Nebulizer Article

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson
Download our mobile app to listen on the go
Get App

Questions and Answers

Which variables influence the effectiveness of aerosol drug delivery during mechanical ventilation?

  • Patient's age and gender
  • Nebulizer type and position on the ventilator circuit (correct)
  • Ventilator brand and model
  • Humidity level in the patient's room

What was nebulized in the study to determine the influence of nebulizer position and bias flow?

  • Saline solution
  • Albuterol sulfate (2.5 mg) (correct)
  • Corticosteroids
  • Sterile water

Where was the jet nebulizer placed in the second nebulizer position?

  • Positioned at an inlet to the humidifier
  • Before the heated humidifier with 15 cm of large-bore tubing (correct)
  • 15 cm from the Y-piece adapter
  • Directly attached to the Y-piece

What was used as simulated models in the study?

<p>Simulated pediatric and adult lung models (B)</p> Signup and view all the answers

Which factors had not been established for different age populations according to the article?

<p>Impact of nebulizer type, position, and bias flow on aerosol drug delivery (B)</p> Signup and view all the answers

What is the main objective of this study?

<p>To evaluate the influence of nebulizer position and bias flow on aerosol drug delivery (D)</p> Signup and view all the answers

What is the effect of nebulizer placement on drug delivery according to the study?

<p>Nebulizer placement prior to the humidifier increased drug delivery with both the jet nebulizer and the vibrating-mesh nebulizer, with a greater increase with the jet nebulizer. (D)</p> Signup and view all the answers

Which type of nebulizer provided higher efficiency when placed proximal to the ventilator during simulated adult mechanical ventilation, according to the study?

<p>Jet nebulizers (C)</p> Signup and view all the answers

What factor greatly influences aerosol drug delivery in mechanically ventilated adults, as reported in the study?

<p>Peak inspiratory flow (A)</p> Signup and view all the answers

What impact did higher bias flow have on drug delivery during simulated mechanical ventilation in both lung models?

<p>Higher bias flow reduced drug delivery. (A)</p> Signup and view all the answers

What was the inner-diameter of the endotracheal tubes used for the adult and pediatric lung models, respectively?

<p>8-mm for adult and 5-mm for pediatric lung models (A)</p> Signup and view all the answers

What method was used to analyze albuterol sulfate in the study?

<p>Spectrophotometry (D)</p> Signup and view all the answers

What is a key factor that influences aerosol drug deposition in intubated and mechanically ventilated patients, according to the study?

<p>Physical properties of the drug (A)</p> Signup and view all the answers

Which factor differentiates aerosol delivery efficiency according to previous studies mentioned in the text?

<p>Residual drug volume (D)</p> Signup and view all the answers

What did Hughes and Saez find regarding nebulizer placement influencing aerosol drug delivery during mechanical ventilation?

<p>Moving the nebulizer back to the manifold position doubled the aerosol drug delivery during mechanical ventilation, compared to nebulizer placement at the Y-piece. (C)</p> Signup and view all the answers

What did recent studies compare regarding aerosol drug delivery efficiency during simulated adult mechanical ventilation?

<p>They compared efficiency across different types of nebulizers and various positions. (D)</p> Signup and view all the answers

In the study, which type of nebulizer consistently delivered more drug than the other?

<p>Vibrating-mesh nebulizer (A)</p> Signup and view all the answers

What was the impact of bias flow on aerosol delivery according to the findings of the study?

<p>Decrease in drug delivery with increasing bias flow (C)</p> Signup and view all the answers

What was the difference in aerosol delivery between position 1 and position 2 with the pediatric model using a jet nebulizer?

<p>Similar delivery at both positions (A)</p> Signup and view all the answers

Why did the vibrating-mesh nebulizer deliver less drug when positioned at the ventilator in a previous study?

<p>Greater internal volume of the circuit and humidifier chamber (C)</p> Signup and view all the answers

What was the effect of bias flow on aerosol delivery with the vibrating-mesh nebulizer in the adult circuit?

<p>Increased drug delivery with increasing bias flow (C)</p> Signup and view all the answers

What was the impact of bias flow on aerosol delivery with the jet nebulizer in the adult circuit?

<p>Decrease in drug delivery with increasing bias flow (C)</p> Signup and view all the answers

What was the difference in aerosol delivery between position 2 and position 1 with the adult model using a vibrating-mesh nebulizer?

<p>Increased delivery at position 2 (B)</p> Signup and view all the answers

What was the impact of bias flow on aerosol delivery with the jet nebulizer in the pediatric circuit?

<p>No impact on drug delivery (B)</p> Signup and view all the answers

What was the difference in aerosol delivery between the adult and pediatric models at position 2 using a jet nebulizer?

<p>Similar delivery in both models (D)</p> Signup and view all the answers

What was found to be consistent across both adult and pediatric models according to the study findings?

