The International Residential Code is applicable to single-family dwellings a maximum of _______ stories in above-grade-plane height.

three

If there is a conflict in the code between a general requirement and a specific requirement, the ______ requirement shall apply.

specific

Provisions of the appendices do not apply unless ________.

specifically adopted

________ is the term used in the IRC to describe the individual in charge of the department of building safety.

<p>building official</p> Signup and view all the answers

The building official has the authority to ____________ the provisions of the code.

<p>interpret</p> Signup and view all the answers

Used materials may be utilized under which one of the following conditions?

<p>when approved by the building official</p> Signup and view all the answers

The building official has the authority to grant modifications to the code _________

<p>for individual cases where the strict letter of the code is impractical</p> Signup and view all the answers

Unless supporting a surcharge, retaining walls having a maximum height of ________ inches do not require a permit.

<p>48</p> Signup and view all the answers

Tests performed by ___________ may be required by the building official where there is insufficient evidence of code compliance.

<p>an approved agency</p> Signup and view all the answers

A permit is not required for the construction of a one-story detached accessory structure when it has a maximum floor area of _________ square feet.

<p>200</p> Signup and view all the answers

Prefabricated swimming pools are subject to a building permit where they have a minimum depth of __________.

<p>24 inches</p> Signup and view all the answers

Unless an extension is authorized, a permit becomes invalid when work does not commence within ___________ after permit issuance.

<p>180 days</p> Signup and view all the answers

The building permit, or a copy of the permit, shall be kept __________ until completion of the project.

<p>at the jobsite</p> Signup and view all the answers

When a building permit is issued, the construction documents shall be approved __________.

<p>in writing or by stamp</p> Signup and view all the answers

Unless otherwise mandated by state or local laws, the approved construction documents shall be retained by the building official for a minimum of _________ from the date of completion of the permitted work.

<p>180 days</p> Signup and view all the answers

Which one of the following inspections is not specifically identified by the International Residential Code as a required inspection?

<p>energy efficiency inspection</p> Signup and view all the answers

Whose duty is it to provide access to work in need of inspection?

<p>the person requesting the inspection</p> Signup and view all the answers

The certificate of occupancy shall contain all of the following information except:

<p>the maximum occupant load</p> Signup and view all the answers

A temporary certificate of occupancy is valid for what period of time?

<p>a period set by the building official</p> Signup and view all the answers

The board of appeals is not authorized to rule on an appeal based on a claim that ________.

<p>a code requirement should be waived</p> Signup and view all the answers

The membership of the board of appeals _________

<p>shall be knowledgeable of building construction</p> Signup and view all the answers

A permit is not required for construction of a fence with a maximum height of _________ feet.

<p>7</p> Signup and view all the answers

When a stop work order is issued, it shall be given to any of the following individuals except for the __________.

<p>permit applicant</p> Signup and view all the answers

Which of the following standards is applicable for factory-built fireplaces?

<p>UL 127-2011</p> Signup and view all the answers

ACI 318-14 is a reference standard addressing _________.

<p>structural concrete</p> Signup and view all the answers

All of the following issues are specifically identified for achieving the purpose of the International Residential Code, except for _______.

<p>usability and accessibility</p> Signup and view all the answers

A permit is not required for installation of a window awning provided the awning projects a maximum of ______ inches from the exterior wall and does not require additional support.

<p>54</p> Signup and view all the answers

Where a self-contained refrigeration system contains a maximum of __________ pound(s) of refrigerant, a permit is not required.

<p>10</p> Signup and view all the answers

It is the duty of the ____________ or their agent to notify the building official that work is ready for inspection.

<p>permit holder</p> Signup and view all the answers

What is the role of the building official in relationship to the board of appeals?

<p>ex officio member</p> Signup and view all the answers

Where the enforcement of a code provision would violate the conditions of an appliance's listing, the conditions of the listing ________.

<p>shall apply</p> Signup and view all the answers

Inspection reports shall be retained in the official records for what minimum period?

<p>the time required for the retention of public records</p> Signup and view all the answers

Which of the following reasons is not specifically identified by the code as authority to suspend or revoke a permit?

<p>required inspections have not been performed</p> Signup and view all the answers

A permit for a temporary structure is limited as to time of service, but shall not be allowed for more than ___________ days.

<p>180</p> Signup and view all the answers

The issuance of a certificate of occupancy is not required for what maximum size of accessory building?

<p>all accessory buildings are exempt</p> Signup and view all the answers

Study Notes

International Residential Code (IRC) Key Facts

  • Applicable to single-family dwellings up to three stories in height (R101.2).
  • In case of conflict between general and specific requirements, the specific requirement prevails (R102.1).
  • Provisions of appendices apply only if specifically adopted (R102.5).
  • The building official oversees the department of building safety (R103.1) and has the authority to interpret code provisions (R104.1).
  • Used materials may be approved for use by the building official (R104.9.1).
  • The official can grant modifications to code requirements for individual impractical cases (R104.10).

Permits and Inspections

  • Retaining walls up to 48 inches tall do not require a permit unless they support a surcharge (R105.2).
  • A permit is unnecessary for one-story detached structures with a maximum area of 200 square feet (R105.2).
  • Prefabricated swimming pools require a permit if they are at least 24 inches deep (R105.2).
  • A building permit becomes invalid if work does not start within 180 days after issuance (R105.5).
  • The permit must be kept on-site throughout the project (R105.7).
  • Construction documents must be approved in writing or by stamp upon permit issuance (R106.3.1).
  • Approved construction documents must be retained for a minimum of 180 days post-completion (R106.5).

Inspections and Certificate of Occupancy

  • Energy Efficiency Inspection is not an explicitly required inspection under IRC (R109.1).
  • The person requesting an inspection is responsible for providing access for inspectors (R109.3).
  • A certificate of occupancy does not include occupant load details (R110.3).
  • Temporary certificates of occupancy are valid for a period determined by the building official (R110.4).

Board of Appeals

  • The board of appeals cannot waive code requirements (R112.2).
  • Members must be knowledgeable in building construction (R112.3).
  • The building official serves as an ex officio member of the board (R112.1).

Additional Key Points

  • A fence up to 7 feet in height does not require a permit (R105.2).
  • Stop work orders must be issued to responsible individuals, excluding the permit applicant (R114.1).
  • Factory-built fireplaces must adhere to standard UL 127-2011 (Chapter 44).
  • ACI 318-14 pertains to structural concrete standards (Chapter 44).
  • Usability and accessibility are not explicitly addressed as objectives of the IRC (R101.3).
  • A window awning projecting up to 54 inches does not require a permit (R105.2).
  • Self-contained refrigeration systems with 10 pounds of refrigerant or less do not require permits (R105.2).
  • The permit holder, or their agent, must notify the building official for inspections (R109.3).
  • Conditions of an appliance's listing take precedence if they conflict with code provisions (R102.4 exception).
  • Inspection reports must be retained as required for public records (R104.7).
  • Permits can be suspended or revoked for numerous reasons, except for unperformed required inspections (R105.6).
  • Temporary structure permits are valid for a maximum of 180 days (R107.1).
  • No certificate of occupancy is needed for accessory buildings of any size (R110.1 exception 2).