a specific depth (d) in the ICRU sphere.
  • Directional Dose Equivalent(H'(d, Ω)): Dose equivalent produced by an expanded field at a specific depth (d) in the ICRU sphere at a specific direction.

4.2.5 Operational Quantities

  • Operational Quantity for Individual Monitoring: Personal dose equivalent (Hp(d)) is equivalent dose in soft tissue below a point on the body (at a specified depth, d).
  • Relevant Depth: 10 mm for strongly penetrating radiation, and 3mm (skin monitoring), 0.07mm (eye lens monitoring) for weakly penetrating radiation.

4.2.6 Summary

  • Operational Quantities for Area Monitoring: H*(d) & H'(d).
  • Operational Quantities for Individual Monitoring: Hp(d).

4.3 Area Survey Meters

  • Categories of Survey Meters: Gas-filled and Solid-state detectors.
  • Gas-Filled Detectors: Ionization chambers, Proportional counters, Geiger-Mueller counters.
  • Solid-State Detectors: Scintillator and Semiconductor detectors.
  • Properties of Gas-Filled Detectors: Noble gases used, the limit to the dose rate depends on the charge collection time.
  • Region Operation: Ionization, Proportional and Geiger-Mueller region are used depending on the voltage applied. Specific region can be used depending on the application.
  • Properties of Gas-Filled Detectors (Noble Gases Considerations):
  • High charge carrier mobility in these gases means a potentially higher dose rate monitoring capability.
  • Negative ions have lower mobility.
  • The noble gases don't easily become electronegative (forming negative ions from the absorption of electrons) which prevents additional charge generation.

4.3.1 Ionization Chambers

  • Mechanism: Ionization in chamber is directly proportional to the amount of charge for a given energy deposited by charged particle.
  • Discriminating Capability: LET (Linear Energy Transfer) Differences facilitate particle discrimination.
  • Build-up caps: Used to improve detection efficiency of high-energy photons. Should be removed for lower energy measurements.

4.3.2 Proportional Counters

  • Mechanism: Charged particle collisions, creating electron-ion pairs, amplify signals (103-104-fold).
  • Sensitivity: Greater than ionization chambers. Suitable for low-intensity radiation fields.

4.3.3 Neutron Area Survey Meters

  • Background: Neutron levels normally associated with photon backgrounds. Meters need to discriminate against photon background.
  • Mixed Fields: Neutron and photon fields have varied LET.
  • Discrimination: Gas-filled detectors (in proportional region) effective at discriminating.
  • Detecting Thermal Neutrons: Boron-10 nuclei react with thermal neutrons, producing alpha particles
  • Detecting Fast Neutrons: Fast neutrons are slowed by moderators (hydrogenous material) before detection.

4.3.4 GM Counters

  • Mechanism: In the GM region, the discharge spreads throughout the detector volume.
  • Pulse Height: Independent of primary ionization or energy of interacting particles; useful for low-level radiation fields.
  • Saturation: Not suitable for pulsed fields. Ionization chambers usually implemented instead.
  • Advantages: High sensitivity, suitable for measuring low radiation levels.

4.3.5 Scintillator Detectors

  • Mechanism: Contain atoms that emit light upon radiation absorption. Light converted to electrical signal by PMT.
  • Application: Mainly for gamma measurements—high atomic number phosphors. Plastic scintillators used for beta particles.

4.3.6 Semiconductor Detectors

  • Mechanism: Solid-state detectors with high sensitivity—about 104 times better than gas filled detectors.
  • Advantage: Allows for miniaturization of radiation monitoring instruments.

4.3.7 Common Features of Area Survey Meters

  • Various features: "Low battery" indication, auto-zeroing, auto-ranging, auto back-illumination. Data storage, and multiple operating modes(rate/integrate). Conventional and Dose equivalent display units.
  • Audio Indication: "Chirp" rate for radiation levels. Alarm facilities (re/non resettable) and adjustable levels.
  • Visual Indication: Flashing LEDs for radiation levels.
  • Calibration: Calibration to a reference instrument traceable to a national standards lab necessary.

4.3.8 Calibration of Survey Meters

  • Two Step Approach:
  • Step 1: Basic Radiation Measurement by using a reference instrument.
  • Step 2: Determination of equivalent dose by conversion coefficients (e.g., applying h(Kair)air = H*(10).

