MP in ACUVUE OASYS Production

SplendidArgon avatar
SplendidArgon
·
·
Download

Start Quiz

Study Flashcards

17 Questions

What MP applies to Tam 4 while producing ACUVUE OASYS?

MP-0142

What is the purpose of identifying Z8 Enclosure Door below carton hopper with Temporary Safety Warning Placard?

To indicate the presence of hazardous materials inside the enclosure

What is the significance of identifying Safety devices in the context of SHM?

To prevent accidents and ensure employee safety

Why are pallets lifted under Inlay plate and where are alignment pins located under Inlay Stripper Plate?

To prevent shingles when the robot arm pulls away

When is chamber and bottom blow used in precure?

To adjust the temperature around precure setpoint

What is the focus of Audits, Checks, and Inspections mentioned in EGOP-0017?

Identifying tasks related to Audits, Checks, and Inspections

What does MP-0142 refer to in the context of Tam 4 producing ACUVUE OASYS?

A specific manufacturing process for ACUVUE OASYS

What is the purpose of the parameter edit screen 4 for Heat Seal Compliant Head?

To modify the heat seal die function

What is the function of the 03IG-0501 Heat Seal Die stripper plate?

To remove excess material from the die

How does the machine identify arrays left behind in sterilizer tray in Zone 6?

By visual inspection

What is the purpose of saline buffer initialize function?

To reset the machine tracking system

What are the Nestal IMM Cycle Stop Procedures?

Press Manual Mode button and then Cycle Stop button

What is the benchmark distance for IR heads?

$35$ mm

What function do the hex pumps in tower 2 serve?

Maintaining mold temperature

How do you reset the Mitsubishi Robot in Zone 1?

Reset PLC0

What are the Reset Procedures for the Nestal IMM?

Press Manual Mode button to take machine out of Automatic mode. Press Reset button to reset fault. Correct fault. Restart per Cycle Start Procedures.

What are the Purging Procedures for the Nestal IMM?

Verify mold and barrel heat temperatures are within range, purge barrel if necessary.

Study Notes

Tam 4 Producing ACUVEE OASYS

  • MP applies when producing ACUVEE OASYS
  • MP-0142 refers to Tam 4 producing ACUVEE OASYS

Safety Features

  • Z8 Enclosure Door is identified with a Temporary Safety Warning Placard
  • Safety devices are significant in the context of SHM

Machine Functionality

  • Pallets are lifted under the Inlay plate, and alignment pins are located under the Inlay Stripper Plate
  • Chamber and bottom blow are used in precure
  • The parameter edit screen 4 is for Heat Seal Compliant Head
  • The 03IG-0501 Heat Seal Die stripper plate serves a specific function
  • The machine identifies arrays left behind in the sterilizer tray in Zone 6
  • Saline buffer initialize function serves a specific purpose

Audits and Inspections

  • Audits, Checks, and Inspections are focused on, as mentioned in EGOP-0017

Nestal IMM

  • Nestal IMM Cycle Stop Procedures are specific
  • Purging Procedures for the Nestal IMM exist
  • Reset Procedures for the Nestal IMM exist

Other

  • Hex pumps in Tower 2 serve a specific function
  • The benchmark distance for IR heads is specific
  • Mitsubishi Robot in Zone 1 can be reset following a specific procedure

Test your knowledge on the manufacturing process of ACUVUE OASYS by identifying the specific Manufacturing Practice (MP) that applies or doesn't apply to Tam 4 during production.