Indian Railways Signal Engineering Drawings

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

According to the IRSEM, what does the number '19' represent in 'Drg no: 19-D3'?

  • Chapter number (correct)
  • Drawing number
  • Page number
  • Appendix number

According to Drg. No.12-D1, what is the fish tailed bar width of a Warner signal?

  • 125 mm
  • 150 mm
  • 175 mm (correct)
  • 200 mm

According to Drg. No.12-D1, what is the bar width of a Shunt signal (miniature arm type)?

  • 175 mm
  • 150 mm
  • 125 mm (correct)
  • 100 mm

According to Drg. No.12-D1, what is the outside diameter of the Diameter of ring of Goods signal?

<p>450 mm (D)</p> Signup and view all the answers

According to Drg. No.12-D1, what should be th height of centre of disc from rail level in 'S' marker for outlying Sidings?

<p>2000 mm (A)</p> Signup and view all the answers

According to Drg. No.12-D1, what is the band length of a caution indicator?

<p>400 mm (C)</p> Signup and view all the answers

According to Drg. No.12-D1, height from rail level to bottom of board for speed indicator measures:

<p>2000 mm (C)</p> Signup and view all the answers

As specified in Drg.No.15-D1, what is the approximate number of length of 6 MM DIA. M.S.ROD required, in Reinforcement details for RCC cable marker?

<p>1650 MM (B)</p> Signup and view all the answers

As per the details mentioned in Drg.No.15-D1 to maintain the vertical M.S. Rods. What should be the approximate height from ground level?

<p>150 MM (A)</p> Signup and view all the answers

In reference to Drg.No.15-D2, The cement concrete blocks shall be provided how many meters interval?

<p>2 meters (B)</p> Signup and view all the answers

According to Drg.No.15-D3, the RCC duct should be buried at a minimum depth of:

<p>600mm (D)</p> Signup and view all the answers

As per Drg.No.15-D3, the GI mild steel wire for reinforcement shall be confirmining to:

<p>IS:280-2006 (C)</p> Signup and view all the answers

According to Drg.No.15-D4, what is the Outer Diameter (OD) of DWC Split Pipe?

<p>120 mm (B)</p> Signup and view all the answers

What is the minimum depth for burying trunking as per Drg.No.15-D3 Note 1?

<p>600 mm (C)</p> Signup and view all the answers

According to the Drg.No.15-D5, what is the Depth from rail level and flange level?

<p>1000 mm (A)</p> Signup and view all the answers

What does C01T represent in the context of the cable core plan for a 4-road station with PI (Drg.No.15-D9)?

<p>Location code or identifier for cable termination points (A)</p> Signup and view all the answers

According to Drg. No.15-D6, What is Minimum thickness of steel sheet for trough fabrication?

<p>1.6 mm (D)</p> Signup and view all the answers

In reference to drawing Drg.No.16-D1 (Sheet 1 of 4), what is the function of the phase selector?

<p>To select the appropriate phase from 3-phase supply (B)</p> Signup and view all the answers

Refer to Drg.No.15-D10, what is the shape of conductor used for earthing electric lifting barrier?

<p>Flat conductor (B)</p> Signup and view all the answers

In relation to Drg.No.18-D1, what is the recommended height of the windows above floor level?

<p>0.91 M (C)</p> Signup and view all the answers

What does 'SMR' stand for in the context of contact analysis format (8F/8B) as per Drg.No. 21-D7?

<p>Signal Master Relay (C)</p> Signup and view all the answers

Refer to Drg.no.21-D8 concerning bonding and earthing connections for signalling equipments and state what should be the maximum length of the 16mm Sq. Copper Cable connected to it?

<p>1.5 meters (C)</p> Signup and view all the answers

According to the Signal Clearance Diagram to Suit 25 KV AC Traction for Tangent Tracks and Curved Tracks with S.E.60 vide Drg No. 22-D1, what is the Pento Axis values?

<p>4725 (B)</p> Signup and view all the answers

According to the reference in Drg.No.22 - D5 related to Colour Light Signal which is the correct value for Signal Height?

<p>5870 MM (B)</p> Signup and view all the answers

According to Drg. No. 22-D7, what is the OHE structure setting when there is no Horizontal Route Indication is at length of:

<p>4.0 M (D)</p> Signup and view all the answers

According to Drg.No.15-D9 (Sheet 1 of 3), for Spare BPAC system, which cable sizes are used in the Cable core plan for a 4-Road station with PI?

<p>2Cx25Sq.mm-B/N24V (B)</p> Signup and view all the answers

Using Drg. No.15-D9 (Sheet 1 of 3) as a reference, what is the quantity 12C cable required to 12C-D01?

<p>8 (A)</p> Signup and view all the answers

According to Drg.No.15-D9 (Sheet 1 of 3), which cable is provided for quick transfer of circuits?

<p>30-core (C)</p> Signup and view all the answers

What purpose does the 2Cx70Sqmm AC 230V cable serve in the context of a 6-road station with distributed EI, according to Drg.No.15-D9 (Sheet 2 of 3)?

