Which characteristic distinguishes thermocouple extension wire from regular thermocouple-grade wire?
Which characteristic distinguishes thermocouple extension wire from regular thermocouple-grade wire?
- Insulation color
- Thickness
- Special markings on wire’s insulation
- Outer sheath color (correct)
What type of dynamic fluid effect is illustrated by a flag flapping in the breeze?
What type of dynamic fluid effect is illustrated by a flag flapping in the breeze?
- Transitional flow
- Coriolis effect
- Vortex shedding (correct)
- Inertial effects
What flow condition is necessary for accurate operation of orifice plate flow meters?
What flow condition is necessary for accurate operation of orifice plate flow meters?
- Turbulent flow
- Fully-developed turbulent flow (correct)
- Transitional flow
- Plug flow
What does Cascade control involve?
What does Cascade control involve?
What type of signal is associated with a mechanical input to an electronic transmitter?
What type of signal is associated with a mechanical input to an electronic transmitter?
Where should one look to understand the meaning of a symbol on a P&ID?
Where should one look to understand the meaning of a symbol on a P&ID?
What condition describes Quarter-wave damping in control systems?
What condition describes Quarter-wave damping in control systems?
What happens to an incompressible fluid as it moves through a restriction?
What happens to an incompressible fluid as it moves through a restriction?
Which temperature sensing element is considered the most linear?
Which temperature sensing element is considered the most linear?
What metals are used to construct a type K thermocouple?
What metals are used to construct a type K thermocouple?
When converting a level measurement system from a dry leg to a wet leg, which calibration aspect must be changed?
When converting a level measurement system from a dry leg to a wet leg, which calibration aspect must be changed?
Under what condition are flow-straightening vanes necessary for orifice plates?
Under what condition are flow-straightening vanes necessary for orifice plates?
What condition could result in pressure gauge A showing a higher reading than pressure gauge B in a liquid process?
What condition could result in pressure gauge A showing a higher reading than pressure gauge B in a liquid process?
Which level measurement technology is least likely to maintain accuracy with changing liquid density?
Which level measurement technology is least likely to maintain accuracy with changing liquid density?
What is the primary purpose of performing an 'As Found' calibration on a pressure transmitter?
What is the primary purpose of performing an 'As Found' calibration on a pressure transmitter?
Which of the following is NOT a typical method for measuring pH in a process?
Which of the following is NOT a typical method for measuring pH in a process?
What is the primary purpose of a control valve positioner?
What is the primary purpose of a control valve positioner?
How does an alkaline solution typically rank in pH value?
How does an alkaline solution typically rank in pH value?
In a process with constant differential pressure, which valve characteristic is most suitable?
In a process with constant differential pressure, which valve characteristic is most suitable?
What should be verified before connecting an ohmmeter to a circuit?
What should be verified before connecting an ohmmeter to a circuit?
Given a drop in pressure of 19 PSID, what is the necessary Cv rating for a control valve at a maximum flow rate of 250 GPM?
Given a drop in pressure of 19 PSID, what is the necessary Cv rating for a control valve at a maximum flow rate of 250 GPM?
When classifying control valves, which of the following order represents the types in a typical setup?
When classifying control valves, which of the following order represents the types in a typical setup?
In calculating Cv rating for a liquid service control valve, which factors must be considered?
In calculating Cv rating for a liquid service control valve, which factors must be considered?
What is a common unit for expressing reset control action?
What is a common unit for expressing reset control action?
Flashcards
Linear Temperature Sensing Element
Linear Temperature Sensing Element
A temperature sensor whose output changes proportionally to the temperature. A device that responds linearly to change in temperature.
Type K Thermocouple Metals
Type K Thermocouple Metals
A type of thermocouple composed of Chromel and Alumel metals.
Wet Leg Level Measurement System Calibration Change
Wet Leg Level Measurement System Calibration Change
When a level measurement system is changed from a dry leg to a wet leg, the transmitter's zero calibration needs adjustment.