4.3.9 Properties (Sensitivity, Energy Dependency, Directional Dependency, Overload characteristics and Long term Stability)

  • Sensitivity: Defined as the inverse of the calibration factor (N), and is required to measure low level radiation. Scintillation-based systems more sensitive than GM. Ionization chamber sensitivity can be adjusted by decade resistances, larger volume detectors, and high-pressure gas.
  • Energy Dependence: Meters typically calibrated for variable qualities. Important to consider energy dependency in different operational quantity units.
  • Directional Dependence: Typically isotropic (constant response across different angles). Response within ±60° to ±80° required. Generally exhibits better performance for higher photon energies.
  • Overload Characteristics: Meters should be calibrated with dose rates 10 times the maximum scale range to ensure that a full scale reading occurs and doesn’t under-read the readings.
  • Long Term Stability: Requires periodic re-calibration every three years by a calibration laboratory .

4.4 Individual Monitoring

  • Definition: Measuring radiation doses received by individuals working with radiation. Used for workers in controlled /supervised areas, for verifying radiation control, for detecting changes in radiation levels in a workplace and to provide information in case of accidents.
  • Methods: TLD dosimetry, Film dosimetry, Radiophotoluminescence (RPL), Optically stimulated luminescence (OSL), albedo dosimeter, nuclear track emulsion
  • Self-reading pocket dosimeters: Electronic personal dosimeters, show instantaneous dose and accumulated dose in real time.

4.4.1 Film Badges:

  • Composition: Special photographic film in light-tight wrapper with filters.
  • Distinctive Pattern: Film shows distinctive pattern from filters. Different patterns can indicate different radiation types and energies.
  • Non-tissue Equivalence: Film is not tissue-equivalent. Requires filters for accurate measurements. One filter enough for high energy photons. Multiple filters for low energy.
  • Evaluation: Calibration films (exposed to known radiation doses of varying types) used to evaluate the radiation exposure. Optical density measured and compared.

4.4.2 TLD Badges:

  • Composition: Chips of luminescent materials encased in plastic with filters.
  • Common Phosphors: LiF:Mg,Ti; CaSO4:Dy; CaF2:Mn
  • Non-Tissue Equivalence: TLDs are not tissue equivalent if materials have high atomic number.
  • Fading: TLDs have less fading compared to film.
  • Specific Application: Convenient use in extremity dosimeters.

4.4.3 Radiophotoluminescent (RPL) Glass Dosimeters

  • Material: Silver activated phosphate glass.
  • Exposing to Radiation: Creates stable luminescence centres (Ag° and Ag++).
  • Readout: UV laser excitation; proportional light emission.
  • Measurement: Reader measures light intensity as indication for radiation exposure and converts to personal dose equivalent.
  • Advantages: Can reanalyze several times during readout, flat energy response, and no sensitivity to environmental temperature.

4.4.4 Optically stimulated luminescence (OSL) Dosimeters

  • Material: Thin aluminium oxide (Al2O3:C) layer used in dosimeters.
  • Analysis: Laser light stimulation results in luminescence proportional to radiation exposure
  • Ease of Use: Integrated, self-contained, and heat sealed.
  • Special filters: Provides qualitative info about exposure conditions.
  • Sensitivity: High sensitivity.
  • High precision: Used in low-radiation environments eg., 10μSv (Luxel system).

4.4.5 Direct Reading Personal Monitors

  • Categories: Self-reading pocket dosimeters and electronic personal dosimeters.
  • Mechanism of Self-reading Pocket Dosimeter: Capacitor-based ionization chamber for immediate dose measurement. Quartz moves proportionally to exposure.
  • Electronic Personal Dosimeter: Small GM counters or silicon detectors, display instantaneous and accumulated dose.
  • Calibration: Three steps: 1) Air Kerma measurement with Reference ionization chamber, 2)Theoretically determined coefficients (Hp(d)) = h(Kair)air slab, 3) Place dosimeter at a calibration point, determine the reading (M), and find calibration factor, NHp(d) = Hp(d)/M.

4.4.6 & 4.4.7 Calibration and Sensitivity

  • Calibration: Irradiation in standardized phantoms (slab, pillar, or rod) approximating human backscatter, using a standardized radiation source (e.g. Caesium-137)
  • Sensitivity: Varying sensitivities (0.1 mSv to 101 Sv) based on the dosimetry technique.
  • Energy Dependence: Film, and LiF-TLD dosimeters have energy dependencies; RPL dosimeters have a wide, flat energy response. EPDs generally have an energy compensation for a wide range.
  • Directional Dependence: Dosimeter should be iso-directional and have an angular response as the ICRU directional dose equivalent H'(10, Ω).
  • Uncertainty: ICRP guidelines exist for determining the measurement uncertainty which must be considered to compensate for inaccuracies in field measurements or in the case of unexpected high radiation intensities.

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

Related Documents

Description

Test your knowledge on various radiation monitoring instruments and dosimetric quantities. This quiz covers matching instruments with their descriptions, uses, and individual monitoring techniques. Challenge yourself to understand the characteristics and purpose of these essential tools in radiation safety.