<p>For IPS power supply (D)</p> Signup and view all the answers

What is the purpose of providing plastic reflectors on a goods warning board, according to Drg.No.12-D1?

<p>Enhance visibility (B)</p> Signup and view all the answers

As per the Drg.No.12-D1, what indicates that a trap is open or that there is derailment on the line?

<p>Point indicator - Target Type (D)</p> Signup and view all the answers

For determining cable laying depth when a rock is faced what is the minimum depth?

<p>300 mm (D)</p> Signup and view all the answers

What does the 6 QUAD refer to, regarding the number of cables in Automatic Block Signalling Scheme as per Drg No 20-D1?

<p>The core capacity of each Signaling cable (C)</p> Signup and view all the answers

According to Drg. No.12-D1, what is the approximate height (in mm) of the letter ‘D’ on a Dock Signal?

<p>450 (D)</p> Signup and view all the answers

As per Drg. No.12-D1, what is the approximate width of the bar used for a Shunt signal (disc type)?

<p>150 mm (C)</p> Signup and view all the answers

As per Drg.No.12-D1, what bands are used on for outlying sidings?

<p>Black &amp; white bands alternately (B)</p> Signup and view all the answers

According to Drg. No.12-D1, what is the minimum height of the letter 'L' used in Loco Shunt signal(disc type)

<p>380 mm (B)</p> Signup and view all the answers

As specified in Drg.No.15-D1, What should be the 6 MM DIA. M.S.Rod length, in Reinforcement details for RCC cable marker?

<p>Approximately 1650 mm (C)</p> Signup and view all the answers

In reference to Drg.No.15-D1 regarding RCC cable markers, what's the number of M.S. TIE RODS are of length 250 ΜΜ?

<p>2 Nos (B)</p> Signup and view all the answers

According to Drg.No.15-D1, what is the diameter of vertical M.S. Rods used in concrete skirting for placing on RCC cable marker?

<p>8 mm (B)</p> Signup and view all the answers

According to Drg. No.15-D2, what should be the width and height for cement concrete when rock faced at 300 MM depth from ground level?

<p>300 MM x 300 MM (A)</p> Signup and view all the answers

According to the Drg.No.15-D2, If the cement concrete blocks shall be provided at 2 metres interval when rock is faced at 400 mm depth. whats the cement concrete block dimension?

<p>300MM x 300MM x 300MM (C)</p> Signup and view all the answers

As per Drg.No.15-D3, the High strength deformed steel bar code is:

<p>IS: 11786 (A)</p> Signup and view all the answers

According to Drg.No.15-D3, What is the maximum size of coarse aggregate in mm for M-25 grade of concrete?

<p>10 mm (D)</p> Signup and view all the answers

According to the Drg.No.15-D3, In the drawing of RCC Split Pipe, what is OD?

<p>150-OD (A)</p> Signup and view all the answers

According to Drg No.15-D4, the value of ID for DWC Split pipe?

<p>103.5-ID (D)</p> Signup and view all the answers

In Drg.No.15-D4, what is the standard length of the DWC Split Pipe?

<p>6 Mtrs (D)</p> Signup and view all the answers

In reference to Drg.No.19-D10, what is the radius of the Clamp used for Shunt Signal?

<p>47R (B)</p> Signup and view all the answers

According to Drg.No.19-D10, what color is specified for reflector ‘G’?

<p>Yellow (C)</p> Signup and view all the answers

According to Drg.No.19-D10, which grade of retro-reflective sheet is mentioned?

<p>High-Intensity Grade (C)</p> Signup and view all the answers

Refer to Drg no. 19-D10; What is the thickness of film used for the 'A' marker Retro Reflective Sheet?

<p>0.3 mm (B)</p> Signup and view all the answers

According to the Interlocking Control Table (Drg.No.8-D2, Sheet 2 of 4), what is the clearing time release of S01 Signal from DN Main aspect

<p>120 SEC (A)</p> Signup and view all the answers

Using the Interlocking Control Table Drg.No.8-D2 (Sheet 1 of 4) of ‘4 ROAD STATION ON DOUBLE LINE’ how many no .of Roads available in station?

<p>4 (A)</p> Signup and view all the answers

According to ICT.SCR.GTL.VPL.Ø2 VERSION Ø1 in Drg.No.8-D2 (Sheet 4 of 4), what is the Time release value after 120 sec. Signal for Up Main (SH41)?

<p>202 (A)</p> Signup and view all the answers

Based on Drg No.8-D2 (Sheet 2 of 4), what is the interlocking control table sheet number for the 4 Road Station?

<p>ØØ2 (B)</p> Signup and view all the answers

According to Drg No.8-D2 what is the Signal aspect name in the interlocking control table for S01 when the tracks are occupied by TCAS/TPWS?

<p>Green (A)</p> Signup and view all the answers

As stated in drg no.8-D2(sheet 1 of 4) ICT.SCR.GTL.VPL.Ø2 what exactly is the meaning of VPL?

