Optimizing S-ICD Implant and Replacement
18 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the primary objective of optimizing S-ICD system location during implantation?

  • To ensure best patient outcome (correct)
  • To ensure a faster implantation process
  • To increase the complexity of the implantation process
  • To reduce the cost of the procedure
  • What is the primary consideration for S-ICD device placement in patients with high BMI?

  • Intermuscular placement
  • Submuscular placement
  • Latissimus Dorsi placement
  • Subcutaneous placement (correct)
  • Which of the following is a common challenge in S-ICD implantation?

  • Both high and low BMI patients (correct)
  • Neither high nor low BMI patients
  • Low BMI patients
  • High BMI patients
  • What is the purpose of the PRAETORIAN Score in S-ICD implantation?

    <p>To predict the risk of complications</p> Signup and view all the answers

    What is the recommended approach for suboptimal S-ICD placements?

    <p>To discuss tips and tricks with an expert physician</p> Signup and view all the answers

    What is the main benefit of using the S-ICD system?

    <p>Improved patient outcome</p> Signup and view all the answers

    What is the primary purpose of checking system impedance prior to defibrillation testing?

    <p>To determine the optimal location of the subcutaneous electrode and S-ICD pulse generator</p> Signup and view all the answers

    What does a system impedance value of > 400 ohms typically indicate?

    <p>The S-ICD electrode is not fully inserted into the header or is fractured</p> Signup and view all the answers

    What is the optimal range for high voltage shock impedance?

    <p>90 ohms</p> Signup and view all the answers

    What is the purpose of the Praetorian score?

    <p>To predict defibrillation success of the S-ICD</p> Signup and view all the answers

    What is one strategy for preparing and managing high BMI patients during S-ICD implantation?

    <p>Using a bariatric table if possible</p> Signup and view all the answers

    What is the potential consequence of system impedance values between 201-400 ohms?

    <p>Ineffective shock therapy</p> Signup and view all the answers

    What is a crucial consideration during pre-implant assessment?

    <p>Device size and patient activity levels</p> Signup and view all the answers

    What should be obtained from the device during replacement?

    <p>Data on previous therapy delivery (episodes)</p> Signup and view all the answers

    Why is the PRAETORIAN Score used during replacement?

    <p>To evaluate device and lead position (X-ray)</p> Signup and view all the answers

    What is a key consideration for optimal electrode placement during replacement?

    <p>Ensuring the electrode is not damaged</p> Signup and view all the answers

    Why is body habitus change a consideration for S-ICD system location?

    <p>It impacts sensing and conversion effectiveness</p> Signup and view all the answers

    What is a recommended technique for device placement?

    <p>Recommended Intermuscular technique</p> Signup and view all the answers

    More Like This

    Master ICD-10-PCS Root Operations
    10 questions
    Understanding ICD-9 & ICD-9-CM Codes
    18 questions
    ICD 10 Coding Flashcards
    27 questions

    ICD 10 Coding Flashcards

    GladLepidolite6058 avatar
    GladLepidolite6058
    Use Quizgecko on...
    Browser
    Browser