Untitled Quiz

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What component does the GARRET 36-280 use for monitoring and control?

  • Full Authority Digital Electronic Control (FADEC) (correct)
  • Basic Control Unit
  • Manual Control Panel
  • Analog Control System

What happens when the low oil pressure light illuminates?

  • The APU will automatically shut down. (correct)
  • The APU continues to operate normally.
  • The maintenance light illuminates.
  • A warning is sent to the cockpit.

Which APU model has a 60-second cooldown option?

  • GARRET 36-280
  • SUNDSTRAND APS 2000
  • GARRET 85-129 (correct)
  • None of the above

What does the APU fire warning light indicate?

<p>A fire in the APU (C)</p> Signup and view all the answers

Which model uses a maintenance light to indicate non-critical failures?

<p>Both B and C (D)</p> Signup and view all the answers

What happens when the APU turbine speed exceeds its allowable rpm?

<p>Overspeed light illuminates amber. (A)</p> Signup and view all the answers

What type of compressor does the GARRET 85-129 feature?

<p>Two-stage centrifugal compressor (C)</p> Signup and view all the answers

What does the APU fire control handle do when pulled?

<p>Arms the APU bottle discharge switch. (C)</p> Signup and view all the answers

What type of impellers does the SUNDSTRAND APS 2000 use?

<p>Single centrifugal impeller (A)</p> Signup and view all the answers

Which of the following indicates a critical failure in the APU?

<p>Fault light illuminated amber (D)</p> Signup and view all the answers

What is the purpose of the APU in an airplane?

<p>To make the airplane self-sufficient by providing on ground electrical power (A)</p> Signup and view all the answers

How much KVA can the APU generator supply during flight operation?

<p>50 KVA (D)</p> Signup and view all the answers

What feature automatically transfers power to an alternate generator when needed?

<p>Bus Transfer Switch (D)</p> Signup and view all the answers

Which component converts 115V AC to 28V DC power?

<p>Transformer/Rectifier Units (C)</p> Signup and view all the answers

What is the first action taken when ground power is available?

<p>Engine generators are tripped off generator buses (A)</p> Signup and view all the answers

What is the maximum load displayed by the generator AC ammeter?

<p>60 KVA (B)</p> Signup and view all the answers

Which of the following statements is true about operating the APU bleed air?

<p>Using APU bleed air for air conditioning during takeoff improves takeoff performance (D)</p> Signup and view all the answers

What happens to the APU in the event of overspeed?

<p>It shuts down automatically (D)</p> Signup and view all the answers

What is a feature of the APU designed to minimize exhaust noise heard by passengers?

<p>Acoustically treated air inlet and exhaust duct (C)</p> Signup and view all the answers

What is the role of the Constant Speed Drive (CSD) in the electrical power system?

<p>To maintain a constant speed for the generator (B)</p> Signup and view all the answers

Flashcards

APU Generator Capacity

The APU generator provides 60 KVA of power on the ground and 50 KVA during flight.

Bus Transfer Switch (Automatic)

Automatically switches between generators to maintain power if one fails.

Ground Power Switch

Controls the use of external power source. When ON, engine/APU generators are disabled.

APU Function

Supplies electrical power and bleed air for the airplane, making it self-sufficient on the ground, also used for air conditioning during takeoff.

Signup and view all the flashcards

Constant Speed Drive (CSD)

Drives the generator by each engine, providing 115V, 400Hz, three-phase AC power.

Signup and view all the flashcards

Generator Load Display

The generator AC ammeter shows the load of generator no.1 or 2 in amperes.

Signup and view all the flashcards

APU Starting Method

The APU can be started by the airplane battery or external DC power.

Signup and view all the flashcards

Automatic Bus Transfer System

Increases the reliability of electrical power by automatically transferring power to a backup generator if one fails.

Signup and view all the flashcards

APU Shutdown Triggers

The APU automatically shuts down if there's an overspeed condition, high oil temperature, low oil pressure, or fire.

Signup and view all the flashcards

APU Noise Reduction

Noise is reduced by acoustically treated air inlet and exhaust duct, and by its distance from the cabin.

Signup and view all the flashcards

Garret 85-129 APU

Two-stage centrifugal compressor with a single combustion chamber and inflow turbine. Accessories at the front.

Signup and view all the flashcards

Garret 36-280 APU

Two centrifugal impellers and a single turbine. Monitored/controlled by FADEC (Full Authority Digital Electronic Control).

Signup and view all the flashcards

Sundstrand APS 2000 APU

One centrifugal impeller and turbine.