<p>Venkatampalle (D)</p> Signup and view all the answers

What does ICT.SCR.GTL represent in the Interlocking Control Table mentioned on Drg.No.8-D2?

<p>Interlocking Control Table (C)</p> Signup and view all the answers

In reference to Drg no.21-D7, what is denoted by the term ‘R1’ in the context of Relay Contact Analysis?

<p>Rack -1 - ‘F’ - Row - Second relay (A)</p> Signup and view all the answers

In the relay contact analysis format, what determines the ordering and layout of components within the system according to Drg.No. 21-D1?

<p>Functional logic (D)</p> Signup and view all the answers

Using Drg. No.16-D1 (Sheet 4 of 4) as reference, determine the Power Supply arrangement using 110VDC, what 110VDC to be connected to?

<p>Invertor (D)</p> Signup and view all the answers

According to Drg. No.16-D1 (Sheet 1 of 4), the Goomty IPS Indication to be repeated To?

<p>ASM (B)</p> Signup and view all the answers

As per Drg. no.16-D1 what is purpose 2 cx70 sqmm ac 230v in distribution?

<p>Supply for ips (D)</p> Signup and view all the answers

What should be done and must followed according to The Drg no:22-D1 used for curves in for maximum cant?

<p>Curves drawn to the maximum cant (B)</p> Signup and view all the answers

Where is lightning protection typically placed between, given the power supply systems drawing Drg. No. 16-D1?

<p>Before and after the power grid (D)</p> Signup and view all the answers

Where can details of DC-DC panel converter allotments be found regarding Drg. No 16-D1?

<p>Details as per the site requirements (C)</p> Signup and view all the answers

According to Drg. No. 17-D1, what is the recommended depth, in meters, at which track lead cables should be laid from the ground level?

<p>1 (C)</p> Signup and view all the answers

According to Drg.No.17 - D3, The cross bonding is required Double Line and Single Line Track Circuits. In Single line which bonding has been used

<p>Earth wire (D)</p> Signup and view all the answers

With reference to Drg.No.18-D1, what shape are the doors to be to maintain Goomty layout?

<p>flush type (C)</p> Signup and view all the answers

What is indicated for a Single Line Block with MSDAC in Drg.No.18-D3( Sheet 1 of 2)

<p>Signal cable (C)</p> Signup and view all the answers

According to Drg. No.18-D1, what is the height recommendation for the windows in the IB Hut Layout (Double Line) from the floor level?

<p>0.91 m (D)</p> Signup and view all the answers

In the IRSEM document numbering convention, if '19' represents the 'Chapter Number', and 'D3' indicates the 'third drawing', what does 'Drg no: 21-D5' signify?

<p>The fifth drawing of Chapter 21. (D)</p> Signup and view all the answers

According to Drg.No.12-D1, what is the approximate width of the bar used for a Warner signal?

<p>175 mm (B)</p> Signup and view all the answers

According to Drg. No.12-D1, what is the approximate height of the letter 'L' on a Loco Shunt signal (disc type)?

<p>380 mm (A)</p> Signup and view all the answers

According to Drg. No.15-D1, what is the approximate length of 6 MM DIA. M.S.Rod required for Reinforcement details for RCC cable marker?

<p>450 mm (D)</p> Signup and view all the answers

According to Drg.No.15-D2, if rock is encountered at a depth of 400mm from ground level during cable laying, at what intervals should cement concrete blocks be provided?

<p>At 2-meter intervals (A)</p> Signup and view all the answers

According to Drg.No.15-D3, what is the maximum permissible size of coarse aggregate for M-25 grade concrete used in RCC duct construction?

<p>10 mm (B)</p> Signup and view all the answers

According to Drg.No.15-D4, what does 'ID' signify in the context of DWC Split Pipe dimensions?

<p>Inner Diameter (D)</p> Signup and view all the answers

According to Drg.No.19-D10, what is the specified thickness of the film used for the 'A' marker Retro Reflective Sheet?

<p>0.3 mm (B)</p> Signup and view all the answers

According to Drg.No.21-D7, what does 'SMR' stand for in the context of Relay Contact Analysis?

<p>Station Master Relay (D)</p> Signup and view all the answers

According to Drg.No.17-D1, at what approximate depth should track lead cables be laid from the ground level?

<p>1.0 meter (C)</p> Signup and view all the answers

According to Drg.No.18-D1, what is the recommended minimum width for doorways in an IB Hut layout?

<p>0.9 m (A)</p> Signup and view all the answers

According to Drg.No.15-D9 (Sheet 1 of 3), for a 4-Road station with PI, which type of cable is designated for quick transfer of circuits in case of failures?

<p>30C cable (D)</p> Signup and view all the answers

According to Drg No. 20-D1, what is the purpose of providing '6 QUAD' cables in Automatic Block Signalling Schemes?

<p>To facilitate BPAC system communication (A)</p> Signup and view all the answers

Referencing Drg.No.16-D1 (Sheet 1 of 4), where is the lightning protection typically placed in the power supply arrangement for distributed EI?

