LOWTEM Sterilizer Systems

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson
Download our mobile app to listen on the go
Get App

Questions and Answers

What is the primary focus of LOWTEM as a global enterprise?

  • Specializing in low temperature plasma sterilizer systems. (correct)
  • Producing pharmaceutical drugs.
  • Developing hospital infrastructure.
  • Manufacturing medical apparel.

In which year was LOWTEM Co., Ltd. founded?

  • 2005
  • 2010 (correct)
  • 2015
  • 2000

What is the main business activity of LOWTEM Co., Ltd.?

  • Developing low-temperature plasma sterilizers and consumables. (correct)
  • Manufacturing surgical instruments.
  • Producing hospital furniture.
  • Providing hospital management software.

Where is the headquarters and factory of LOWTEM Co., Ltd. located?

<p>Daegu, Korea (B)</p> Signup and view all the answers

Which of the following is a certified compatibility test that LOWTEM has?

<p>DaVinci endoscope (A)</p> Signup and view all the answers

Which of the following is a key element of the 'Rapid Warm-up & Dry System' in LOWTEM's product technology?

<p>Addressing moisture as a weakness in low-temperature plasma sterilizers. (A)</p> Signup and view all the answers

What is the function of the sterilizer tank's air vents?

<p>To remove the hydrogen peroxide gas inside the tank. (D)</p> Signup and view all the answers

What is the primary purpose of the safe interlock system in LOWTEM's sterilizers?

<p>To protect users from exposure during the sterilization process. (C)</p> Signup and view all the answers

What is the volume of the chamber in LOWTEM's sterilizer?

<p>130 Litres (A)</p> Signup and view all the answers

What is the main function of the RFID system in LOWTEM's sterilizers?

<p>To automatically control the expiration date and remained counts of the sterilant. (C)</p> Signup and view all the answers

What does the automatic PM alarm system provide?

<p>Automatic PM Alarms to prevent from irregular maintenance (A)</p> Signup and view all the answers

During a cycle with the LowTem sterilizer, which parameters can be monitored?

<p>Both temperature and pressure (C)</p> Signup and view all the answers

What sterilization process does the Steris V-PRO Max employ, differentiating it from some low-temperature plasma sterilizers?

<p>Vaporized Hydrogen Peroxide (VHP) sterilization (D)</p> Signup and view all the answers

Which feature distinguishes the door system of the LowTem Crystal 120M from the J&J Sterrad 100NX?

<p>Manual hinge door (B)</p> Signup and view all the answers

What type of sterilizing agent is used in the LowTem Crystal 120M?

<p>Hydrogen Peroxide (59%) (D)</p> Signup and view all the answers

Flashcards

What is LOWTEM?

A global enterprise specialized in low temperature plasma sterilizer systems, focusing on creating the safest environments for customers and patients.

Rapid Warm-up & Dry System

It overcomes the common weakness in moisture of Low Temperature Plasma Sterilizers, improving the efficiency of removing residual moisture after cleaning medical devices.

Simple Hydrogen Peroxide System

Sterilant tank can be simply installed and removed by one-touch system.

User-friendly door opening system

Prevents door plate deformation, improves durability with tension system.

Signup and view all the flashcards

Sterilant Tank Features

Safe, strong, and high-capacity tank type offers automatic control of expiration date and counts.

Signup and view all the flashcards

Automatic PM Alarm System

It provides automatic PM Alarms, useful for users and engineers.

Signup and view all the flashcards

Plug and Play

Short warming up time(10-15min) to start the cycle, and no need to wait to start a cycle

Signup and view all the flashcards

Self Test System

Convenient self diagnostic system that can be used for vacuum & leakage testing and parts tests.

Signup and view all the flashcards

Login Function

Functions to manage the access users.

Signup and view all the flashcards

Full Touch LCD Monitor

Full touch LCD, easy operation(simple icons and menu), user friendly, seven inches Monitor

Signup and view all the flashcards

Chamber Door

Safe automatic door interlock and door open system, automatic door locking system by one gentle push.

Signup and view all the flashcards

USB History Memory

Easy cycle history check and a user-friendly history download system

Signup and view all the flashcards

Monitoring the cycle and the printout

can monitor the temperature, pressure from the graph on the monitor

Signup and view all the flashcards

Study Notes

  • LOWTEM is a product presentation by Hazim Suhaimi from Project Sales (12-24).
  • More information can be found at www.its-asia.com.
  • The presentation includes an introduction to LowTem, product technology, specifications, features, product comparison, and a Q&A.

LowTem Introduction

  • LOWTEM is a global company specializing in sterilizer systems using low-temperature plasma.
  • LOWTEM focuses on creating the safest environments for customers and patients.
  • LOWTEM Co., Ltd. was founded in October 2010.
  • The main business is low-temperature plasma sterilizers and consumables.
  • The headquarters and factory are located in Daegu, Korea and the sales office is in Gyeonggi-do, Korea.
  • LOWTEM has the following certifications: KGMP, KFDA, ISO 13485, CE Mark (MDD 93/42/EEC), ISO 14937, MDA (MALAYSIA), GOST (RUSSIA), INVIMA (COLOMBIA) and also a certified compatibility test of DaVinci endoscope.
  • LOWTEM has 6 Korea patents
  • Patents include rapid warm-up & dry system, warm-up circulation and H2O2 concentration system, sterilant agent supply system, endoscope sterilizer or sterilizing methods, sterilizer door with sensor-opening structure, and a sterilizer that removes residual humidity using deep vacuum.

