Podcast
Questions and Answers
What is the primary function of the air-operated isolation valves located inside the containment?
What is the primary function of the air-operated isolation valves located inside the containment?
What triggers the automatic closure of the containment isolation valves?
What triggers the automatic closure of the containment isolation valves?
What is the consequence of a loss-of-power or loss-of-air for the air-operated isolation valves?
What is the consequence of a loss-of-power or loss-of-air for the air-operated isolation valves?
What is the purpose of the steam generator blowdown flow instruments (FT-1171, 2, and 3)?
What is the purpose of the steam generator blowdown flow instruments (FT-1171, 2, and 3)?
Signup and view all the answers
What type of transmitters are used in the steam generator blowdown flow instruments (FT-1171, 2, and 3)?
What type of transmitters are used in the steam generator blowdown flow instruments (FT-1171, 2, and 3)?
Signup and view all the answers
What is the indicating range of the steam generator blowdown flow transmitters?
What is the indicating range of the steam generator blowdown flow transmitters?
Signup and view all the answers
What is the output signal of the steam generator blowdown flow transmitters?
What is the output signal of the steam generator blowdown flow transmitters?
Signup and view all the answers
What is the configuration of the air-operated isolation valves on unit 1?
What is the configuration of the air-operated isolation valves on unit 1?
Signup and view all the answers
What is the function of the pressure controller PC-1151?
What is the function of the pressure controller PC-1151?
Signup and view all the answers
What happens to the valve when there is a loss-of-power or loss-of-air?
What happens to the valve when there is a loss-of-power or loss-of-air?
Signup and view all the answers
What is the purpose of the inlet filter in the Steam Generator Blowdown system?
What is the purpose of the inlet filter in the Steam Generator Blowdown system?
Signup and view all the answers
What is the function of the Demineralizer Bypass Valve (AOV-7604)?
What is the function of the Demineralizer Bypass Valve (AOV-7604)?
Signup and view all the answers
How many bargraph LCD displays are on the FOXBORO 760 series controller?
How many bargraph LCD displays are on the FOXBORO 760 series controller?
Signup and view all the answers
What does the high pressure signal from PT-1153 do?
What does the high pressure signal from PT-1153 do?
Signup and view all the answers
What is the purpose of the deviation alarm on the SGBD panel?
What is the purpose of the deviation alarm on the SGBD panel?
Signup and view all the answers
What happens when the Demineralizer Isolation Valve (TCV-1150) is open?
What happens when the Demineralizer Isolation Valve (TCV-1150) is open?
Signup and view all the answers
How many demineralizers are there in the Steam Generator Blowdown system?
How many demineralizers are there in the Steam Generator Blowdown system?
Signup and view all the answers
What is the function of the SEL button on the keypad of the LCV-1003 controller?
What is the function of the SEL button on the keypad of the LCV-1003 controller?
Signup and view all the answers
What is the purpose of the steam generator shell drain pump?
What is the purpose of the steam generator shell drain pump?
Signup and view all the answers
What is the maximum temperature rise allowed for the cooling water in the blowdown heat exchanger?
What is the maximum temperature rise allowed for the cooling water in the blowdown heat exchanger?
Signup and view all the answers
What is the nominal blowdown flow rate of the system during low range operation?
What is the nominal blowdown flow rate of the system during low range operation?
Signup and view all the answers
What is the purpose of the temperature control valve TCV-3939?
What is the purpose of the temperature control valve TCV-3939?
Signup and view all the answers
What is the function of the Steam Generator Blowdown Heat Exchanger Outlet Flow Control Valve (FCV-1152)?
What is the function of the Steam Generator Blowdown Heat Exchanger Outlet Flow Control Valve (FCV-1152)?
Signup and view all the answers
What is the purpose of the Pressure Control Valve (PCV-1151)?
What is the purpose of the Pressure Control Valve (PCV-1151)?
Signup and view all the answers
What is the normal mode of operation for the blowdown heat exchanger?
What is the normal mode of operation for the blowdown heat exchanger?
Signup and view all the answers
What is the purpose of the steam generator blowdown flow control valves (HCV-1171, 2, and 3)?
What is the purpose of the steam generator blowdown flow control valves (HCV-1171, 2, and 3)?
Signup and view all the answers
What is the capacity of the steam generator shell drain pump?
What is the capacity of the steam generator shell drain pump?
Signup and view all the answers
What is the purpose of the temperature instrument TT-1150?
What is the purpose of the temperature instrument TT-1150?