<p>At both central and HUT/Goomty locations (C)</p> Signup and view all the answers

According to Drg. No.12-D1, what visual indication confirms a trap is open or derailment on a line in mechanical signalling?

<p>A red circular indicator (C)</p> Signup and view all the answers

According to Drg.No.17-D3, which type of bonding is recommended for earth wire continuity in Single Line Track Circuits?

<p>Cross Bonding (A)</p> Signup and view all the answers

According to Drg.No.19-D10, what is the specified retro-reflective sheet color for the 'G' marker?

<p>Yellow (D)</p> Signup and view all the answers

According to Drg.No.15-D5, what is the primary function of the 'PIPE' indicated in the drawing for Road/Track crossing?

<p>To encase and protect signal cables (B)</p> Signup and view all the answers

According to Drg.No.21-D1, what is the main determining factor for the layout and ordering of components in a relay contact analysis format?

<p>Logical signal flow (B)</p> Signup and view all the answers

According to Drg.No.16-D1 (Sheet 4 of 4), if the spare IPS (IPS-1) is unavailable, which IPS can be used as a substitute in a distributed EI power supply arrangement?

<p>IPS-2 (D)</p> Signup and view all the answers

According to the preface, what is the primary purpose of the Drawings Booklet within the IRSEM?

<p>To offer guidance which can be customized based on specific site conditions and railway practices. (D)</p> Signup and view all the answers

What factors should be considered when customizing the drawings in the IRSEM Drawings Booklet?

<p>Site conditions, type and size of equipment, Zonal Railways practices, and Railway Board/RDSO guidelines. (D)</p> Signup and view all the answers

In the context of IRSEM, what is the significance of consulting relevant SEM chapters alongside the drawings?

<p>It ensures correct interpretation and application of the drawings in accordance with the specific guidelines. (B)</p> Signup and view all the answers

What is the primary intention behind including examples or drawings of particular equipment in Appendix II of IRSEM?

<p>To provide guidance and information to signal engineers and technicians. (A)</p> Signup and view all the answers

According to Drg No.15-D3, what material is specified for reinforcement in RCC split pipes?

<p>8 SWG GI mild steel wire conforming to IS:280-2006. (C)</p> Signup and view all the answers

According to Drg No.15-D3, what type of concrete should be used for RCC Duct construction?

<p>M-25 grade of concrete. (A)</p> Signup and view all the answers

According to Drg No.15-D3, what type of cement code is recommended conforming to IS code?

<p>OPC of 43 grade. (B)</p> Signup and view all the answers

As depicted, what does Section AB represent in Drg.No.15-D5, when a road crosses signaling tracks?

<p>A profile displaying the layering and composition of the road structure, pipe and cable placement in trench. (D)</p> Signup and view all the answers

What is the recommended approach to dealing with welding on a cable trough for a metallic bridge as outlined in Drg.No.15-D6

<p>Avoid welding on any component during fabrication. (A)</p> Signup and view all the answers

What specific instruction related to nuts is provided for cable trough installation of metallic bridge as per Drg.No.15-D6?

<p>Burr the thread of the bolt after tightening nuts for fixing strap to prevent theft. (C)</p> Signup and view all the answers

In a typical station layout with distributed EI using 110VDC, which component directly supplies power to the track circuits, as inferred from Drg. No. 16-D1?

<p>The DC-DC panel converters. (A)</p> Signup and view all the answers

According to Drg. No.16-D1, What does the redundant path using 2Cx70Sqmm AC 230V achieve in a distributed EI system?

<p>Ensures continuous power supply to critical equipment in case of a cable fault. (D)</p> Signup and view all the answers

What action does green color coding denote in the power supply arrangement drawings, according to general notes from drawings?

<p>Denotes Cable wire is more than 50 sq.mm Power Cable. (A)</p> Signup and view all the answers

What is the main functionality performed by the equipment within the 'Inspection Chamber' in Drg.No. 19-D5 related to earthing?

<p>Serving as an access point for checking and maintaining the earthing electrode connections. (A)</p> Signup and view all the answers

According to Drg. No. 19-D10, How film thickness is applicable to retro reflective sheet?

<p>Film thickness 0.3 mm. (C)</p> Signup and view all the answers

According to Drg. No 18-D2, In IB signalling, If alterations are to be carried out in existing interlocking then which status is transferred?

<p>Signals required between IB stations transferred using MSDAC. (A)</p> Signup and view all the answers

According to the general material specifications of the signal markers depicted in Drg. No. 19-D10, what type of reflective material is prescribed?

<p>High intensity grade reflective sheet. (A)</p> Signup and view all the answers

With reference to typical wiring schemes, what wiring cable will be connected to earth in S&T installation as per drawing?

<p>35mm2 Copper Cable. (C)</p> Signup and view all the answers

What should be the mixing ratio for casting a foundation with sand and Jelly with Cement as per Drg.No.15-D2?

<p>Mixing ratio 1:3:6 (D)</p> Signup and view all the answers

Where can detailes of Dc-Dc panel converter Allotments be found about Distributed EI?

