ICP-MS is used to identify >90% of the elements in the periodic table with low detection limits, high degree of selectivity, good precision, and accuracy. The ICP Torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the ______.
ICP-MS is used to identify >90% of the elements in the periodic table with low detection limits, high degree of selectivity, good precision, and accuracy. The ICP Torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the ______.
sample
The high temperature in the ICP Torch leads to more complete atomization where the sample is broken down into its elements through hard ______.
The high temperature in the ICP Torch leads to more complete atomization where the sample is broken down into its elements through hard ______.
ionization
Laser ablation allows for solid sample introduction with minimal preparation as high intensity radiation rapidly vaporizes most ______.
Laser ablation allows for solid sample introduction with minimal preparation as high intensity radiation rapidly vaporizes most ______.
materials
The flow of argon carries the vaporized sample into the ICP torch where it can be used on samples to decompose or ______.
The flow of argon carries the vaporized sample into the ICP torch where it can be used on samples to decompose or ______.
Signup and view all the answers
Molecular Mass Spectrometry is the most widely applicable analytical tool and can be used for elemental composition of inorganic, organic, and biological ______.
Molecular Mass Spectrometry is the most widely applicable analytical tool and can be used for elemental composition of inorganic, organic, and biological ______.
Signup and view all the answers
The Ionization source in Molecular Mass Spectrometry generates a molecular ion in which the original molecule loses one electron but still has the same molecular ______.
The Ionization source in Molecular Mass Spectrometry generates a molecular ion in which the original molecule loses one electron but still has the same molecular ______.
Signup and view all the answers
Chap 20 Molecular Mass Spec provides the structure and composition of solid surfaces and the quantitative and qualitative composition of complex ______.
Chap 20 Molecular Mass Spec provides the structure and composition of solid surfaces and the quantitative and qualitative composition of complex ______.
Signup and view all the answers
The Spectrum in Molecular Mass Spec provides an isotopic ratio of atoms in the ______.
The Spectrum in Molecular Mass Spec provides an isotopic ratio of atoms in the ______.
Signup and view all the answers
ICP-MS has a mass range of 3-300, detection limit range at 0.1-10ppb, resolves ion differing by m/z of 1, and has a dynamic range of six orders of ______.
ICP-MS has a mass range of 3-300, detection limit range at 0.1-10ppb, resolves ion differing by m/z of 1, and has a dynamic range of six orders of ______.
Signup and view all the answers
Laser ablation beam can be directed to a specific location on the ______.
Laser ablation beam can be directed to a specific location on the ______.
Signup and view all the answers