National Building Code Sec. 808 Quiz
18 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the minimum ceiling height required for habitable rooms with natural ventilation according to the Building Code?

  • 2.40 meters
  • 1.80 meters
  • 2.10 meters
  • 2.70 meters (correct)
  • For buildings more than one storey high, what is the minimum ceiling height required for the second floor according to the Building Code?

  • 2.40 meters (correct)
  • 2.70 meters
  • 1.80 meters
  • 2.10 meters
  • What is the minimum head room clearance required for succeeding floors in a multi-storey building according to the Building Code?

  • 2.40 meters
  • 1.80 meters
  • 2.10 meters (correct)
  • 2.70 meters
  • What is the clear ceiling height required for mezzanine floors as per the Building Code?

    <p>1.80 meters</p> Signup and view all the answers

    Where should electrical convenience outlets be installed in a residential house according to common standards?

    <p>30 centimeters above the floor line</p> Signup and view all the answers

    What is an important consideration when installing light switches in residential rooms?

    <p>Near the door for convenience</p> Signup and view all the answers

    What is the minimum size requirement for rooms intended for human habitations according to Sec. 806 of the National Building Code?

    <p>6 square meters with a least dimension of 2.00 meters</p> Signup and view all the answers

    According to the National Building Code, what is the window opening requirement for rooms without an artificial ventilation system?

    <p>Ten percent of the room floor area</p> Signup and view all the answers

    In room planning, what should be the primary consideration according to the text?

    <p>Accommodating furniture and appliances</p> Signup and view all the answers

    What is the minimum size requirement for a kitchen according to Sec. 806 of the National Building Code?

    <p>3.00 square meters with a least dimension of 1.50 meters</p> Signup and view all the answers

    Which factor should primarily influence the shape of planned elevations according to the text?

    <p>Strictly functional aspects</p> Signup and view all the answers

    According to Sec. 806 of the National Building Code, what is the minimum size requirement for a toilet and bath area?

    <p>1.20 square meters with a least dimension of 90 centimeters</p> Signup and view all the answers

    Why should the bedroom not be oriented facing the afternoon sun?

    <p>To prevent a warm atmosphere that requires artificial ventilation.</p> Signup and view all the answers

    What should be consulted first before deciding on the final site of a house or building?

    <p>Zoning ordinance</p> Signup and view all the answers

    Why is it important for the kitchen, laundry, and bathroom to be oriented west?

    <p>For better sunlight exposure that kills bacteria.</p> Signup and view all the answers

    Which of the following is a key aspect of height considerations for a room as per the National Building Code?

    <p>Ensuring a spacious floor area per person</p> Signup and view all the answers

    What is one of the consequences of constructing a residential house on an industrial or commercial zone according to the text?

    <p>Unhappiness for the family residing there</p> Signup and view all the answers

    Why does a moderate high ceiling allow fresh air circulation in a room?

    <p>To facilitate air movement within the room</p> Signup and view all the answers

    More Like This

    Use Quizgecko on...
    Browser
    Browser