<p>Allotments given as per site requirement. (B)</p> Signup and view all the answers

About Interlocking, Where can all dimensions checked before starting work?

<p>In Drg.No:8-D1 with SWR datas must follow. (A)</p> Signup and view all the answers

Which material will be suitable for Burrying Adjacent to the Tracks in trenches with minimum depth?

<p>RCC Split Pipe. (B)</p> Signup and view all the answers

According to the preface, what is the suggested approach for using the Drawings Booklet concerning customization?

<p>It should be suitably customized based on site conditions and equipment types. (D)</p> Signup and view all the answers

What broader considerations should guide the customization of drawings in the IRSEM Drawings Booklet?

<p>Railway Board/RDSO's guidelines, reliability, maintainability, safety, and industry practices. (A)</p> Signup and view all the answers

According to the content, what should the signal engineer primarily consult alongside the Drawings Booklet?

<p>Relevant provisions in the concerned Chapter of SEM. (C)</p> Signup and view all the answers

What is the stated purpose of including specific equipment examples in Appendix II (the Drawings Booklet)?

<p>To offer guidance and information to signal engineers and technicians. (A)</p> Signup and view all the answers

According to Drg.No.15-D3 regarding RCC duct construction, which document specifies the requirements for high strength deformed steel bars?

<p>IS: 11786 (D)</p> Signup and view all the answers

According to Drg.No.15-D3, what type of cement is preferred for RCC duct Constrution?

<p>43 grade OPC conforming to IS: 8112- 1989 (D)</p> Signup and view all the answers

According to Drg.No.15-D3, which Indian Standard (IS) code should be used for Ordinary Portland Cement used in RCC duct construction?

<p>IS:8112-1989 (C)</p> Signup and view all the answers

Refer to Drg.No.15-D5, What does section AB primarily illustrate in the context of a road crossing signalling tracks?

<p>Cable laying depth and protection method. (A)</p> Signup and view all the answers

What specific instruction is emphasized regarding welding on cable troughs for metallic bridges, according to Drg.No.15-D6?

<p>No welding should be done on any component during fabrication. (B)</p> Signup and view all the answers

According to Drg.No.15-D6, relating to cable trough installation on metallic bridges, what action should be taken concerning the nuts after they are tightened for fixing the strap?

<p>The thread of the bolt may be burred to prevent theft. (A)</p> Signup and view all the answers

Based on Drg. No. 16-D1, In a distributed EI system with 110VDC, what component directly supplies power to the track circuits?

<p>The DC-DC converters. (C)</p> Signup and view all the answers

According to Drg. No. 16-D1, in a distributed Electronic Interlocking (EI) system. What does the redundant power path using 2Cx70Sqmm AC 230V cables primarily ensure?

<p>Maintains power supply in case of primary supply failure. (B)</p> Signup and view all the answers

Based on the general notes within the drawings, what does green coloring signify in power supply arrangements?

<p>Wiring or cable that is of a power cable more than 50 sq.mm. (C)</p> Signup and view all the answers

According to Drg. No. 19-D5, what is the primary function of the components within the 'Inspection Chamber' related to earthing?

<p>To provide access for inspection and maintenance of earthing connections. (A)</p> Signup and view all the answers

According to Drg. No. 18-D2, how is the existing interlocking system managed when altering an IB signal?

<p>The current status is transferred through the MSDAC. (A)</p> Signup and view all the answers

When considering Drg.No.17-D3 for applying cross bonding in track circuits where is the earth wire?

<p>Earth Wire,Single Line Track Circuits (A)</p> Signup and view all the answers

In the general context of railway signalling and with reference to typical wiring schemes, what is the key destination for wiring cables to ensure safety and proper equipment functioning?

<p>Earth (B)</p> Signup and view all the answers

According to Drg: No.15-D2, regarding the mixing ratio for casting foundations, what mixture should be used to follow standards?

<p>Cement, sand, and Jelly chips with the ratio of 1:3:6. (D)</p> Signup and view all the answers

Regarding Distributed EI and referring to related diagrams, where can detailed information about DC-DC panel converter allotments be found?

<p>Given as per site requirements. (A)</p> Signup and view all the answers

Before commencing interlocking projects, which aspect is most crucial to verify concerning planning and design?

<p>All dimensions in the interlocking plan. (D)</p> Signup and view all the answers

Which material is safest for bedding signal and telecommunication cables in trenches adjacent to tracks with respect to environmental impact or safety?

<p>Sand and soft soil. (C)</p> Signup and view all the answers

According to the preface, what primary factors guide the customization of drawings in the IRSEM Drawings Booklet?

<p>Site conditions, equipment type/size, Zonal Railways practices, and Railway Board/RDSO guidelines. (C)</p> Signup and view all the answers

Why is it important to refer to SEM chapters in conjunction with the IRSEM Drawings Booklet?

<p>To ensure that the drawings are interpreted and applied in accordance with relevant specifications and guidelines. (A)</p> Signup and view all the answers

What is the main purpose of including examples or drawings of particular equipment in Appendix II of IRSEM?