<p>Similar aerosol delivery with both nebulizer types (C)</p> Signup and view all the answers

What was speculated as a possible reason for reduced drug delivery when a vibrating-mesh nebulizer was positioned at the ventilator?

<p>Lack of aerosol reservoir effect (A)</p> Signup and view all the answers

What is one of the findings of greatest clinical relevance according to the study?

<p>Minor impact on efficacy or patient safety due to bias flow (C)</p> Signup and view all the answers

What can reduce aerosol delivery by up to 50% compared to ventilation under ambient conditions with anhydrous gas mixtures?

<p>Heating and humidifying the circuit gas (B)</p> Signup and view all the answers

What is the purpose of continuous bias flow through the ventilator circuit?

<p>To reduce patient work of breathing (C)</p> Signup and view all the answers

Which factor reduces aerosol delivery efficiency in infants and small children compared to adults?

<p>Differences in anatomical proportion (C)</p> Signup and view all the answers

What did the study aim to determine the influence of during simulated mechanical ventilation of pediatric and adult patients?

<p>Bias flow, nebulizer type, and position on aerosol drug delivery (C)</p> Signup and view all the answers

What is the purpose of maintaining the natural curve of the endotracheal tube (ETT) during ventilation?

<p>To prevent condensate or liquid medication from reaching the filter media (B)</p> Signup and view all the answers

Which nebulizer uses pressurized gas to form a jet passing over a capillary tube that draws liquid formulation into the jet stream to produce aerosol?

<p>Misty Finity (Cardinal Health, Dublin, Ohio) (C)</p> Signup and view all the answers

Which device uses electricity to vibrate an aperture plate at 128 kHz to produce aerosol?

<p>AeroNeb Solo (Aerogen, Mountain View, California) (D)</p> Signup and view all the answers

What was the compliance of the test lung set to simulate a mechanically ventilated adult or small pediatric patient?

<p>$0.1 L/cm H2O$ (B)</p> Signup and view all the answers

What is the main advantage of the vibrating-mesh nebulizer over the jet nebulizer?

<p>Higher drug delivery efficiency (C)</p> Signup and view all the answers

In the study, how did the vibrating-mesh nebulizer compare to the jet nebulizer in terms of aerosol delivery?

<p>Vibrating-mesh nebulizer delivered 2–4 times more aerosol than the jet nebulizer (C)</p> Signup and view all the answers

At which position in the ventilator circuit was the vibrating-mesh nebulizer more efficient?

<p>Position 2 for both adult and pediatric models (C)</p> Signup and view all the answers

How did the bias flow affect aerosol drug delivery with the jet nebulizer?

<p>Higher bias flow decreased aerosol drug delivery (C)</p> Signup and view all the answers

What was used to determine the albuterol concentration in the experiments?

<p>Spectrophotometry (C)</p> Signup and view all the answers

What was the residual drug volume for the vibrating-mesh nebulizer?

<p>0.1–0.3 mL (B)</p> Signup and view all the answers

How many times was each experiment run in the study?

<p>3 (A)</p> Signup and view all the answers

What was used to collect the inhaled mass of albuterol sulfate?

<p>Absolute filter at the distal tip of the ETT (C)</p> Signup and view all the answers

What is the potential benefit of placing the nebulizer proximal to the ventilator?

<p>Reducing the risk of bacterial contamination in the inspiratory limb (B)</p> Signup and view all the answers

What raises a concern with the heating of medication in the heated humidifier reservoir?

<p>Formation of hazardous vapors at ⱖ 70°C (A)</p> Signup and view all the answers

What is a limitation of the study's results?

<p>Deposited dose reflecting the amount of inhaled aerosol exhaled in vivo (A)</p> Signup and view all the answers

What is a factor that greatly influences aerosol drug delivery during mechanical ventilation, according to the study?

<p>The type of nebulizer used (C)</p> Signup and view all the answers

What did Moraine and co-workers find regarding ipratropium in mechanically ventilated adult patients after 500 ␮g via nebulizer?

<p>No difference in ipratropium in urine based on nebulizer placement (B)</p> Signup and view all the answers

What does reducing the risk of nebulizers with lower residual volume depositing greater volumes of liquid in the inspiratory limb help prevent?

<p>Occlusion of the airway by condensate (D)</p> Signup and view all the answers

What is a potential benefit of isolating the aerosol generator from retrograde contamination?

<p>Reduction in liquid condensate load in the circuit (A)</p> Signup and view all the answers

What does higher bias flow decrease in models of adult and pediatric mechanical ventilation?

<p>Aerosol drug delivery from jet nebulizers (A)</p> Signup and view all the answers

What is a potential concern regarding drugs heated at ⱖ 70°C for extended periods?

<p>Reduced stability and potential formation of hazardous vapors (B)</p> Signup and view all the answers