Plumbing Code and Installation Quiz
18 Questions
2 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the minimum clearance required in front of a cleanout in piping 51 mm or less in size?

  • 102 mm (correct)
  • 504 mm
  • 50 mm
  • 305 mm

What is the term for two or more similar adjacent fixtures that discharge into a common horizontal soil or waste branch?

  • Side by side fixtures
  • Battery of fixtures (correct)
  • Back to back fixtures
  • Group of fixtures

What is the type of tee used to receive a threaded pipe or fittings?

  • Tapped tee
  • Branch tee
  • Closed tee
  • Threaded tee (correct)

What is the term for a water closet consisting of a continuous trough containing water?

<p>Continuous closet (A)</p> Signup and view all the answers

How far from any building or structure should a building sewer or other drainage piping not constructed of approved materials be installed?

<p>0.50 meters (B)</p> Signup and view all the answers

What is the code of sanitation of the Philippines with Implementing Rules and Regulations?

<p>PD 865 (A)</p> Signup and view all the answers

What occurs when a fixture vent pipe increases one pipe size its entire length?

<p>It will increase venting efficiency (A)</p> Signup and view all the answers

What is the typical standard diameter of a standpipe for buildings more than six stories tall?

<p>9&quot; (B)</p> Signup and view all the answers

What is the minimum pressure at which a pressure regulator should be installed?

<p>90 psi (D)</p> Signup and view all the answers

What is the purpose of a flushometer valve?

<p>To flush water closets and similar fixtures (A)</p> Signup and view all the answers

What is the lowest portion of the interior part of any pipe or conduit that is not vertical?

<p>Invert (C)</p> Signup and view all the answers

What is the copper content in brass fittings?

<p>90% (B)</p> Signup and view all the answers

What is the minimum finished interior area required for all shower compartments?

<p>0.70 square meters (B)</p> Signup and view all the answers

At what interval should copper tubing be supported for pipes 38 mm in diameter and smaller?

<p>1.5 meters (A)</p> Signup and view all the answers

What air pressure may be substituted for the water test in a plumbing system?

<p>433.5 Kpa (A)</p> Signup and view all the answers

What is the minimum height requirement for the critical level of a ballcock above the full opening of the overflow pipe?

<p>152 mm (D)</p> Signup and view all the answers

What type of pipe is not allowed to be used underground?

<p>Galvanized wrought iron pipe (B)</p> Signup and view all the answers

What is the purpose of an air gap in a plumbing system?

<p>To provide a physical separation between fixtures and the drainage system (C)</p> Signup and view all the answers