Signup and view all the flashcards

APU Maintenance Light (non-critical)

Indicates minor problems; FADEC displays specific code for details.

Signup and view all the flashcards

APU Low Oil Pressure

Amber light; APU automatically shuts down.

Signup and view all the flashcards

APU Fault Light (critical)

Amber light; indicates critical issue.

Signup and view all the flashcards

APU Overspeed

Amber light; turbine speed exceeds safe limit.

Signup and view all the flashcards

AC Ammeter

Displays APU generator current.

Signup and view all the flashcards

Exhaust Gas Temp Indicator

Displays APU exhaust gas temperature in Celsius.

Signup and view all the flashcards

APU Fire Protection

APU is enclosed; fire detection system alerts.

Signup and view all the flashcards

Study Notes

Electrical Power System

  • Three electrical generators power the aircraft (two engine driven, one APU driven)
  • APU provides self-sufficiency, supplying on-ground electrical power
  • Automatic Bus Transfer System increases electrical power reliability
  • Onboard power system annunciator and test modules monitor and detect malfunctions

Constant Speed Drive (CSD) and Generator

  • CSD and generators are driven by each engine to produce 115 volts, 400Hz, three-phase AC power.
  • Each CSD supplies 50 KVA.
  • A Variable Speed Constant Frequency (VSCF) generator also produces 50 KVA
  • Transformer/Rectifier units convert 115V AC to 28V DC for other systems.
  • The APU generator provides 50/60 KVA (ground/flight).

APU Generator Bus Switches

  • Connecting APU generator to generator buses #1 or #2.
  • Disconnecting from #1 or #2 generator buses.
  • APU can supply power to both generator buses during ground operations. During flight, APU can only power one generator bus.

Ground Power and Bus Transfer

  • Enables use of ground power if available
  • Tripping engine/APU generators from buses when using ground power.
  • Automatic bus transfer system switches to the opposite generator if needed.
  • Isolates DC systems when the transfer switch is shut off.

Auxiliary Power Unit (APU)

  • Garrett 85-129 and 36-280 models are used.
  • Sundstrand APS 2000 system controls and indicates APU operation.
  • APU mounted on accessory drive pad.
  • 60 KVA ground power, 50 KVA flight operation.
  • Supplies bleed air for air conditioning (and engine startup), optimizing takeoff.

APU Starting

  • APU starts with airplane battery or external DC power.
  • Automatic shutdown happens with overspeed, high oil temperature, low oil pressure, or fire.

Exhaust Noise Reduction

  • Noise reduced by acoustically treated inlet and exhaust ducts, and distance from cabin and ground service points.

APU Access and Maintenance

  • APU readily accessible for inspection, maintenance, or removal through large fuselage access door.

Garrett 85-129 Components

  • Two-stage centrifugal compressor with one radical inflow turbine.
  • Accessories grouped at the front.

Garrett 36-280 Components

  • Two centrifugal impellers and a single centrifugal turbine with a containment ring.

Fire Protection System

  • APU housed in a fire protection shroud to contain fires.
  • Fault causes "DET INOP" light and master warning lights activation.

Controls & Indicators

  • Panel located on the forward head panel
  • Includes APU switch (on/off/start positions, cooldown option)
  • Maintenance light illuminates when oil tank is low.
  • Provides indicators on the APU fire system
  • Includes lights to warn of non-critical and critical failures.
    • Oil low pressure
    • Overspeed condition
    • Critical part failure.
  • Contains AC ammeter to display current.
  • Provides exhaust gas temperature indicator

APU Fire Protection Controls

  • Illuminated red light = APU fire.
  • Fire warning horn when fire detected.
  • APU fire control handle activates system
  • Bottle discharge switch triggers fire suppression.

Pneumatics

  • APU pressurizes air for engine starting
  • Air source obtained from onboard APU or external ground cart.
  • Uses 5th stage compressor air section for flight, and 9th stage for low-engine.
  • Precooler system to control air temperature.
  • APU used for air conditioning up to 17,000 ft altitude

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

Related Documents

Ignition Reviewer Finals PDF

More Like This

Untitled Quiz
37 questions

Untitled Quiz

WellReceivedSquirrel7948 avatar
WellReceivedSquirrel7948
Untitled Quiz
55 questions

Untitled Quiz

StatuesquePrimrose avatar
StatuesquePrimrose
Untitled Quiz
18 questions

Untitled Quiz

RighteousIguana avatar
RighteousIguana
Untitled Quiz
50 questions

Untitled Quiz

JoyousSulfur avatar
JoyousSulfur
Use Quizgecko on...
Browser
Browser