Signup and view all the answers
What is the purpose of the Steam Generator Blowdown Outlet Filter?
What is the purpose of the Steam Generator Blowdown Outlet Filter?
Signup and view all the answers
What happens when the demineralizer train is bypassed and the blowdown is being processed?
What happens when the demineralizer train is bypassed and the blowdown is being processed?
Signup and view all the answers
What is the function of the Steam Generator Blowdown Surge Tank?
What is the function of the Steam Generator Blowdown Surge Tank?
Signup and view all the answers
What is the purpose of the level transmitter (LT-1158) in the Steam Generator Blowdown Surge Tank?
What is the purpose of the level transmitter (LT-1158) in the Steam Generator Blowdown Surge Tank?
Signup and view all the answers
What is the function of the Steam Generator Blowdown Discharge Pumps?
What is the function of the Steam Generator Blowdown Discharge Pumps?
Signup and view all the answers
What happens when the Steam Generator Blowdown Surge Tank level falls below 10%?
What happens when the Steam Generator Blowdown Surge Tank level falls below 10%?
Signup and view all the answers
What is the function of the Discharge Radiation Monitor (RE-23B)?
What is the function of the Discharge Radiation Monitor (RE-23B)?
Signup and view all the answers
What happens when the Discharge Radiation Monitor (RE-23B) detects a high activity signal?
What happens when the Discharge Radiation Monitor (RE-23B) detects a high activity signal?
Signup and view all the answers
What is the normal path for the blowdown fluid?
What is the normal path for the blowdown fluid?
Signup and view all the answers
What is the function of the Steam Generator Blowdown Surge Tank Level Control Valve (LCV-1158)?
What is the function of the Steam Generator Blowdown Surge Tank Level Control Valve (LCV-1158)?
Signup and view all the answers
What is the purpose of the R23B Bypass Switch?
What is the purpose of the R23B Bypass Switch?
Signup and view all the answers
What is the consequence of a loss-of-power or loss-of-air for the RCV023B valve?
What is the consequence of a loss-of-power or loss-of-air for the RCV023B valve?
Signup and view all the answers
What is the minimum flow rate required for the service water dilution flow when the SW Low Dilution Flow Trip is defeated?
What is the minimum flow rate required for the service water dilution flow when the SW Low Dilution Flow Trip is defeated?
Signup and view all the answers
What is the purpose of the FT-1160 instrument?
What is the purpose of the FT-1160 instrument?
Signup and view all the answers
What happens when the SGBD system is shut down and the sample system condensate return unit continues to pump water?
What happens when the SGBD system is shut down and the sample system condensate return unit continues to pump water?
Signup and view all the answers
What is the function of the Steam Generator Blowdown Discharge Pumps?
What is the function of the Steam Generator Blowdown Discharge Pumps?
Signup and view all the answers
What is the purpose of the three-position handswitch for the Steam Generator Blowdown Discharge Pumps?
What is the purpose of the three-position handswitch for the Steam Generator Blowdown Discharge Pumps?
Signup and view all the answers
What happens to the sample system condensate return unit when the SGBD system is tagged out?
What happens to the sample system condensate return unit when the SGBD system is tagged out?
Signup and view all the answers
Study Notes
High Energy Pipe Break Protection
- Two series isolation valves (7697A/B, 7698A/B, 7699A/B) are located inside the containment on each line from the steam generator to protect personnel and equipment outside the containment from a high energy pipe break of the blowdown system.
- These valves automatically close when high pressure (0.28-0.33 psig) is sensed in any room outside the containment where the blowdown piping is located.
- The valves will fail closed on a loss-of-power or loss-of-air.
Containment Isolation Valves (HV-7614A, B, and C)
- A containment isolation valve is located immediately outside the containment in each blowdown line.
- Each valve will automatically close upon an autostart of a motor-driven auxiliary feedwater (MDAFW) pump to aid in the recovery of the steam generator water level.
- These valves are controlled from the main control board (MCB) and fail closed on a loss-of-power or loss-of-air.
Steam Generator Blowdown Flow (FT-1171, 2, and 3)
- These instruments indicate the blowdown flow rate from each steam generator.
- Flow indication and low flow alarms are provided on the SGBD panel.
- The instruments, in conjunction with the associated flow controller (HIK-1171, 2, or 3), adjust the blowdown flow rate from each steam generator.
Steam Generator Blowdown Flow Control Valves (HCV-1171, 2, and 3)
- The air-operated blowdown flow control valves are modulated by their associated controllers (HIK-1171, 2, and 3) on the SGBD panel.
