Load Combinations in Structural Design
24 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What do dead loads include in the context of construction design?

  • The weight of temporary structures
  • The load of people and furnishings inside the building
  • The weight of all materials of permanent construction (correct)
  • The dynamic effects of wind and earthquake forces
  • In the absence of definite information, which option is acceptable for determining dead loads?

  • Applying only theoretical weights based on design
  • Estimating weights based on visual inspections
  • Using average values across similar structures
  • Using the minimum values in specified tables (correct)
  • What is the uniformly distributed dead load that must be designed for floors in buildings with changeable partition locations?

  • 2.0 kPa of floor area
  • 1.5 kPa of floor area
  • 0.5 kPa of floor area
  • 1.0 kPa of floor area (correct)
  • Which of the following best defines dead loads for a structure?

    <p>Static loads that do not change over time</p> Signup and view all the answers

    Which of the following components is NOT considered part of dead loads?

    <p>Occupant furniture</p> Signup and view all the answers

    What characteristic of dead loads is emphasized in structural design?

    <p>They consist of permanent materials within the structure.</p> Signup and view all the answers

    When designing for dead loads, what additional consideration is required specifically for office buildings?

    <p>Support additional loads due to movable partitions</p> Signup and view all the answers

    What items are typically included in the calculation of dead loads?

    <p>Components like stairways and ceilings</p> Signup and view all the answers

    What does the symbol D represent in load calculations?

    <p>Dead load</p> Signup and view all the answers

    In which load combination is the dead load D multiplied by a factor of 0.9?

    <p>0.9<em>D</em> + 1.6<em>W</em> + 1.6<em>H</em></p> Signup and view all the answers

    Which of the following best describes a dead load in structural design?

    <p>The weight of the structure and fixed elements</p> Signup and view all the answers

    Which load includes factors for temperature change, shrinkage, and movement?

    <p>Self-straining force</p> Signup and view all the answers

    What is the factor for live load in places of public assembly as denoted by f1?

    <p>1.0</p> Signup and view all the answers

    In the combination 1.2D + 1.6W + f1L* + 0.5(Lr or R), which load is included as a variable?

    <p>Roof live load</p> Signup and view all the answers

    What is the primary consideration for a retaining wall in structural engineering?

    <p>Resisting lateral soil displacement</p> Signup and view all the answers

    Which load is referred to when discussing the load due to lateral pressure of soil and water?

    <p>Dead load</p> Signup and view all the answers

    What characterizes live loads in a building structure?

    <p>They are produced by the use and occupancy of the building.</p> Signup and view all the answers

    Which of the following accurately describes dead loads?

    <p>They include forces from the weight of building materials.</p> Signup and view all the answers

    What is an example of a variable load on a structure?

    <p>Occupancy loads due to furniture and equipment.</p> Signup and view all the answers

    Which of the following statements about dead loads is false?

    <p>They occasionally vary in magnitude.</p> Signup and view all the answers

    In the context of structural loads, what is the primary distinction between dead loads and live loads?

    <p>Live loads vary over time, whereas dead loads are constant.</p> Signup and view all the answers

    What types of loads are excluded from the definition of live loads?

    <p>Both A and B.</p> Signup and view all the answers

    Which of the following is NOT considered a permanent load?

    <p>The weight of occupants and furnishings.</p> Signup and view all the answers

    What is the consequence of neglecting dead loads in structural design?

    <p>Potential structural failure or instability.</p> Signup and view all the answers

    Study Notes

    Load Combinations Using Allowable Stress

    • Structures must resist critical effects from specified load combinations defined in Section 203.4.
    • Basic load combinations include:
      • D (dead load) + F (fluid load)
      • D + H (hydrostatic load) + F + L (live load) + T (temperature effects)
      • Other variations include live load or rain load combinations.

    Special Seismic Load Combinations

    • Seismic design incorporates specific load combinations as required by Sections 208 or Chapters 3-7.
    • Notable combinations:
      • 1.2D + f1L* + 1.0Em (earthquake load)
      • 0.9D + 1.0Em
    • f1 varies based on occupancy and live load conditions.

    Dead Loads

    • Consist of the weight of construction materials including walls, floors, and equipment.
    • Actual weights should be used; minimum values are permitted in the absence of accurate data.
    • Partition loads in flexible spaces must accommodate an additional dead load of 1.0 kPa.

    Live Loads

    • Defined as loads from building use and occupancy, excluding dead loads, environmental loads, or construction loads.
    • Permanent loads have minor variation over time, while all other loads are classified as variable.

    Load and Resistance Factor Design (LRFD)

    • Proportions structural elements ensuring no limit state is reached with load combinations.
    • Employed mainly in the design of steel structures.

    Strength Design

    • A method used primarily for concrete structures to ensure computed forces from factored loads do not exceed design strength.

    Structural Wall Classifications

    • Bearing Wall: Supports significant vertical loads (metal/wood stud walls over 1.45 kN/m, masonry/concrete walls over 2.90 kN/m).
    • Nonbearing Wall: Does not support vertical loads.
    • Exterior Wall: Defines building's outer boundary; has a slope of 60 degrees or greater.
    • Parapet Wall: Extends above the roof line.
    • Retaining Wall: Prevents lateral soil displacement.

    Combinations of Loads

    • Structures must resist combinations specified in Sections 203.3 or 203.4, with special seismic requirements as outlined in Section 208.

    Symbols and Notations

    • Common load symbols defined:
      • D = Dead load
      • E = Earthquake load
      • F = Fluid pressure load
      • H = Soil and water lateral pressure load
      • L = Live load
      • P = Ponding load
      • R = Rain load
      • T = Temperature-related forces
      • W = Wind load

    Strength Design Load Combinations

    • Factored load combinations include:
      • 1.4(D)(F)
      • 1.2(D+F+T) + 1.6(L+H) + 0.5(Lr or R)
      • Specific ratios for earthquake, wind, and other variables.

    Other Loads Consideration

    • For ponding load (P), factor into design as 1.2P when necessary.