RADEAGLE Technical Manual Quiz
48 Questions
0 Views

RADEAGLE Technical Manual Quiz

Created by
@ValiantSunstone

Questions and Answers

What is the default library of nuclides in the RADEAGLE?

  • Can be customized by the user
  • Includes all known nuclides
  • Is determined by the operating mode
  • Limited to a specific set of common nuclides (correct)
  • What is the purpose of the yellow region in the radiation field?

  • Indicates a potential threat due to high radiation levels
  • Highlights areas where the dose rate exceeds the warning threshold (correct)
  • Represents a safe zone where radiation levels are below the alarm threshold
  • Signifies that the radiation levels are above the background level but below the alarm threshold
  • What happens when the countdown timer reaches zero in EASY-ID MODE?

  • Alarms are triggered if radiation levels exceed the threshold
  • The instrument automatically starts a new measurement
  • The identified radiation source is displayed (correct)
  • The instrument switches to DETECT MODE
  • What is the default password to enter ADVANCED MODE?

    <p>LCRLC</p> Signup and view all the answers

    What does NORM stand for in the context of radioactive materials?

    <p>Naturally Occurring Radioactive Material</p> Signup and view all the answers

    What are the categories of radiation sources identified by EASY-ID MODE?

    <p>Alpha, beta, gamma, and neutron sources</p> Signup and view all the answers

    Which of the following is true about the RADEAGLE instrument?

    <p>The RADEAGLE is capable of detecting neutron radiation.</p> Signup and view all the answers

    What visual indication occurs when neutron radiation is detected?

    <p>Red LED flashes</p> Signup and view all the answers

    What should be preserved to establish claims for damage during delivery?

    <p>All of the above</p> Signup and view all the answers

    Which types of detectors are included in the RADEAGLE?

    <p>All of the above</p> Signup and view all the answers

    What kind of battery pack is used in the RADEAGLE?

    <p>Lithium-ion battery</p> Signup and view all the answers

    What does the EASY-ID MODE perform identification based on?

    <p>Radioactive decay signature</p> Signup and view all the answers

    Which of the following components is part of the RADEAGLE?

    <p>Computational subsystem</p> Signup and view all the answers

    What happens when you press the ABOUT button in the SETTINGS MENU?

    <p>It shows system version information</p> Signup and view all the answers

    What is the purpose of the initial stabilization process in the RADEAGLE?

    <p>To establish a baseline reading</p> Signup and view all the answers

    What are the colored LEDs on the RADEAGLE keyboard used for?

    <p>To provide visual feedback for key presses</p> Signup and view all the answers

    What is the operating time of the RADEAGLE under standard conditions?

    <p>Continuous operation</p> Signup and view all the answers

    What triggers different alarms when the dose rate exceeds thresholds?

    <p>All of the above</p> Signup and view all the answers

    What is the resolution specification for NaI:Tl at 661.6 keV?

    <p>1.5% FWHM</p> Signup and view all the answers

    What visual indication occurs when neutron radiation is detected?

    <p>Red LED flashes</p> Signup and view all the answers

    In DETECT MODE, what do green bars indicate?

    <p>Radiation levels close to background</p> Signup and view all the answers

    What does the yellow region represent in the radiation field?

    <p>Exceeds the warning threshold</p> Signup and view all the answers

    What must be done when neutron radiation is detected?

    <p>Immediately evacuate the area and contact emergency services.</p> Signup and view all the answers

    What button is used to manually trigger a new background level in DETECT MODE?

    <p>RESET button</p> Signup and view all the answers

    What should be done immediately if damage occurs during delivery of the RADEAGLE?

    <p>Inform ORTEC/innoRIID and preserve any relevant documentation.</p> Signup and view all the answers

    Which of the following statements is TRUE about the RADEAGLE's scintillation detector?

    <p>It can measure dose rates up to 150 Sv/h.</p> Signup and view all the answers

    What is the main purpose of the initial stabilization process in the RADEAGLE?

    <p>To ensure the instrument is properly initialized and ready for operation.</p> Signup and view all the answers

    What information is displayed when you press the ABOUT button in the SETTINGS MENU?

    <p>The current system version and build information.</p> Signup and view all the answers

    Which of the following statements is TRUE regarding the EASY-ID MODE?

    <p>It identifies radiation sources based on their energy spectrum.</p> Signup and view all the answers

    What type of battery pack is used in the RADEAGLE?

    <p>Lithium-ion battery pack.</p> Signup and view all the answers

    What can you do in the NUCLIDE SETTINGS screen?

    <p>Add or remove nuclides from the instrument's library.</p> Signup and view all the answers

    Which of the following components is NOT part of the RADEAGLE?

    <p>Mechanical arm.</p> Signup and view all the answers

    What is the main mechanism of measuring nuclear radiation in the RADEAGLE?

    <p>Detecting the interaction of radiation with specific materials</p> Signup and view all the answers

    What is the purpose of the initial stabilization process in the RADEAGLE?

