Module 8: Decontamination Point of Use Preparation and Transport
29 Questions
1 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What action facilitates effective cleaning of reusable medical devices?

  • Overloading mesh baskets
  • Placing devices on top of each other
  • Arranging devices in an orderly fashion in mesh trays (correct)
  • Leaving joints of devices closed

Why is it important to develop policies and procedures for handling, sorting, and disassembly of reusable medical devices?

  • To ensure effective cleaning in a timely manner (correct)
  • To damage the devices during cleaning
  • To overload mesh baskets
  • To minimize risk to the decontamination specialist

What should be done with jointed medical devices when placing them in a mesh basket for cleaning?

  • Open the joints in the mesh basket (correct)
  • Leave the joints in any position
  • Place devices without considering their joints
  • Close the joints

How should reusable medical device box locks and hinges be handled during the cleaning process?

<p>Open all box locks and hinges before cleaning (D)</p> Signup and view all the answers

What is the risk of placing reusable medical devices on top of one another during cleaning?

<p>Results in ineffective cleaning (B)</p> Signup and view all the answers

Why is it necessary to follow the manufacturer’s instructions for cleaning reusable medical devices?

<p>To prevent device damage and ensure proper cleaning (A)</p> Signup and view all the answers

What is one essential requirement for the immersion method of cleaning medical devices?

<p>Sink (C)</p> Signup and view all the answers

Why is temperature control necessary in the wash and rinse sinks during cleaning?

<p>To ensure effectiveness (usually &lt; 40C) (D)</p> Signup and view all the answers

Why is it recommended to always use brushes under water when cleaning medical devices?

<p>To avoid aerosols and splashing (C)</p> Signup and view all the answers

What is the best practice for drying manually washed devices that won't undergo further processing?

<p>Place them in a drying cabinet (B)</p> Signup and view all the answers

What is the preferred characteristic of brushes used for cleaning medical devices?

<p>Nondamaging with a range of diameters and lengths (A)</p> Signup and view all the answers

What information should the manufacturer provide regarding the brushes to be used for cleaning medical devices?

<p>Appropriate brush size (B)</p> Signup and view all the answers

What is the recommended number of sinks to be used for cleaning RMD?

<p>Three sinks (C)</p> Signup and view all the answers

What pH range is preferred for the mild detergent used in manual cleaning?

<p>8.0–11.5 (C)</p> Signup and view all the answers

Why should household soap never be used for cleaning RMD?

<p>It may cause damage to the devices (A)</p> Signup and view all the answers

What is the purpose of using an enzymatic detergent in cleaning devices with channels or complex parts?

<p>To facilitate the cleaning process (C)</p> Signup and view all the answers

How should lumened devices be flushed after cleaning with a jet-gun?

<p>Discharge under water to avoid splashing and aerosols (C)</p> Signup and view all the answers

Why is it important to ensure that the cleaning solution reaches all surfaces of devices being cleaned?

<p>To ensure proper sanitation (B)</p> Signup and view all the answers

What should be done with heavy retractors and other heavy medical devices during the cleaning process?

<p>Place them on the bottom or in a separate tray (C)</p> Signup and view all the answers

Why is it important to separate all sharp devices from general devices during the cleaning process?

<p>To facilitate easy assembly post-cleaning (D)</p> Signup and view all the answers

What is the purpose of connecting each lumen of medical devices to the appropriate flushing system?

<p>To prevent lumen blockages (A)</p> Signup and view all the answers

Why should receivers and gallipots not be placed over any other reusable medical devices during cleaning?

<p>To prevent shadowing and interference with the cleaning process (B)</p> Signup and view all the answers

When cleaning ratcheted devices, why is it necessary to open them up?

<p>To allow for better inspection of the joints and jaws (D)</p> Signup and view all the answers

Which step is recommended to secure small and light items during the cleaning process?

<p>Use a hold-down screen or other means (C)</p> Signup and view all the answers

What is the minimum level of processing required for non-critical devices that come into contact with intact skin?

<p>Cleaning and/or low/intermediate-level disinfection (D)</p> Signup and view all the answers

Which of the following is an example of a semi-critical device?

<p>Parkes retractor (A)</p> Signup and view all the answers

Which decontamination process is appropriate for devices that come into contact with sterile areas of the body, including blood contact?

<p>Sterilization (C)</p> Signup and view all the answers

What is the purpose of the decontamination process for reusable medical devices (RMDs)?

<p>To prevent infection by systematically decontaminating RMDs after each surgical procedure (C)</p> Signup and view all the answers

Which of the following statements is true regarding the validation of decontamination processes?

<p>All decontamination processes must be validated, and RMDs must be reprocessed to a level appropriate for their intended use (C)</p> Signup and view all the answers