Flexible cords are permitted to be run through holes in walls, structural ceilings, suspended or dropped ceilings or floors.

False (B)

The total rating of a cord and plug connected room air conditioner must not exceed _____ of the rating of a branch circuit where lighting outlets, other appliances, or general use receptacles are also supplied.

50%

Except for storable pools, fixed or stationary equipment other than an underwater luminaire cord must not exceed ____ in length.

  • 3 ft (correct)
  • 5 ft
  • 4.5 ft
  • 2.5 ft

Receptacles located more than _____ above the floor are not required to be tamper resistant.

<p>5.5 ft (A)</p> Signup and view all the answers

The feeder circuit for a mobile or manufactured home must be rated at not less than ____ at 120/240V.

<p>100 A (C)</p> Signup and view all the answers

Ceiling grid which supports the wires may be permitted to support raceways.

<p>False (B)</p> Signup and view all the answers

______ circuit breakers or sets of fuses are acceptable as overcurrent devices to provide overload protection in one-family dwellings.

<p>2 to 6 (B)</p> Signup and view all the answers

At least _____ of free conductor, measured from the point in the box where it emerges from its raceway or cable sheath shall be left at each outlet, junction and switch point.

<p>6 in (A)</p> Signup and view all the answers

Splices and taps must be accessible and must not fill raceway to more than _____ of its cross-sectional area.

<p>75% (D)</p> Signup and view all the answers

A two-pole circuit breaker or fusible switch shall be considered as _____ overcurrent devices.

<p>Two (A)</p> Signup and view all the answers

_____ is the maximum approved electrical trade size for PVC conduit.

<p>6 in (B)</p> Signup and view all the answers

A portable generator is required to be grounded if the generator only supplies receptacles mounted on the generator.

<p>False (B)</p> Signup and view all the answers

The overhead service conductors above a roof with a slope of at least 4 in 12 in have a minimum clearance of ______.

<p>3 ft (C)</p> Signup and view all the answers

A switch or circuit breaker enclosure may be used as a raceway if the conductor fill does not exceed _____ :

<p>40% (A)</p> Signup and view all the answers

The ground detection sensing equipment must be connected as close as practicable to where the system receives its power supply.

<p>True (A)</p> Signup and view all the answers

The coupling means of the Electric Vehicle supply equipment must be stored or located not less than _____ above the floor level.

<p>18 in (A)</p> Signup and view all the answers

Receptacles must be mounted ____ or more above the deck surface of the pier.

<p>12 in (A)</p> Signup and view all the answers

GFCI protection is required for ____, 125V, general purpose receptacles located in dirt confinement areas for livestock.

<p>15 A and 20 A (C)</p> Signup and view all the answers

Cables listed for information technology equipment can be used to interconnect information technology equipment without the _____ cable length limit.

<p>15 ft (C)</p> Signup and view all the answers

Flashcards are hidden until you start studying

Study Notes

Flexible Cords and Equipment

  • Flexible cords cannot run through walls, ceilings, or floors.
  • The maximum rating for cord-connected air conditioners should not exceed 50% of the branch circuit rating when other outlets are supplied.

Equipment Specifications

  • Fixed or stationary equipment, excluding underwater luminaires, must have a cord length of no more than 3 ft.
  • Receptacles above 5.5 ft are not required to be tamper-resistant.

Mobile Home Requirements

  • Feeder circuits for mobile homes must have a minimum rating of 100 A at 120/240V.

Circuit Breakers and Fuses

  • Acceptable numbers for circuit breakers or fuses in single-family dwellings range from 2 to 6.
  • A two-pole circuit breaker or fusible switch counts as two overcurrent devices.

Conductor and Raceway Regulations

  • Leave a minimum of 6 in of free conductor at each outlet, junction, and switch point.
  • Splices and taps must be accessible and not fill raceways beyond 75% of their cross-sectional area.

Conduit Specifications

  • The maximum approved electrical trade size for PVC conduit is 6 in.

Portable Generators

  • A portable generator does not need to be grounded if it only supplies its own mounted receptacles.

Electrical Clearance and Safety

  • Overhead service conductors require a minimum clearance of 3 ft above roofs with a slope of at least 4 in on 12 in.
  • A switch or circuit breaker enclosure can function as a raceway if the conductor fill does not exceed 40%.

Ground Detection and Coupling

  • Ground detection equipment must connect close to the power supply source.
  • Coupling means for Electric Vehicle supply equipment must be located at least 18 in above the floor.

Receptacle Requirements

  • Receptacles should be mounted at least 12 in above the deck surface on piers.
  • GFCI protection is required for 15 A and 20 A general-purpose receptacles in animal confinement areas.

Cable Regulations

  • Information technology equipment cables can interconnect devices without exceeding a cable length limit of 15 ft.

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

More Like This

Introduction to NEC Flashcards
20 questions
National Electrical Code Flashcards
28 questions
Electrical Hazardous Locations Quiz
21 questions
Philippine Electrical Code (PEC) Overview
10 questions
Use Quizgecko on...
Browser
Browser