Philippine Electrical Code (PEC) Quiz
12 Questions
10 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the minimum internal depth of a box?

  • 12 mm (correct)
  • 15 mm
  • 10 mm
  • 14 mm
  • Which of the following conductors has the highest resistance?

  • 8.0 mm²
  • 3.5 mm²
  • 5.5 mm²
  • 2.0 mm² (correct)
  • What is a device suspended from overhead by a flexible cord carrying current?

  • Rosette
  • Pendant (correct)
  • Fixture
  • Air terminal
  • What is the allowable ampacity of a THW insulated copper conductor with an area of 8.0 mm² exposed to 30°C?

    <p>45 A</p> Signup and view all the answers

    In what locations are splices in ground conductors to be attached?

    <p>To withstand a pull test of 900 Newton</p> Signup and view all the answers

    What is the classification of locations with combustible dust?

    <p>Class I</p> Signup and view all the answers

    What is the maximum electrical trade size of intermediate conduit?

    <p>150 mm</p> Signup and view all the answers

    What type of permit is needed before starting any installation work, alteration, repair or extension on any electrical system?

    <p>Electrical Permit</p> Signup and view all the answers

    What is the intended application of the Philippine Electrical Code (PEC) by government bodies exercising legal jurisdiction over electrical installation?

    <p>Mandatory</p> Signup and view all the answers

    How many groups are equipment for installation in hazardous locations divided into?

    <p>7</p> Signup and view all the answers

    What is the maximum rating of individual branch circuits using type FCC (flat conductor cable)?

    <p>20 A</p> Signup and view all the answers

    What type of conductor is applicable for underground service entrance conductors?

    <p>Type USE</p> Signup and view all the answers

    Study Notes

    Electrical Installation and Safety

    • Maximum electrical trade size of intermediate conduit is 200 mm.
    • Before starting any installation work, alteration, repair or extension on any electrical system, an Electrical Permit is needed.
    • The Philippine Electrical Code (PEC) is mandatory for applications by government bodies exercising legal jurisdiction over electrical installation.

    Hazardous Locations

    • Equipment for installation in hazardous locations must be tested and approved for use according to the classification of the hazards involved, and are divided into 3 groups.

    Electrical Conductors

    • Individual branch circuits using type FCC (flat conductor cable) shall have ratings not exceeding 20 A.
    • Type UF (underground feeder) cable is applicable for underground service entrance conductors.

    Installation Clearance

    • Bending space at each terminal shall not be less than 300 mm, provided the conductors do not enter or leave the enclosure through the wall opposite its terminals.
    • A clearance of not less than 13 mm shall be secured between bare current carrying metal parts and any metal surface of an auxiliary gutter.
    • No box shall have an internal depth of less than 12 mm.

    Electrical Devices

    • A Pendant is a device or equipment which is suspended from overhead either by means of a flexible cord carrying the current, or otherwise.

    Motor Circuits

    • In the schedule of loads for motor circuits, the type of motor, motor’s manufacturer, and motor as numbered or identified in the power layout are included.

    Electrical Conductors Ampacity

    • The allowable ampacity of THW insulated copper conductor with an area of 8.0 mm² and exposed to an ambient temperature of 30°C is 30 A.
    • For two conductors inside the conduit, the ampacity of the conductors shall be derated to 80%.

    Mounting Electrical Equipment

    • Electrical equipment may be best mounted on a concrete wall using an expansion bolt.

    Neutral Load

    • The neutral load of a range that has a demand load of 10.4 kW is 7.28 kW.

    Electrical Permit

    • If the project is expensive and requires more time for checking and for computations of fees, the issuance of the electrical permit need not be issued immediately, but the delay shall not be longer than 5 working days.

    Splices in Ground Conductors

    • Splices in ground conductors shall be as few as practicable and shall be attached so as to withstand a pull test of 880 Newton.

    Hazardous Locations Classification

    • Locations which are hazardous because of the presence of combustible dust are classified as Class II.

    Electrical Conductors Ampacity (Buried Underground)

    • A THW insulated copper conductor with a cross-sectional area of 3.5 mm² and buried underground has an ampacity of 15 A at an ambient temperature of 30°C.

    Lighting Protection System

    • All extended parts located within 1,600 mm of the lighting protection system shall be bonded thereto.

    Duty Classification

    • Operation at substantially constant load for an indefinitely long time is classified as Continuous duty.

    Transformer Location

    • Transformer exceeding 112.5 kVA shall not be located within 3 feet from combustible materials of the building.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Test your knowledge of the Philippine Electrical Code (PEC) with this quiz, covering topics such as electrical trade sizes, permits, and applications. Evaluate your understanding of electrical installation regulations and guidelines.

    More Like This

    Philippine Electrical Code Quiz
    10 questions
    Philippine Electrical Code (PEC) Quiz
    24 questions
    TLE-IA-EIM Quarter 3: Philippine Electrical Code OHS Standard Quiz
    17 questions
    Philippine Electrical Code Overview
    40 questions
    Use Quizgecko on...
    Browser
    Browser