Questions and Answers

What type of attack can be conducted by malicious users due to the vulnerability found in Schneider Electric Accutech Manager?

  • Cross-site scripting (XSS) attack
  • SQL injection attack (correct)
  • Denial of Service (DoS) attack
  • Man-in-the-middle (MitM) attack

Which port is susceptible to the vulnerability in Schneider Electric Accutech Manager?

  • Port 2536 (correct)
  • Port 80
  • Port 8080
  • Port 443

For which versions of the Schneider Electric Accutech Manager was the vulnerability reported?

  • Version 2.00.4 and below (correct)
  • Version 3.0.0 and above
  • Version 2.00.4 and above
  • Version 1.5.7 and above

What is the purpose of deploying FortiGate in offline IDS mode?

<p>To monitor network segments and detect known attacks (B)</p> Signup and view all the answers

In which mode does FortiGate act as a network sensor?

<p>Offline IDS (A)</p> Signup and view all the answers

What is the function of FortiGate in inline IPS and IDS mode?

<p>To detect and block network attacks (A)</p> Signup and view all the answers

What is the alternative name for the mode in which vulnerable devices are protected by FortiGate?

<p>Virtual patching mode (B)</p> Signup and view all the answers

What type of capability does FortiGate include in offline IDS mode?

<p>Packet capture capability (B)</p> Signup and view all the answers

What is the purpose of including security profiles in FortiGate?

<p>To increase cybersecurity visibility (D)</p> Signup and view all the answers

What is the function of FortiGate in IPS mode?

<p>To detect and block network attacks (A)</p> Signup and view all the answers

What is the default action for the regular signature database?

<p>Block the detected attack (B)</p> Signup and view all the answers

Why is the extended signature database not available for certain FortiGate models?

<p>Due to performance impact and resource limitations (B)</p> Signup and view all the answers

What is the default status of the industrial signature database?

<p>Disabled (D)</p> Signup and view all the answers

When might enabling the extended signatures database be necessary?

<p>For high-security O.T networks (C)</p> Signup and view all the answers

What does the IPS signature database contain?

<p>Signatures for common attacks (A)</p> Signup and view all the answers

What action should be taken to enable the industrial signature database?

<p>Use the CLI command: config ips global set exclude-signatures none end (A)</p> Signup and view all the answers

What does the FortiGuard SCADA IPS filter provide?

<p>An example of the IPS sensor (B)</p> Signup and view all the answers

What is the primary consideration for enabling the extended signature database?

<p>Performance impact and attack nature (B)</p> Signup and view all the answers

What does the extended signature database contain?

<p>Additional signatures for performance-intensive attacks (D)</p> Signup and view all the answers

Why might the extended signature database not be suitable for certain FortiGate models?

<p>Due to size and resource limitations (A)</p> Signup and view all the answers