Flow-Straightening Vanes Use
Flow-Straightening Vanes Use
Signup and view all the flashcards
Unequal Pressure Gauge Readings
Unequal Pressure Gauge Readings
Signup and view all the flashcards
Accurate Liquid Level Measurement with Variable Density
Accurate Liquid Level Measurement with Variable Density
Signup and view all the flashcards
"As Found" Calibration Purpose
"As Found" Calibration Purpose
Signup and view all the flashcards
Thermocouple extension wire
Thermocouple extension wire
Signup and view all the flashcards
Vortex shedding
Vortex shedding
Signup and view all the flashcards
Orifice plate flow meter
Orifice plate flow meter
Signup and view all the flashcards
Cascade control
Cascade control
Signup and view all the flashcards
Electronic transmitter input signal
Electronic transmitter input signal
Signup and view all the flashcards
P&ID symbol meaning
P&ID symbol meaning
Signup and view all the flashcards
Quarter-wave damping
Quarter-wave damping
Signup and view all the flashcards
Incompressible fluid restriction
Incompressible fluid restriction
Signup and view all the flashcards
Air-to-close control valve
Air-to-close control valve
Signup and view all the flashcards
Fuel gauge sending unit (bimetallic)
Fuel gauge sending unit (bimetallic)
Signup and view all the flashcards
IVR Voltage Regulation
IVR Voltage Regulation
Signup and view all the flashcards
Reset Control Action Units
Reset Control Action Units
Signup and view all the flashcards
Integrating Processes & Aggressive Control
Integrating Processes & Aggressive Control
Signup and view all the flashcards
Choker Hitch Sling Length (24 inch pipe)
Choker Hitch Sling Length (24 inch pipe)
Signup and view all the flashcards
Ohmmeter Connection Procedure
Ohmmeter Connection Procedure
Signup and view all the flashcards
Alkaline Solution pH
Alkaline Solution pH
Signup and view all the flashcards
Control Valve Cv Rating Calculation
Control Valve Cv Rating Calculation
Signup and view all the flashcards
Control Valve Trim for Constant Differential Pressure
Control Valve Trim for Constant Differential Pressure
Signup and view all the flashcards
Control Valve Types (Left-to-Right)
Control Valve Types (Left-to-Right)
Signup and view all the flashcards
Air-to-Close Actuator/Valve Combinations
Air-to-Close Actuator/Valve Combinations
Signup and view all the flashcards
Control Valve Positioner Purpose
Control Valve Positioner Purpose
Signup and view all the flashcards
Study Notes
I&C Technician Sample Questions & Answers
-
Question 1: The most linear temperature sensing element is an RTD.
-
Question 2: A type K thermocouple is made from Chromel and Alumel.
-
Question 3: If a level measurement system changes from a dry leg to a wet leg, the transmitter's zero needs to be changed.
-
Question 4: Flow-straightening vanes are used upstream of orifice plate flow elements when insufficient straight-pipe length exists, or when the process fluid is a gas.
-
Question 5: A high rate of flow from left to right (top to bottom) in a liquid process could cause pressure gauge A to register a greater pressure than pressure gauge B.
-
Question 6: A differential pressure transmitter will not maintain accurate liquid height measurement in a vessel with unpredictable density changes.
-
Question 7: The purpose of an “As Found” calibration on a pressure transmitter is to establish a baseline for comparison to detect calibration drift.
-
Question 8: The LRV for the given DP-based liquid level measurement system is 84 "H2O and URV is 444 "H2O.
-
Question 9: A load cell cannot be adapted to measure solid (powder) levels in a vessel.
-
Question 10: A guided-wave radar transmitter measures liquid interface levels based on differences in the dielectric constant between the two liquids.
-
Question 11: The hydrostatic pressure at the bottom of a vessel holding 12 vertical feet of liquid with a density of 50 lb/ft3 is 14.98 PSI.