    <p>To ensure the stability of the electronic components within the instrument</p> Signup and view all the answers

    What does the EASY-ID MODE perform identification based on?

    <p>The specific radioactive nuclide emitting the radiation</p> Signup and view all the answers

    What feature does RADEAGLE offer for detecting neutron counts?

    <p>A dedicated neutron detector that measures neutron flux directly</p> Signup and view all the answers

    What can you do in the NUCLIDE SETTINGS screen?

    <p>Modify the library of radioactive nuclides used for identification</p> Signup and view all the answers

    What is the default setting for the ID Time in EASY-ID MODE?

    <p>5 seconds</p> Signup and view all the answers

    What kind of assistance can ORTEC/innoRIID provide?

    <p>All of the above</p> Signup and view all the answers

    What are the colored LEDs on the RADEAGLE keyboard used for?

    <p>Providing visual feedback for different instrument functions</p> Signup and view all the answers

    Which nuclide has a half-life of 30 years?

    <p>137Cs</p> Signup and view all the answers

    What is the expected operational time of the RADEAGLE device under standard conditions?

    <p>&gt; 12 hours</p> Signup and view all the answers

    What visual indication is given when neutron radiation is detected?

    <p>Blue LED flashes</p> Signup and view all the answers

    Which statement about the RADEAGLE's corrective maintenance is accurate?

    <p>A Return Authorization Number is required</p> Signup and view all the answers

    What does the yellow region in the radiation field indicate?

    <p>Exceeds the warning threshold</p> Signup and view all the answers

    What type of alarms are triggered when the dose rate exceeds thresholds?

    <p>All of the above</p> Signup and view all the answers

    Which nuclide's half-life is closest to that of 241Am?

    <p>None of the above</p> Signup and view all the answers

    What happens in the RADEAGLE when neutron radiation is detected?

    <p>Visual indication is shown</p> Signup and view all the answers

    Study Notes

    RADEAGLE Technical Manual Quiz

    Damage and Claims

    • Notify the carrier and preserve packing materials, waybills, and bills of materials to establish claims for damage.
    • The carrier is not liable for damage in shipment if notified promptly.

    ORTEC/InnoRIID Assistance

    • ORTEC/InnoRIID provides assistance for RADEAGLE instruments.

    RADEAGLE Mechanism and Detectors

    • The main mechanism of measuring nuclear radiation in RADEAGLE is through its detectors.
    • The RADEAGLE includes Geiger-Mueller, scintillation, and neutron detectors.
    • The scintillation detector can measure dose rates up to 150 Sv/h.

    Initial Stabilization and Battery

    • The initial stabilization process is necessary for the RADEAGLE.
    • The RADEAGLE uses a Lithium-ion battery pack.

    Detector and LED Functions

    • The scintillation detector is the primary detector of the RADEAGLE instrument.
    • Colored LEDs on the RADEAGLE keyboard are used for indication purposes.

    Safety and Maintenance

    • It is not safe to unscrew the housing of the RADEAGLE for maintenance.

    EASY-ID Mode

    • EASY-ID MODE performs identification based on radiation source properties.
    • The default setting for the ID Time in EASY-ID MODE is not specified.
    • The nuclide library is accessible in the NUCLIDE SETTINGS screen.

    Neutron Detection and NORM

    • The RADEAGLE offers a feature for detecting neutron counts.
    • NORM stands for Naturally Occurring Radioactive Materials.

    Nuclides and Library

    • The nuclide 241Am is considered a threat material due to its radioactive properties.
    • The default library of nuclides includes certain nuclides.
    • The RADEAGLE can have an unknown nuclide.

    Operating Time and Resolution

    • The operating time of the RADEAGLE under standard conditions is greater than 8 hours.
    • The resolution specification for NaI:Tl at 661.6 keV is not specified.

    Corrective Maintenance and Radiation Field

    • Corrective maintenance for RADEAGLE instruments requires a Return Authorization Number.
    • The yellow region in the radiation field represents exceeding the warning threshold.

    Alarms and Neutron Sources

    • Different alarms are triggered when the dose rate exceeds thresholds, including visual, tactile, and auditory alarms.
    • Neutron sources are considered a threat and require action when detected.

    DETECT Mode and Background Level

    • The button used to manually trigger a new background level in DETECT MODE is not specified.
    • Green bars in DETECT MODE indicate radiation levels close to background.

    Radiation Detection and Indication

    • When neutron radiation is detected, the red LED flashes.
    • Categories of radiation sources identified by EASY-ID MODE include threat and non-threat materials.

    RADEAGLE Technical Manual Quiz

    Damage and Claims

    • Notify the carrier and preserve packing materials, waybills, and bills of materials to establish claims for damage.
    • The carrier is not liable for damage in shipment if notified promptly.

    ORTEC/InnoRIID Assistance

    • ORTEC/InnoRIID provides assistance for RADEAGLE instruments.

    RADEAGLE Mechanism and Detectors

    • The main mechanism of measuring nuclear radiation in RADEAGLE is through its detectors.
    • The RADEAGLE includes Geiger-Mueller, scintillation, and neutron detectors.
    • The scintillation detector can measure dose rates up to 150 Sv/h.

