What is one of the activities plant personnel are responsible for during the shutdown?

  • Planning recreational activities for employees
  • Developing action plans for the cafeteria
  • Monitoring and controlling glass temperature during the shutdown (correct)
  • Managing the marketing campaign for the company
  • Where can the detailed process of proper preparation and installation of the capping orifice ring be found?

  • In Work Instruction EN-FHF-03-057 Spout Cap Off Process (correct)
  • In the company's annual report
  • In a general newsletter sent to employees
  • In a random social media post by the company
  • Which department is responsible for monitoring and controlling furnace glass level and bottom temperature during the shutdown?

  • Packaging department
  • Forehearth department
  • Furnace department (correct)
  • Forming department
  • What should be performed before shutting down the glass flow according to the text?

    <p>Performing activities for preparation and removal of parts of Refiner and Forehearth sub-systems</p> Signup and view all the answers

    Where do the guidelines for monitoring and controlling Refiner and Forehearth glass temperature during the shutdown come from?

    <p>MSDR EN-FHF-07-012 Glass Shutdown Operations</p> Signup and view all the answers

    What should be done with refractory stirring systems in the Colorant Alcove and paddle stirrers in the Forehearth equalizing section during production downtime?

    <p>They should be properly removed from the glass and kept hot inside the internal atmosphere.</p> Signup and view all the answers

    What is recommended for refractory needles during shutdown?

    <p>They should be lifted from the glass before capping off the spout.</p> Signup and view all the answers

    What is advised regarding the Thermocouples during the shutdown?

    <p>They should not have to be raised during the shutdown.</p> Signup and view all the answers

    When should electric boosting be turned off if the Forehearth is equipped with it?

    <p>Electric boosting should only be turned off during capping and uncapping steps.</p> Signup and view all the answers