NAVMACS Troubleshooting and GUI Quiz
24 Questions
100 Views

NAVMACS Troubleshooting and GUI Quiz

Created by
@CalmingCornet

Questions and Answers

Which chapter of the Admin Manual (SAM) is used for troubleshooting?

Chapter 15

On the About NAVMACS screen, what is displayed? (Select all that apply)

  • Software Version (correct)
  • RHEL Version (correct)
  • Updates installed (correct)
  • None of the above
  • Which GUI would you use to update NAVMACS?

    Software Update

    What is the primary means of sending messages to shore?

    <p>CPU 3 C2OIX which uses SMTP</p> Signup and view all the answers

    ALT QUE is used in what scenario?

    <p>Message is RELAYED from secret to CUDIXS (RM backup)</p> Signup and view all the answers

    What is the purpose of MAD?

    <p>Visual and audio Alert Display</p> Signup and view all the answers

    What is the purpose of RADIANT Mercury?

    <p>Cross domain solution</p> Signup and view all the answers

    This GUI configures routing based on the context of a message. What is it called?

    <p>Profile (profiler)</p> Signup and view all the answers

    Types of NAVMACS message profiles include: (Select all that apply)

    <p>Shotgun</p> Signup and view all the answers

    After you complete updating software on NAVMACS, what is auto-generated?

    <p>SERVICE MESSAGE</p> Signup and view all the answers

    What apps does NAVMACS offer to test hardware? (Select all that apply)

    <p>Hardware Diags</p> Signup and view all the answers

    Radiant Mercury is located and uses what RAID?

    <p>CPU 1, Raid 0</p> Signup and view all the answers

    T/S is located and uses what RAID?

    <p>CPU 2, Raid 1</p> Signup and view all the answers

    Secret is located and uses what RAID?

    <p>CPU 3, Raid 1</p> Signup and view all the answers

    Where would you access/install PKI?

    <p>CPU 3 SMART CARD manager</p> Signup and view all the answers

    How often do we change passwords?

    <p>60 days</p> Signup and view all the answers

    How many switches does NAVMACS have and what are they?

    <p>2, Control LAN, T/S</p> Signup and view all the answers

    What app is used to control circuits?

    <p>Circuit control</p> Signup and view all the answers

    ____ are command NAVMACS guards for and is edited from command list.

    <p>ZKP</p> Signup and view all the answers

    How many serial ports per NAVMACS CPU?

    <p>8</p> Signup and view all the answers

    RM has __ serial ports.

    <p>0</p> Signup and view all the answers

    Radiant Mercury has how many HDs with a storage capacity of ____?

    <p>2, 240 gb</p> Signup and view all the answers

    What does SMN stand for?

    <p>System Message Number</p> Signup and view all the answers

    What is the purpose of Journal Data Summary?

    <p>Gives you detailed information about sent messages for audit trail purposes</p> Signup and view all the answers

    Study Notes

    • Chapter 15 of the Admin Manual (SAM) is designated for troubleshooting.
    • The About NAVMACS screen displays:
      • Software Version
      • RHEL Version
      • Installed updates
    • The GUI used to update NAVMACS software is called Software Update.
    • The primary means of sending messages to shore is CPU 3 C2OIX utilizing SMTP.
    • ALT QUE is employed for relaying messages from secret to CUDIXS as a backup (RM backup).
    • MAD serves as a visual and audio alert display for notifications.
    • RADIANT Mercury functions as a cross-domain solution.
    • The Profile GUI configures routing based on the context of messages.
    • Types of NAVMACS message profiles include:
      • RELAY
      • Exclusive
      • Inclusive
      • All messages
      • Shotgun
    • After updating NAVMACS software, a SERVICE MESSAGE is automatically generated.
    • NAVMACS offers applications for hardware testing:
      • Hardware Diags
      • Port Version Test
      • Network
    • Radiant Mercury is located in CPU 1 and utilizes RAID 0.
    • Troubleshooting (T/S) is located in CPU 2 and uses RAID 1.
    • The Secret module is located in CPU 3 and also utilizes RAID 1.
    • PKI access and installation can be done through the CPU 3 SMART CARD manager.
    • Passwords must be changed every 60 days.
    • NAVMACS consists of 2 switches: Control LAN and T/S.
    • The Circuit Control app is used to manage circuits.
    • ZKP refers to command NAVMACS guards and can be edited from a command list.
    • Each NAVMACS CPU has 8 serial ports.
    • Radiant Mercury has 0 serial ports.
    • Radiant Mercury utilizes 2 hard drives with a total storage capacity of 240 GB.
    • SMN stands for System Message Number, assigned to any message being released.
    • The Journal Data Summary provides detailed information about sent messages for audit trail purposes.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Test your knowledge about NAVMACS and its functionalities with our flashcards covering essential aspects like troubleshooting, software updates, and message sending. This quiz focuses on key components of the Admin Manual and the NAVMACS interface.

    Use Quizgecko on...
    Browser
    Browser