Podcast
Questions and Answers
What is the primary responsibility of the operator in manual refueling mode?
What is the primary responsibility of the operator in manual refueling mode?
- Automatically control the refueling valves
- Calculate fuel distribution and monitor quantities (correct)
- Physically open valves using mechanical overrides
- Monitor tank pressures during refueling
Which mode of pressure refueling is considered the standard for modern aircraft due to its safety and efficiency?
Which mode of pressure refueling is considered the standard for modern aircraft due to its safety and efficiency?
- Automatic mode (correct)
- Manual mode
- Override mode
- Emergency mode
What happens when the preselected block fuel is reached in automatic refueling mode?
What happens when the preselected block fuel is reached in automatic refueling mode?
- The refueling process automatically stops (correct)
- Fuel will overflow into the tanks
- The operator must reset the system
- Refueling continues until manually stopped
What is required to use override mode for refueling?
What is required to use override mode for refueling?
What is a notable advantage of automatic refueling mode compared to manual mode?
What is a notable advantage of automatic refueling mode compared to manual mode?
Flashcards are hidden until you start studying
Study Notes
Pressure Refueling Modes
- There are 3 modes of pressure refueling: manual, automatic, and override.
Manual Refueling
- Requires pre-calculation of fuel distribution
- Refueling valves are manually controlled through a control panel.
- Requires constant monitoring of fuel quantities in the tanks.
Automatic Refueling
- Uses a fuel quantity control computer to calculate fuel distribution based on block fuel preselection.
- Automatically controls the refueling valves for accurate fuel and distribution.
- Benefits: safe, reduces workload, stops refueling at preselected fuel.
- The standard mode on modern aircraft.
Override Refueling
- Used when electrical power to the refueling valves is unavailable.
- Refueling valves are opened by a mechanical override on the refueling valves, bypassing the electrical system.