<p>To illustrate concepts and provide guidance/information to Signal Engineers &amp; Technicians. (D)</p> Signup and view all the answers

When high strength deformed steel bars are used for RCC duct construction, which Indian Standard (IS) code should they conform to, as per Drg.No.15-D3?

<p>IS:11786 (A)</p> Signup and view all the answers

What is the recommend Indian Standard (IS) code for Ordinary Portland Cement used in RCC duct construction, as per Drg.No.15-D3?

<p>IS:8112-1989 (C)</p> Signup and view all the answers

Refer to Drg.No.15-D5, What is being represented when a road crossing signaling tracks is depicted?

<p>Section AB for a road crossing signaling tracks (A)</p> Signup and view all the answers

What is required to do, regarding welding on a cable trough for a metallic bridge as outlined in Drg.No.15-D6

<p>No welding is allowed for fabrication on any component (C)</p> Signup and view all the answers

What specific action related to nuts is to be performed for cable trough installation on metallic bridges, according to Drg.No.15-D6?

<p>Burr the bolt thread after tightening. (B)</p> Signup and view all the answers

In a distributed EI system with 110VDC, what component directly provides power to the track circuits, as shown in Drg. No. 16-D1?

<p>DC-DC converters (A)</p> Signup and view all the answers

In a typical distributed Electronic Interlocking (EI) system, as per the details in Drg. No. 16-D1, what is the key function provided by the redundant power arrangement using 2Cx70Sqmm AC 230V cables?

<p>To provide a redundant path for IPS with path diversity for either side of the track (B)</p> Signup and view all the answers

Based on the general notes for coloring in power supply arrangement drawings, what does the green coloring signify?

<p>Identifies cable wire greater than 50 sq. mm (C)</p> Signup and view all the answers

According to Drg. No. 19-D5, what is the primary function of the equipment within the 'Inspection Chamber' related to earthing?

<p>Facilitating visual inspection of earth pit connections (A)</p> Signup and view all the answers

When altering an IB signal, according to Drg. No. 18-D2, how is the existing interlocking system handled?

<p>The status of signals are required between IB &amp; stations to be transferred through IBS (D)</p> Signup and view all the answers

When applying cross bonding in track circuits referencing to Drg.No.17-D3 where the Earth wire can be located?

<p>Run parallel to the track and bonded only in single-line circuits (B)</p> Signup and view all the answers

In the general scope of railway signalling and based on typical wiring schemes, within the context of railway signalling, what is a key and pivotal destination for wiring and cabling?

<p>Connected to Earth (A)</p> Signup and view all the answers

As per Drg: No.15 - D2, regarding the mixing ratio for casting foundations, what is the proper sand and Jelly mixing ratio and Cement content follow?

<p>1:3:6 (C)</p> Signup and view all the answers

With reference to Distributed EI and associated diagrams, where can detailed information on DC-DC panel converter allotments be found?

<p>As per Site Requirement (C)</p> Signup and view all the answers

Regarding interlocking, what factor is most important to verify before beginning any design or implementation work?

<p>Complete dimensions and layout have been checked (D)</p> Signup and view all the answers

Which material will be suitable for Burrying Adjacent to the Tracks in trenches with minimum depth with respect to environmental aspect or safe for the cable?

<p>Excavated soft soil (B)</p> Signup and view all the answers

Flashcards

IRSEM Appendix II

A document containing drawings for guidance, which can be customized for site conditions and equipment types. It also adheres to Railway Board/RDSO's drawings/schemes, reliability, availability, maintainability, safety, and industry's best practices.

IRSEM Drawing Numbering

Drawings are numbered as Drg no: Chapter Number-Drawing Number like 19-D3, where 19 represents the chapter and 3 represents the third drawing in the chapter.

RCC Cable Marker

A marker used to identify the location of underground cables, marked with 'IR SIG,' 'IR QUAD,' or 'IR OFC.' They are painted red with white lettering and placed at specific intervals.

Cable Laying in Rocky Areas

This is the method used for cable laying in areas with rock at a shallow depth (300 mm, 400 mm, or 600 mm). It involves creating a protective cement concrete layer above the cable.

Signup and view all the flashcards

RCC Duct

A structure which consists of trunking and capping that are suitable for burying adjacent to the tracks in trenches with a minimum depth of 600 mm.

Signup and view all the flashcards

DWC Split Pipe

A pipe sectioned lengthwise for easy installation and maintenance of cables.

Signup and view all the flashcards

Cable Core Plan

A diagram showing cable core usage for a specific railway station layout, including details of cable types, core assignments, and equipment connections. It ensures organized and efficient cable management.

Signup and view all the flashcards

Mechanical Signalling Colour Codes

The coloring and markings applied to mechanical signalling gears, signal arms, point indicators, boards, and markers.

Signup and view all the flashcards

ELB at Station

The location of essential electrical equipment at a station.

