35 Questions
What is the primary tactical priority for first alarm companies when dealing with a fire in a garage?
Preventing fire extension into the residence
What action should be prioritized when the officer determines that the fire has extended into the home during the size up process?
Stretching an additional line to extinguish the garage from the exterior
Under what circumstances may entry be approved by the IC if the garage has been converted to living quarters and interior walls are present?
If the structural members are protected and not involved with fire
What is the best way to hold fire in check while crews search for the seat of fire in these big box stores?
Using standpipe systems
What is the primary concern when dealing with smoke conditions in big box stores?
Cold smoke giving a false impression of the fire's extent
What is a characteristic feature of roof construction in big box stores that makes it difficult for firefighters to locate support members?
Spray foam insulation
What type of construction is typically used for the walls of big box stores?
Concrete tilt-up
What is the primary function of a RIC crew in a big box store fire?
Maintain accountability of interior crews
What is the primary purpose of the 360 procedure during an incident?
To gather information on fire and smoke conditions
Which action is a part of the Incident Stabilization Priority?
Treating the injured and providing for safety of response personnel
What is the primary concern when dealing with post-incident control procedures?
Ensuring proper evaluation of risk
What is the main purpose of establishing an Incident Command Post (ICP)?
To centralize decision-making and coordination of resources
What is the primary responsibility of the first in officer during a fire incident?
Conducting a size-up using relevant elements and requesting additional alarms if smoke is visible
What is a common hazard associated with center hall construction in commercial occupancies?
Rapid fire and smoke spread due to open interior stairways
What is the best way to hold fire in check while crews search for the seat of fire in a building with center hall construction?
Assigning unit to support sprinkler system depending on strategy declared
What type of construction involves exterior masonry load-bearing walls and wood joist floors and roofs?
Type III Construction
In a building with multiple occupancies, where is the main entrance usually accessed from?
Common hallway
What type of construction has walls and roofs made of combustible materials, most commonly wood?
Type V Construction
In a 'U' shaped building like Sunnyside Glenn, where is the main entrance accessed from?
Common hallway
What is the purpose of the policy outlined in the SOP manual for tactical operations in buildings with center hall construction?
To establish a standard method for FFD members to combat fires in center hall constructed buildings
What is the significance of utilizing additional alarms if smoke is showing, as per the operational guideline?
To consider the possibility of a large scale fire outbreak
What is the primary role of the first-in officer in combatting fires in buildings with center hall construction?
Organizing the overall incident
What is the main priority for first alarm companies when dealing with a fire in a garage?
Identifying the location of the fire through the roof type and construction
What is a characteristic feature of roof construction in big box stores that makes it difficult for firefighters to locate support members?
The use of lightweight materials for the roof
Under what circumstances may entry be approved by the Incident Commander (IC) if the garage has been converted to living quarters and interior walls are present?
Based on the survivability profile of the individuals inside
What is the purpose of the Personnel Accountability System?
To provide accurate member accountability at emergency scenes
When are the red passports brought to the Incident Command Post?
After receiving a tactical assignment
What is the responsibility of the CO regarding passports when units or personnel are released from an incident?
The CO is responsible for retrieving both the black and red passports before leaving the incident
What is the recommended duration for hand washing with soap and warm water?
10 to 15 seconds
When should mouth-to-mouth resuscitation be performed according to the guidelines?
Only when bag-valve mask is not available
What should be worn by members performing wash-down tasks on public property?
Gloves, eye protection, and a face mask or particulate respirator
What is the purpose of Receptacle Circuit Testers used by Fire Companies?
To verify the correct wiring of standard three-pronged electrical receptacles
What do the red, white, and yellow lenses on the Receptacle Circuit Tester indicate?
The usability of the electrical receptacle
What is the purpose of Receptacle Circuit Testers used by Fire Companies?
To verify the correct wiring of three-pronged electrical receptacles
What should be considered when plugging a Receptacle Circuit Tester into an outlet?
The presence of a proper ground in the outlet
This manual provides information on the proper use and application of receptacle circuit testers by Fire Companies to verify the correct wiring of standard 'U' ground electrical receptacles. The manual includes details on the effective date, author, next revision date, purpose, and application of the policy.
Make Your Own Quizzes and Flashcards
Convert your notes into interactive study material.
Get started for free