-
Question 12: The negative lead of a thermocouple in North America is colored black.
-
Question 13: Reference junction compensation is necessary in thermocouple-based temperature instruments because the reference junction generates a temperature-dependent voltage.
-
Question 14: Thermocouple extension wire can be distinguished from regular thermocouple wire by its outer sheath color.
-
Question 15: As an incompressible fluid moves through a restriction, velocity increases and pressure decreases.
-
Question 16: For accurate orifice plate flow meters, fully-developed turbulent flow is required.
-
Question 17: Based on the relative position of the transmitter and orifice plate, this flow measuring installation is suitable for gas flow.
-
Question 18: If the flow measurement range is decreased to 0 to 700 GPH, the new calibration range for the DP transmitter is 0 to 34.03 "H2O.
-
Question 19: A thermal flowmeter inherently measures mass flow rate.
-
Question 20: The pH of a liquid solution is a measure of hydrogen ion activity
-
Question 21: Flue gas oxygen measurement is important in combustion control systems for reducing NOx emissions.
-
Question 22: A chromatograph separates molecule types in a fluid stream by adsorption time-delay.
-
Question 23: ORP measurement is often used where the addition of an oxidant must be controlled.
-
Question 24: A varying voltage is an analog signal.
-
Question 25: Computers rely on sensors for input signals.
-
Question 26: A suppressed zero in a DP cell means the transmitter is located below the 0% liquid level mark.
-
Question 27: The height of the building and flow rate must be determined prior to selecting a hydronic circulator.
-
Question 28: The minimum wall thickness of pipe for a hydraulic system is Schedule 40 pipe.
-
Question 29: Fluid power actuators convert fluid to motion.
-
Question 30: A buffer solution is used to calibrate pH probes.
-
Question 31: A flue gas oxygen measurement is important to reduce NOx emissions in combustion control systems.
-
Question 32: Feedforward control reduces the effect of process variable noise on stability.
-
Question 33: In PLC programming, a retentive function defaults to the "off" state and is not reset after a power cycle.
-
Question 34: When noise is present and offset isn't acceptable in a control application, PID control is used.
-
Question 35: Voltage between terminals 15 and 16 depends on flow rate.
-
Question 36: A load disturbance is a deviation from set point due to load variation.
-
Question 37: The correct ring type joint RTJ gasket for a hydraulic line is type D (crush ring).
-
Question 38: Integer variables in a digital control system are used to represent the status of single switches or count discrete events.
-
Question 39: The statement that the standard analog signal 4-20 mA is the most common and used in the process control industry today is true.
-
Question 40: To get the best pumping rate from a two-pipe convertible deep well jet system, open the pump discharge control valve fully.
-
Question 41: Digital control systems are generally superior to analog systems but are less user friendly.
-
Question 42: A triple modular redundant (TMR) digital control system is used to control a dangerous process.
-
Question 43: A symbol of a pneumatic valve is a combination of a cross and a circle (like the letter 'D').
-
Question 44: PPE stands for Personal Protective Equipment.
-
Question 45: Increasing spring tension on a valve causes it to open more quickly.
-
Question 46-48: Instructions and descriptions for the related instruments.
-
Question 49: In an instrument needing calibration, the zero adjustment is usually done first.
-
Question 50: A pressure switch activates the motor of an instrument air compressor.
-
Question 51: The calculated fluid pressure working against the piston, given a force and piston diameter, is 1082.3 PSI.
-
Question 52: The proper sequence for taking a differential pressure transmitter out of service, using a three-valve manifold and bleed, is closing one block valve and opening the equalizing valve and then opening the bleed.
-
Question 53: The warning lamp of a charging system is activated by a difference in voltage.
-
Question 54: A maximum pressure relief valve is typically mounted on the tank.
-
Question 55-70: Instructions and descriptions related to various parameters.
-
Question 71-84: Instructions related to various instruments and their purposes.