Signup and view all the flashcards

EL Power Supply Arrangement

A system to provide a reliable and uninterrupted power supply to signaling equipment. These arrangements include redundancies to ensure fail-safe operation

Signup and view all the flashcards

Cross Bonding

A safety measure used in railway tracks involving the connection of rails to ensure electrical conductivity and reduce the risk of electrical hazards, particularly in electrified sections.

Signup and view all the flashcards

IB Hut Layout Plan

Layout in interlocking cabin designed to control railway signalling and interlocking systems, including the placement of various components and equipment.

Signup and view all the flashcards

Filter Unit for Block Circuits

A device used in railway signaling systems to filter out unwanted frequencies or electrical noise from block circuits.

Signup and view all the flashcards

Protective Devices

Safety features like surge protection devices that protect equipment from high-voltage surges in AC electrified areas (Neale's type).

Signup and view all the flashcards

Outdoor Signalling

Arrangements related to installing, testing, and maintaining outdoor signaling equipment, including aspects like foundation requirements.

Signup and view all the flashcards

Apparatus Case Full Size Foundation

A foundation that provides full support and stability for apparatus cases used in railway signaling installations.

Signup and view all the flashcards

Signal Post Foundation

Details for building foundations specialized for signal posts.

Signup and view all the flashcards

Full Location Wiring Format

Format for documenting wiring connections at a signal location, aiding technicians in maintenance and troubleshooting.

Signup and view all the flashcards

Signal Markers & Number Plates

Plates or signs that mark and identify railway signals and other signalling equipment, including their unique numbers or identifiers.

Signup and view all the flashcards

Automatic Block Signalling

A signaling system that automatically controls train movements between stations, improving efficiency and safety. This system typically includes track circuits, signals, and control equipment.

Signup and view all the flashcards

Relay & Electronic Interlocking

Planning considerations for constructing buildings that house relay and electronic equipment, including layouts and arrangements.

Signup and view all the flashcards

ASM Room Layout Plan

A layout plan detailing the arrangement of equipment and facilities inside an ASM (Assistant Station Manager) room.

Signup and view all the flashcards

Earthing Connections

Electrical connections that ensures electrical safety and proper equipment functioning, often according to standards like RDSO Drg.

Signup and view all the flashcards

Signal Clearance Diagram

Diagrams that show the necessary clearances around railway tracks to safely accommodate 25 KV AC traction systems.

Signup and view all the flashcards

Conversion Formulae

Formulas for converting between different units of measurement.

Signup and view all the flashcards

Study Notes

Indian Railways Signal Engineering Manual - Appendix II (Drawings for Guidance)

  • Published in June 2021 by the Indian Railways Institute of Signal Engineering and Telecommunications, Secunderabad.
  • Created for the Government of India, Ministry of Railways (Railway Board), New Delhi.
  • Contains drawings for guidance that can be customized based on site conditions and Zonal Railways practices.
  • Customization considers Railway Board/RDSO's Drawings/Schemes, Reliability, Availability, Maintainability, Safety, and Industry's Best Practices.
  • Drawings are numbered using a convention of Drg no: 19-D3, where 19 represents the Chapter Number and 3 the third drawing in the specific chapter.
  • Drawings should be read alongside relevant provisions in the concerned chapter of the Signal Engineering Manual (SEM).
  • Any example/drawing illustrating particular equipment or acronym usage is for guidance only for Signal Engineers & Technicians.
  • Examples/drawings do not endorse any specific make/brand/equipment.