- The valves control the blowdown flow rate from each steam generator and fail closed on a loss-of-power or loss-of-air.
Steam Generator Shell Drain Pump
- The steam generator shell drain pump is used to lower the steam generator water level when it is cooled down < 200°F and depressurized.
- The pump has a 45 gpm capacity at 175' of head and receives power from motor control center MCC D.
Steam Generator Blowdown Heat Exchanger
- The heat exchanger sub-cools the blowdown fluid from steam generator exit conditions to 130°F, 10°F below the recommended maximum operating temperature for the demineralizer resin.
- The blowdown stream is cooled by service water to maintain a constant blowdown outlet temperature of approximately 130°F.
Steam Generator Blowdown Heat Exchanger Outlet Flow Control Valve (FCV-1152)
- This air-operated isolation valve automatically closes to protect the system or prevent the release of radioactive fluid to the environment.
- The valve will close on purification inlet filter high pressure, high heat exchanger outlet temperature, high activity, high surge tank level, and high flow.
Pressure Control Valve (PCV-1151)
- PCV-1151 maintains a constant pressure differential between the steam header pressure and the heat exchanger outlet.
- The backpressure on the hot blowdown fluid prevents excessive flashing upstream of the heat exchanger.
- The valve is controlled by pressure controller PC-1151 and fails closed on a loss-of-power or loss-of-air.
Steam Generator Blowdown Total Flow (FT-1152)
- FT-1152 indicates the total blowdown flow rate through the SGBD processing system.
- A high flow signal closes FCV-1152.
Steam Generator Blowdown Inlet Filter
- The inlet filter is designed to remove suspended particles in the blowdown stream to prevent plugging the resin beds.
- The filter is placed in service only during SGBD operation using the demineralizers.
- A bypass arrangement is provided for periods when demineralizer processing is not desired.
Demineralizer Bypass Valve (AOV-7604)
- When open, the air-operated demineralizer bypass valve will bypass the demineralizers.
- The valve is manually controlled from the SGBD panel and fails closed on a loss-of-power or loss-of-air.
Demineralizer Isolation Valve (TCV-1150)
- The air-operated demineralizer isolation control valve directs blowdown fluid to the demineralizers.
- The valve may only be open in the low range mode of operation and fails closed on a loss-of-power or loss-of-air.
Steam Generator Blowdown Demineralizers
- There are four demineralizers.
- The demineralizers are not presently used or maintained.
Steam Generator Blowdown Outlet Filter
- The outlet filter screens the demineralizer train effluent, eliminating the possibility of recycling or discharging resin particles.
Purification Outlet Radiation Monitor (RE-23A)
- The purification outlet radiation monitor determines the activity level of the fluid entering the surge tank.
- A high activity signal closes FCV-1152, which stops the blowdown.
Steam Generator Blowdown Surge Tank
- The surge tank provides a system surge capacity and ensures a sufficient net positive suction head (NPSH) to the discharge pumps.
- The surge tank has a capacity of 1420 gallons.
- A high level (90%) closes FCV-1152, while a low level signal (10%) shuts off the discharge pumps.
Steam Generator Blowdown Discharge Pumps
- Two canned motor pumps provide for recycle, discharge, and batch processing operations.
- Each pump has a design capacity of 75 gpm at a 350-ft head.
- The pumps are powered from 600V motor control center (MCC) C.
Steam Generator Blowdown Surge Tank Level Control Valve (LCV-1158)
- LCV-1158 is controlled from the surge tank level controller (LC-1158) located on the SGBD panel.
- The controller maintains 50% level in the tank by modulating LCV-1158.
Discharge Radiation Monitor (RE-23B)
- RE-23B monitors the activity level of the fluid leaving the SGBD.
- A high activity signal from this instrument closes RCV-23B, which prevents the discharge of high activity fluid to the environment.
Discharge Paths
- The blowdown fluid may either be discharged to the environment or to the main condenser.
- The normal path will be to the environment (river) via the service water dilution line.
- The blowdown will be recycled to the main condenser if the fluid does not meet the discharge limits or if a water conservation program is in effect.
Sample System Return
- The secondary sample system condensate return unit collects water from the steam system sample station and pumps the water collected to the SGBD system.
- When the SGBD system is shut down, the sample system condensate return unit continues to pump the water collected to the SGBD system.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
Test your knowledge of nuclear power plant operations, including isolation valves, containment systems, and steam generator flow instruments.