What should be included in a Site Development Plan?

  • Soil exploration and load test results
  • Technical description, boundaries, and position of proposed non-architectural horizontal structures (correct)
  • Details of the building's foundation, floor framing, and roof plans
  • Only building orientation and proximity to existing utilities

What scale is required for Foundation Plans and Details?

  • At least 1:200
  • At least 1:500
  • At least 1:100 (correct)
  • At least 1:50

What type of building/structure does not require Structural Analysis and Design?

  • One storey building with a total floor area of 50 sq.meters
  • A building with a total floor area of 50.00 sq.meters or more
  • A building with five storeys
  • One storey and single detached building/structure with a total floor area of 20.00 sq.meters or less (correct)

When are boring and load tests required?

<p>For buildings or structures of three (3) storeys and higher (A)</p> Signup and view all the answers

Why are soil exploration, including boring and load tests, required?

<p>To identify potential geological/geotechnical hazards (D)</p> Signup and view all the answers

What is the purpose of a Structural Analysis and Design?

<p>To ensure the building's structural integrity (A)</p> Signup and view all the answers

What is the minimum number of elevations required in building plans?

<p>Four (4) (A)</p> Signup and view all the answers

What is the purpose of showing gridlines in building plans?

<p>To provide a reference for measurements and alignments (D)</p> Signup and view all the answers

What is typically included in a reflected ceiling plan?

<p>Design, location, and finishes of materials, lighting fixtures, and air conditioning exhausts (A)</p> Signup and view all the answers

What is the minimum scale required for a reflected ceiling plan?

<p>1:100 (B)</p> Signup and view all the answers

Who is authorized by law to review architectural plans and designs?

<p>A registered architect (RLA) (A)</p> Signup and view all the answers

What is the purpose of showing adjoining existing structures in elevations?

<p>To show the relationship between the new building and existing structures (B)</p> Signup and view all the answers

What is the minimum scale required for Plumbing Plans, Layouts, and Details?

<p>1:50 (C)</p> Signup and view all the answers

What type of drawing is required to show the systems of plumbing installations?

<p>Isometric drawings (C)</p> Signup and view all the answers

What is included in the electronic documents for telecommunications systems?

<p>All of the above (D)</p> Signup and view all the answers

What is the purpose of a legend in plumbing documents?

<p>To provide a list of abbreviations and symbols used in the plans (A)</p> Signup and view all the answers

What is the minimum scale required for Location Plans and Site Plans in plumbing installations?

<p>1:2000 (B)</p> Signup and view all the answers

What is the purpose of design analysis in plumbing documents?

<p>To analyze and evaluate the technical feasibility of the plumbing system (C)</p> Signup and view all the answers