    Initial Stabilization and Battery

    • The initial stabilization process is necessary for the RADEAGLE.
    • The RADEAGLE uses a Lithium-ion battery pack.

    Detector and LED Functions

    • The scintillation detector is the primary detector of the RADEAGLE instrument.
    • Colored LEDs on the RADEAGLE keyboard are used for indication purposes.

    Safety and Maintenance

    • It is not safe to unscrew the housing of the RADEAGLE for maintenance.

    EASY-ID Mode

    • EASY-ID MODE performs identification based on radiation source properties.
    • The default setting for the ID Time in EASY-ID MODE is not specified.
    • The nuclide library is accessible in the NUCLIDE SETTINGS screen.

    Neutron Detection and NORM

    • The RADEAGLE offers a feature for detecting neutron counts.
    • NORM stands for Naturally Occurring Radioactive Materials.

    Nuclides and Library

    • The nuclide 241Am is considered a threat material due to its radioactive properties.
    • The default library of nuclides includes certain nuclides.
    • The RADEAGLE can have an unknown nuclide.

    Operating Time and Resolution

    • The operating time of the RADEAGLE under standard conditions is greater than 8 hours.
    • The resolution specification for NaI:Tl at 661.6 keV is not specified.

    Corrective Maintenance and Radiation Field

    • Corrective maintenance for RADEAGLE instruments requires a Return Authorization Number.
    • The yellow region in the radiation field represents exceeding the warning threshold.

    Alarms and Neutron Sources

    • Different alarms are triggered when the dose rate exceeds thresholds, including visual, tactile, and auditory alarms.
    • Neutron sources are considered a threat and require action when detected.

    DETECT Mode and Background Level

    • The button used to manually trigger a new background level in DETECT MODE is not specified.
    • Green bars in DETECT MODE indicate radiation levels close to background.

    Radiation Detection and Indication

    • When neutron radiation is detected, the red LED flashes.
    • Categories of radiation sources identified by EASY-ID MODE include threat and non-threat materials.

    RADEAGLE Technical Manual Quiz

    Damage and Claims

    • Notify the carrier and preserve packing materials, waybills, and bills of materials to establish claims for damage.
    • The carrier is not liable for damage in shipment if notified promptly.

    ORTEC/InnoRIID Assistance

    • ORTEC/InnoRIID provides assistance for RADEAGLE instruments.

    RADEAGLE Mechanism and Detectors

    • The main mechanism of measuring nuclear radiation in RADEAGLE is through its detectors.
    • The RADEAGLE includes Geiger-Mueller, scintillation, and neutron detectors.
    • The scintillation detector can measure dose rates up to 150 Sv/h.

    Initial Stabilization and Battery

    • The initial stabilization process is necessary for the RADEAGLE.
    • The RADEAGLE uses a Lithium-ion battery pack.

    Detector and LED Functions

    • The scintillation detector is the primary detector of the RADEAGLE instrument.
    • Colored LEDs on the RADEAGLE keyboard are used for indication purposes.

    Safety and Maintenance

    • It is not safe to unscrew the housing of the RADEAGLE for maintenance.

    EASY-ID Mode

    • EASY-ID MODE performs identification based on radiation source properties.
    • The default setting for the ID Time in EASY-ID MODE is not specified.
    • The nuclide library is accessible in the NUCLIDE SETTINGS screen.

    Neutron Detection and NORM

    • The RADEAGLE offers a feature for detecting neutron counts.
    • NORM stands for Naturally Occurring Radioactive Materials.

    Nuclides and Library

    • The nuclide 241Am is considered a threat material due to its radioactive properties.
    • The default library of nuclides includes certain nuclides.
    • The RADEAGLE can have an unknown nuclide.

    Operating Time and Resolution

    • The operating time of the RADEAGLE under standard conditions is greater than 8 hours.
    • The resolution specification for NaI:Tl at 661.6 keV is not specified.

    Corrective Maintenance and Radiation Field

    • Corrective maintenance for RADEAGLE instruments requires a Return Authorization Number.
    • The yellow region in the radiation field represents exceeding the warning threshold.

    Alarms and Neutron Sources

    • Different alarms are triggered when the dose rate exceeds thresholds, including visual, tactile, and auditory alarms.
    • Neutron sources are considered a threat and require action when detected.

    DETECT Mode and Background Level

    • The button used to manually trigger a new background level in DETECT MODE is not specified.
    • Green bars in DETECT MODE indicate radiation levels close to background.

    Radiation Detection and Indication

    • When neutron radiation is detected, the red LED flashes.
    • Categories of radiation sources identified by EASY-ID MODE include threat and non-threat materials.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    This quiz covers technical information about RADEAGLE instruments, including damage and claims, ORTEC/InnoRIID assistance, and RADEAGLE mechanism and detectors.

    More Quizzes Like This

    RADEAGLE Technical Manual Quiz
    78 questions
    Use Quizgecko on...
    Browser
    Browser