Index of Drawings

  • Chapter 8: Details and Specifications
    • Drg no-8-D1 has the signalling Interlocking Plan for Double Line Stations (A2 Size)
    • Drg no-8-D2 gives a Control Table for Double Line Station (Sheets-4) with (A3 Size)
    • Drg no-8-D3 shows the VDU Layout Plan for Electronic Interlocking (EI) (A3 Size)
  • Chapter 12: Covers the Installation, Testing & Maintenance of Mechanical Signalling Equipment
    • Drg. No.12-D1 provides various mechanical Signalling Gears – Colouring Scheme (Sheets 6)
  • Chapter 15: Cables
    • Drg. No.15-D1 contains a drawing for RCC cable marker
    • Drg. No.15-D2 contains a drawing for cable laying when rock faced at 300 mm, 400 mm, 600 mm (Sheets 3)
    • Drg. No.15-D3 contains a drawing for RCC duct 500 mm (Sheet 1 of 2) & a drawing of RCC split pipe 100 mm dia. (Sheet 2 of 2)
    • Drg. No.15-D4 contains a drawing of DWC Split Pipe(120 mm dia.)
    • Drg. No.15-D5 contains a drawing for Road/Track crossing
    • Drg. No.15-D6 contains a drawing for Cable trough for metallic bridge
    • Drg. No.15-D7 contains a drawing for Cable laying on culverts
    • Drg. No.15-D8 contains a drawing for Cable laying on culverts with high flood level.
    • Drg. No.15-D9 contains a Cable core plans for 4-Road station with PI (Sheet 1 of 3) and for 6-Road station with Distributed El (Sheet 2 of 3) as well as for 6-Road station with Pl with either side cable Huts. (Sheet 3of 3) (A2 Size)
    • Drg. No.15-D10 contains Cable Plan for Electric Lifting Barrier(ELB) at the Station
  • Chapter 16: Power Supply systems for Signalling Installations
    • Drg No.16-D1 contains the Scheme of Power Supply Arrangement for Distributed El (Sheets-4)
    • Drg No.16-D2 contains the Power Supply Arrangement for Central EI (Sheets-4)
    • Drg No.16-D3 contains IPS Arrangement for Interlocked LC Gate & IBS (Sheets-2)
  • Chapter 17: Pertains to Train Detection - Track Circuits & Axle Counters
    • Drg No.17-D1 contains a drawing for Track Lead Cable Connections
    • Drg No.17-D2 contains a Track Circuit Bonding Diagram for Typical 4 Road Station (Double Line)(A3 Size)
    • Drg No.17-D3 contains data on Cross Bonding in Double Line and Single Line Track Circuits, Earth wire in Single Line
  • Chapter 18: Block Instruments, BPAC & IBS Working
    • Drg No. 18-D1 displays an IB Hut Layout Plan (Double Line/Single Line)
    • Drg No. 18-D2 shows IB Signalling with MSDAC & OFC (Double Line) (Sheets-2)
    • Drg No. 18-D3 : IB Signalling with MSDAC & OFC (Single Line) (Sheets-2)
    • Drg No. 18-D4 : Filter Unit for Block Circuits
    • Drg No. 18-D5: Protective Devices for AC Electrified Area of Neales 'A' Type Token Instrument- Earth Return
    • Drg No. 18-D6: Protective Devices for AC Electrified Area of Neales 'A' Type Token Instrument - Metallic Return
    • Drg No. 18-D7 contains Double Line Block Working with Protective Device for AC Electrified Area
  • Chapter 19: Outdoor Signalling - Installation, Testing and Maintenance of Equipment
    • Drg No.19-D1 : Apparatus Case Full-Size Foundation
    • Drg No.19-D2 : Apparatus Case Half/Quarter Size Foundation
    • Drg No.19-D3 : Main Signal Post Foundation (Sheets-2)
    • Drg No.19-D4 : Shunt Signal Foundation
    • Drg No.19-D5 : Drawing of Earthing for S&T Installation
    • Drg No.19-D6 : Earthing Arrangement for Signals, Location Boxes
    • Drg No.19-D7 : Copper Plate Earthing Arrangement
    • Drg No.19-D8 : Full Location Wiring Format
    • Drg No.19-D9 : Half Location Wiring Format
    • Drg No.19-D10 : Signal Markers & Number Plates (Sheets-10)
  • Chapter 20: Automatic Block Signalling
    • Drg No 20-D1 : Automatic Signalling Scheme With OFC, MSDAC & OC (sheets-3)
  • Chapter 21: Relay & Electronic Interlocking
    • Drg No.21-D1 : S&T Building Plan up to 4 Road Stations
    • Drg No 21-D2 : S&T Building Plan for 5 to 8 Road Stations
    • Drg No 21-D3 : S&T Building Plan for End Goomties (EI)
    • Drg No 21-D4 : ASM Room Layout Plan.
    • Drg No 21-D5 : SM Table with Dual VDUs
    • Drg No 21-D6 : Contact Configuration (8F/8B) & (12F/4B)
    • Drg No 21-D7 : Contact Analysis Format (8F/8B), Contact Analysis with Posting of Contacts (12F/4B) (Sheets-2)
    • Drg no-21-D8 : Bonding & Earthing Connections for Signalling Equipments (RDSO Drg)
  • Chapter 22: Requirements of Signalling in 25 KV AC Electrified Area
    • Drg no-22-D1 : Signal Clearance Diagram to Suit 25 KV AC Traction for Tangent Tracks and Curved Tracks with S.E.60
    • Drg no-22-D2 : Signal Clearance Diagram to Suit 25 KV AC Traction for Curved Tracks with 60 to 140 S.E.
    • Drg no-22-D3 : Signal Clearance Diagram to Suit 25 KV AC Traction for Curved Tracks with 140 to 185 S.E.
    • Drg no-22-D4 : Colour Light Signal Left Hand or Right Hand Broad Gauge (Tangent Track)
    • Drg no-22-D5 : Colour Light Signal With Junction Route Indicator Left Hand or Right Hand Broad Gauge (Tangent Track)
    • Drg no-22-D6 : Distance in Rear from the Signal in Meters (Sheets-2)
    • Drg no-22-D7 : Distance in Rear from the Signal in Meters (For High Rise OHE) (Sheets-2)
    • Drg no-22-D8 : Implantation of OHE Structures With Respect to Colour Light Signal
    • Drg no-22-D9 : Signalling Feed Arrangement With Cut-In Relays
    • Conversion Formulae
    • Installation Photographs

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

Related Documents

More Like This

Railway Signal Types
14 questions

Railway Signal Types

FineProbability avatar
FineProbability
 Railway Signal and Telecommunication Chapter 18
40 questions
Use Quizgecko on...