Primary Heat Transport Leakage Collection System

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the purpose of the Primary Heat Transport leakage collection system?

  • To collect drainages only from equipments for maintenance work.
  • To transfer the heavy water collected to the secondary cooling system.
  • To collect heavy water vapours (laden gas) vented during normal operation.
  • To collect heavy water internal leakages from various points of the PHT system. (correct)

What is one of the functions of the Primary Heat Transport leakage collection system?

  • Collect steam generated in the PHT system.
  • Remove impurities from the heavy water collected.
  • Transfer gases to the main reactor chamber for cooling.
  • Receive heavy water from a separate Heavy Water Addition Station. (correct)

Where does the Primary Heat Transport leakage collection system vent gases for heavy water recovery?

  • Fuelling machine vault air dryers. (correct)
  • Heavy water addition station reactor.
  • PHT purification IX and Filters.
  • Auxiliary building for chemical reaction.

When does the Primary Heat Transport leakage collection system transfer heavy water to the primary system?

<p>After purification through a separate circuit. (D)</p> Signup and view all the answers

What happens if heavy water is collected by the Primary Heat Transport leakage collection system?

<p>It goes through a clean-up system leading to plant upgrading. (A)</p> Signup and view all the answers

What is NOT a function of the Primary Heat Transport leakage collection system?

<p>Collecting steam released from the PHT system. (A)</p> Signup and view all the answers

What type of filters were replaced in the PHT purification system to enhance filtration efficiency?

<p>0.1 micron rating 'Positive Zeta potential' filters (C)</p> Signup and view all the answers

Which component is used in the PHT purification system for draining and venting of filter vessels & IX columns?

<p>Leakage collection tank (3371-TK-3) (C)</p> Signup and view all the answers

What is the maximum flow capacity that the PHT purification system is designed to handle?

<p>2000 lpm (B)</p> Signup and view all the answers

What is the purpose of the bleed flow in the purification system during normal operation?

<p>792 lpm at 40°C from the heat transport system (B)</p> Signup and view all the answers

Which flow is NOT part of the normal operation in the PHT purification system?

<p>2000 lpm maximum flow capacity (B)</p> Signup and view all the answers

What additional component is involved in the purification system after bleed cooler outlet?

<p>PHT leakage collection pump discharge line (B)</p> Signup and view all the answers