Product Technology: Rapid Warm-up & Dry System

  • Gets over common moisture weakness in low-temperature plasma sterilizers.
  • Improves efficiency in removing residual moisture from medical devices after cleaning.
  • Eliminates cold spots inside the chamber and loaded items.
  • Maintains uniform sterility.
  • Strengthens penetration power.
  • Is considered to be a world's first technology.
  • There's a notable temperature difference (~20°C) with fan and heater versus without fan and heater.

Product Technology: Hydrogen Peroxide Supply System

  • Sterilant tanks are easily installed and removed.
  • It has an automatic closing system.
  • The system's simple design accurately supplies hydrogen peroxide, and reduces production costs.

Product Technology: Sterilization Supply System

  • The hydrogen peroxide tank that is safe, easy and convenient to handle, store, ship.
  • Sterilant is highly concentrated hydrogen peroxide.
  • The sterilant tank is the safest way to package and deliver.
  • The tank has special air vents to remove the hydrogen peroxide gas to prevent explosions.
  • The tank can be safely handled, stored, and shipped with the four special air vents.

Product Technology: Door Opening System

  • A tension system prevents door plate deformation or distortion from repeated vacuum use.
  • Durability is improved.
  • Unlike other plasma sterilizers, there is a user friendly sensor opening door, chambers are easily opened and closed.
  • During sterilization, an automated interlock system protects users from exposure to sterilant.

Specifications

  • Sterilizing agent is Hydrogen Peroxide and it does 20 cycles a tank.
  • Cycle times include Quick (30±5min), Standard (40±5min), and Special (50±5min).
  • Dimensions measure 680(W) x 1575(H) x 940(D) mm and weighs 300kg.
  • Chamber is Rectangular and 420(W) x 400(H) x 775(D) mm.
  • Total volume is 130 Litres.
  • Printer is Built-in Thermal type and uses (60Ø Roll Paper).
  • The controlling system is Microprocessor + Embedded Computer
  • Main equipment includes Full Touch LCD, Sterilizing Agent, Chamber Door, Chamber, and Thermal Printer.

Product Features

  • Sterilant: Safe, strong and high-capacity tank; economical and environmentally friendly and it uses an RFID system to automatically control expiration dates and remaining counts.
  • Full touch LCD monitor: Easy operation with simple icons/menu; user-friendly seven-inch full-touch monitor.
  • Chamber Door: Safe automatic door interlock/open system; automatic locking via gentle push; automatic door open by sensor.
  • USB History Memory: Easy cycle history check; user-friendly download system.
  • Automatic PM Alarm System: Provides PM alarms to prevent irregular maintenance; Useful for users and engineers.
  • Plug and Play: Short 10-15 min warming; no need to wait to start a cycle.
  • Monitoring Cycle and Printout: Monitors temperature/pressure from graphs and prints results w/cycle graphs; can reprint sterilization results.
  • Spacious Chamber Size: Maximizes chamber space; Crystal 120M/120D has 130 liters.
  • Self Test System: Convenient self-diagnostic system; vacuum/leakage testing; parts test.
  • Login Function: Manages access users.

Product Comparison

  • The LowTem Crystal 120M has an innovative application of the world's first patented rapid warmup and dry system. Rivals are sensitive to residual humidity.
  • The LowTem Crystal 120M, Sterrad 100NX, V-PRO Max, and PL 130 all uses Hydrogen Peroxide (59%) as an agent
  • The LowTem Crystal 120M can perform 20 cycles
  • The Sterrad 100NX can perform 5 cycles
  • The V-PRO Max can perform 15 cycles
  • The Steelco PL 130 can perform 1 cycle
  • The LowTem Crystal 120M door has a Manual Hinge
  • The Sterrad 100NX door is an automatic sliding
  • The V-PRO Max door has a Manual Hinge
  • The Steelco PL 130 door is an automatic sliding
  • LowTem Crystal 120M dimensions are 600W x 1600H x 930D
  • Sterrad 100NX dimensions are 775W x 1791H x 1016D
  • V-PRO Max dimensions are 838W x 1908H x 973D
  • Steelco PL 130 dimensions are 770W x 1685H x 1040D
  • LowTem Crystal 120D, J&J Sterrad 100NX, Steris V-PRO Max, and Steelco PL 130 uses different power supplies, measured to be 13A SSO, 36A Isolator, 36A Isolator, and 36A Isolator respectively.

Installation Base

  • Hospital Tengku Ampuan Rahimah Klang has a C120M, Qty 1, Year 2019
  • Hospital Sungai Buloh has a C50, Qty 1, Year 2019
  • Hospital Pulau Pinang has a C120M, Qty 1, Year 2019
  • Hospital Tanah Merah has a C120M, Qty 1, Year 2020
  • Hospital Miri has a C120M, Qty 2, Year 2023
  • Hospital Seri Iskandar has a C120M, Qty 1, Year 2024
  • Hospital Bachok has a C50, Qty 1, Year 2024
  • Hospital Pasir Gudang has a C120M, Qty 3, Year 2024
  • Hospital Lawas has a C120M, Qty 2, Year 2024
  • Hospital Kapar has a C50, Qty 5, Year 2025

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

Related Documents

More Like This

Microbial Storage at Low Temperature Quiz
18 questions
Low Temperature Sterilization Quiz
24 questions
LOWTEM Product Presentation Overview
46 questions
Use Quizgecko on...
Browser
Browser