IRC Chapter 1 & 44 Flashcards
35 Questions
100 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

The International Residential Code is applicable to single-family dwellings a maximum of _______ stories in above-grade-plane height.

three

If there is a conflict in the code between a general requirement and a specific requirement, the ______ requirement shall apply.

specific

Provisions of the appendices do not apply unless ________.

specifically adopted

________ is the term used in the IRC to describe the individual in charge of the department of building safety.

<p>building official</p> Signup and view all the answers

The building official has the authority to ____________ the provisions of the code.

<p>interpret</p> Signup and view all the answers

Used materials may be utilized under which one of the following conditions?

<p>when approved by the building official</p> Signup and view all the answers

The building official has the authority to grant modifications to the code _________

<p>for individual cases where the strict letter of the code is impractical</p> Signup and view all the answers

Unless supporting a surcharge, retaining walls having a maximum height of ________ inches do not require a permit.

<p>48</p> Signup and view all the answers

Tests performed by ___________ may be required by the building official where there is insufficient evidence of code compliance.

<p>an approved agency</p> Signup and view all the answers

A permit is not required for the construction of a one-story detached accessory structure when it has a maximum floor area of _________ square feet.

<p>200</p> Signup and view all the answers

Prefabricated swimming pools are subject to a building permit where they have a minimum depth of __________.

<p>24 inches</p> Signup and view all the answers

Unless an extension is authorized, a permit becomes invalid when work does not commence within ___________ after permit issuance.

<p>180 days</p> Signup and view all the answers

The building permit, or a copy of the permit, shall be kept __________ until completion of the project.

<p>at the jobsite</p> Signup and view all the answers

When a building permit is issued, the construction documents shall be approved __________.

<p>in writing or by stamp</p> Signup and view all the answers

Unless otherwise mandated by state or local laws, the approved construction documents shall be retained by the building official for a minimum of _________ from the date of completion of the permitted work.

<p>180 days</p> Signup and view all the answers

Which one of the following inspections is not specifically identified by the International Residential Code as a required inspection?

<p>energy efficiency inspection</p> Signup and view all the answers

Whose duty is it to provide access to work in need of inspection?

<p>the person requesting the inspection</p> Signup and view all the answers

The certificate of occupancy shall contain all of the following information except:

<p>the maximum occupant load</p> Signup and view all the answers

A temporary certificate of occupancy is valid for what period of time?

<p>a period set by the building official</p> Signup and view all the answers

The board of appeals is not authorized to rule on an appeal based on a claim that ________.

<p>a code requirement should be waived</p> Signup and view all the answers

The membership of the board of appeals _________

<p>shall be knowledgeable of building construction</p> Signup and view all the answers

A permit is not required for construction of a fence with a maximum height of _________ feet.

<p>7</p> Signup and view all the answers

When a stop work order is issued, it shall be given to any of the following individuals except for the __________.

<p>permit applicant</p> Signup and view all the answers

Which of the following standards is applicable for factory-built fireplaces?

<p>UL 127-2011</p> Signup and view all the answers

ACI 318-14 is a reference standard addressing _________.

<p>structural concrete</p> Signup and view all the answers

All of the following issues are specifically identified for achieving the purpose of the International Residential Code, except for _______.

<p>usability and accessibility</p> Signup and view all the answers

A permit is not required for installation of a window awning provided the awning projects a maximum of ______ inches from the exterior wall and does not require additional support.

<p>54</p> Signup and view all the answers

Where a self-contained refrigeration system contains a maximum of __________ pound(s) of refrigerant, a permit is not required.

<p>10</p> Signup and view all the answers

It is the duty of the ____________ or their agent to notify the building official that work is ready for inspection.

<p>permit holder</p> Signup and view all the answers

What is the role of the building official in relationship to the board of appeals?

<p>ex officio member</p> Signup and view all the answers

Where the enforcement of a code provision would violate the conditions of an appliance's listing, the conditions of the listing ________.

<p>shall apply</p> Signup and view all the answers

Inspection reports shall be retained in the official records for what minimum period?

<p>the time required for the retention of public records</p> Signup and view all the answers

Which of the following reasons is not specifically identified by the code as authority to suspend or revoke a permit?

<p>required inspections have not been performed</p> Signup and view all the answers

A permit for a temporary structure is limited as to time of service, but shall not be allowed for more than ___________ days.

<p>180</p> Signup and view all the answers

The issuance of a certificate of occupancy is not required for what maximum size of accessory building?

<p>all accessory buildings are exempt</p> Signup and view all the answers

Study Notes

International Residential Code (IRC) Key Facts

  • Applicable to single-family dwellings up to three stories in height (R101.2).
  • In case of conflict between general and specific requirements, the specific requirement prevails (R102.1).
  • Provisions of appendices apply only if specifically adopted (R102.5).
  • The building official oversees the department of building safety (R103.1) and has the authority to interpret code provisions (R104.1).
  • Used materials may be approved for use by the building official (R104.9.1).
  • The official can grant modifications to code requirements for individual impractical cases (R104.10).

Permits and Inspections

  • Retaining walls up to 48 inches tall do not require a permit unless they support a surcharge (R105.2).
  • A permit is unnecessary for one-story detached structures with a maximum area of 200 square feet (R105.2).
  • Prefabricated swimming pools require a permit if they are at least 24 inches deep (R105.2).
  • A building permit becomes invalid if work does not start within 180 days after issuance (R105.5).
  • The permit must be kept on-site throughout the project (R105.7).
  • Construction documents must be approved in writing or by stamp upon permit issuance (R106.3.1).
  • Approved construction documents must be retained for a minimum of 180 days post-completion (R106.5).

Inspections and Certificate of Occupancy

  • Energy Efficiency Inspection is not an explicitly required inspection under IRC (R109.1).
  • The person requesting an inspection is responsible for providing access for inspectors (R109.3).
  • A certificate of occupancy does not include occupant load details (R110.3).
  • Temporary certificates of occupancy are valid for a period determined by the building official (R110.4).

Board of Appeals

  • The board of appeals cannot waive code requirements (R112.2).
  • Members must be knowledgeable in building construction (R112.3).
  • The building official serves as an ex officio member of the board (R112.1).

Additional Key Points

  • A fence up to 7 feet in height does not require a permit (R105.2).
  • Stop work orders must be issued to responsible individuals, excluding the permit applicant (R114.1).
  • Factory-built fireplaces must adhere to standard UL 127-2011 (Chapter 44).
  • ACI 318-14 pertains to structural concrete standards (Chapter 44).
  • Usability and accessibility are not explicitly addressed as objectives of the IRC (R101.3).
  • A window awning projecting up to 54 inches does not require a permit (R105.2).
  • Self-contained refrigeration systems with 10 pounds of refrigerant or less do not require permits (R105.2).
  • The permit holder, or their agent, must notify the building official for inspections (R109.3).
  • Conditions of an appliance's listing take precedence if they conflict with code provisions (R102.4 exception).
  • Inspection reports must be retained as required for public records (R104.7).
  • Permits can be suspended or revoked for numerous reasons, except for unperformed required inspections (R105.6).
  • Temporary structure permits are valid for a maximum of 180 days (R107.1).
  • No certificate of occupancy is needed for accessory buildings of any size (R110.1 exception 2).

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

Description

Test your knowledge of the International Residential Code with these flashcards covering key concepts from Chapters 1 and 44. Each card presents essential definitions and requirements to help you understand the code better. Perfect for students and professionals in the construction field.

More Like This

Use Quizgecko on...
Browser
Browser