Hydrogen Compressor Emergency Procedures

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the first step to take if the Hydrogen Compressor is lost?

  • Unload make-up and recycle cylinders on the Hydrogen Compressor (13C-101/102). (correct)
  • Monitor temperatures in the Reactors (13PV-2301/2302).
  • Restart the Hydrogen Compressor (13C-101/102) as soon as possible.
  • Reload make-up and recycle cylinders on the Hydrogen Compressor (13C-101/102), as needed.

What should be done if Fin Fans trip off during a power blip?

  • Unload make-up and recycle cylinders on the Hydrogen Compressor (13C-101/102).
  • Monitor temperatures in the Reactors (13PV-2301/2302).
  • Reload make-up and recycle cylinders on the Hydrogen Compressor (13C-101/102), as needed.
  • Check and restart the Fin Fans. (correct)

What is the role of the control system after the power blip?

  • To monitor temperatures in the Reactors (13PV-2301/2302).
  • To determine the Unit conditions and decide whether to bring the Unit back online or call for re-introduction of feeds. (correct)
  • To restart the Hydrogen Compressor (13C-101/102) as soon as possible.
  • To unload make-up and recycle cylinders on the Hydrogen Compressor (13C-101/102).

What is the purpose of monitoring the temperatures in the Reactors (13PV-2301/2302)?

<p>To ensure the safe operation of the Reactors during re-introduction of feeds. (A)</p> Signup and view all the answers

Which of these is NOT a step in the Immediate Emergency Actions section?

<p>Replacing damaged parts immediately after a power blip. (D)</p> Signup and view all the answers

Which type of pump is NOT listed as critical equipment to check after a power loss?

<p>Feed Water Pump (D)</p> Signup and view all the answers

What is the first step to take when a momentary power loss occurs?

<p>Assess the condition of the unit (C)</p> Signup and view all the answers

What type of pumps are 13P-101/102?

<p>Feed Charge Pumps (A)</p> Signup and view all the answers

What is the primary focus after a power loss?

<p>Ensuring critical equipment is functional (B)</p> Signup and view all the answers

If the Feed Charge Pumps malfunctioned during a power outage, what action should be taken?

<p>Attempt to restart them in the same configuration (B)</p> Signup and view all the answers

Flashcards

Power Loss Response

Assessment of unit condition after power interruption, focusing on critical pumps and condensers.

Critical Equipment

Key pumps to check after a power loss, including hydrogen compressors and condensate pumps.

Electrical Pump Check

Procedure to inspect and restart electrically driven pumps after a power loss.

Feed Charge Pump Recovery

Restarting Feed Charge Pumps in original configuration after power disruption.

Signup and view all the flashcards

Pump Restart Procedure

Steps to take for all pumps that failed due to electrical issues during power loss.

Signup and view all the flashcards

Fin Fans

Fans that help cool equipment during operations.

Signup and view all the flashcards

Restart Hydrogen Compressor

The action of turning the Hydrogen Compressor back on after a shutdown.

Signup and view all the flashcards

Monitor Reactor Temperatures

Keep track of the heat levels within Reactors 13PV-2301/2302.

Signup and view all the flashcards

Make-up and Recycle Cylinders

Cylinders used for supplying and recycling hydrogen in the system.

Signup and view all the flashcards

Unit Conditions Assessment

Evaluate the state of the unit to determine its operational status.

Signup and view all the flashcards

More Like This

Hydrogen Oxygen Fuel Cells Quiz
3 questions

Hydrogen Oxygen Fuel Cells Quiz

ComplementaryWilliamsite avatar
ComplementaryWilliamsite
Chemistry Quiz: Hydrogen Bonds
5 questions
Hydrogen Compression System in HDS Unit #3
36 questions
Use Quizgecko on...
Browser
Browser