Hot Work Outlines and Requirements in Tasnee
155 Questions
2 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is required before entering a Confined Space under Category A?

  • Review the Incident Commander's Rescue plan
  • Prepare a Rescue plan countersigned by the permit issuer (correct)
  • Obtain approval from the Incident Commander
  • Attach the Rescue plan to the confined space entry permit at the site

What should be done with open manways or covers not in use in a Confined Space?

  • They should be sealed with cement
  • They should be positively barricaded (correct)
  • They should be left open for easy access
  • They should be barricaded with tape

What is a requirement for safe access and exit in a Confined Space?

  • Having personnel underneath when lowering or removing material
  • Using a cage for lifting material without it being part of the JSA
  • Having personnel lowered without facilities to climb back out
  • Providing adequate and safe access and exit out (correct)

What happens if condition changes during a Confined Space Entry Permit?

<p>A new Rescue plan needs to be prepared and approved (D)</p> Signup and view all the answers

Who should approve the Rescue plan for Confined Space Entry under Category A?

<p>Incident Commander (D)</p> Signup and view all the answers

What should not be used to barricade manways or covers in a Confined Space?

<p>Tape (D)</p> Signup and view all the answers

Why should personnel not be lowered into Confined Spaces without facilities to climb back out?

<p>To avoid potential entrapment hazards (A)</p> Signup and view all the answers

What equipment should be included in the JSA if lifting material/person using a cage within a Confined Space?

<p>Cage for lifting material/person (C)</p> Signup and view all the answers

What is the purpose of venting in industrial operations?

<p>To release gases or vapors to the atmosphere during depressurization or purging (C)</p> Signup and view all the answers

How is ventilation achieved in an industrial setting?

<p>By drawing fresh air through a vessel using air moving devices or naturally (D)</p> Signup and view all the answers

What characterizes an oxygen-deficient atmosphere?

<p>Poses risks due to low oxygen levels (B)</p> Signup and view all the answers

What does the Lower Explosive Limit (LEL) refer to?

<p>Volume percentage of vapor in air below which flame propagation will not occur (A)</p> Signup and view all the answers

Who is a Gas Tester as defined in the text?

<p>An individual authorized to conduct gas tests using specialized equipment (C)</p> Signup and view all the answers

What is the Threshold Limit Value (TLV) related to?

<p>Safe concentration of toxic gases during extended work periods (B)</p> Signup and view all the answers

How is an Upper Explosive Limit (UEL) characterized?

<p>Maximum concentration of a flammable gas in air that supports combustion (C)</p> Signup and view all the answers

What distinguishes a Breathing Apparatus as described in the text?

<p>Air supplied apparatus for breathing purposes, self-contained or recycled system (A)</p> Signup and view all the answers

When should a fresh gas test be carried out according to the text?

<p>Every 2 hours (C)</p> Signup and view all the answers

What should be done before restarting hot work after an interruption of more than one hour?

<p>Carry out a fresh gas test (C)</p> Signup and view all the answers

What is required to work in an atmosphere containing toxic gas or vapor according to the text?

<p>Appropriate protection as per Threshold Limit Value (TLV) (D)</p> Signup and view all the answers

What type of activities are considered 'hot work'?

<p>All of the above (D)</p> Signup and view all the answers

Who is responsible for maintenance and calibration of portable gas detector instruments?

<p>Maintenance or authorized third party (A)</p> Signup and view all the answers

What is a requirement for running/operating equipment at a site?

<p>Hot work permit (B)</p> Signup and view all the answers

What should be done if there are fault indications noted by the operator using the gas detector?

<p>Report it immediately to the Operation Shift Supervisor (B)</p> Signup and view all the answers

Which method is NOT an acceptable way to achieve positive isolation for hot work?

<p>Using double block and bleed arrangements (A)</p> Signup and view all the answers

Where can the Threshold Limit Value (TLV) for each substance be found according to the text?

<p>In Safety Data Sheets (SDS) (A)</p> Signup and view all the answers

What should be ensured before starting hot work on an asset?

<p>No combustible materials remaining in the asset (A)</p> Signup and view all the answers

Under what conditions should gas testing be conducted or repeated?

<p>If there's doubt or requested, and in specific situations mentioned in the text (B)</p> Signup and view all the answers

What is a prohibited activity for hot work?

<p>Using cameras that produce internal sparks (B)</p> Signup and view all the answers

When should a hot work permit be obtained at a site?

<p>When exceeding the duration of a vehicle/equipment entry permit (C)</p> Signup and view all the answers

What is considered a hazard or high risk in the context of hot work?

<p>Presence of flammable materials (A)</p> Signup and view all the answers

'JSA' mentioned in the text refers to what?

<p>Job Safety Analysis (A)</p> Signup and view all the answers

What is a recommended method to minimize hazards when de-energization of underground utilities is not possible?

<p>Insulating workers and equipment from possible electrical contact (A)</p> Signup and view all the answers

In what scenario is a plan required for excavations?

<p>When excavating near structures or equipment (B)</p> Signup and view all the answers

What action should be taken if the excavation will obstruct a roadway or access?

<p>Notify the Security and Fire Sections (A)</p> Signup and view all the answers

Why should forklifts never be used to lift a person according to the text?

<p>To avoid workplace injuries (C)</p> Signup and view all the answers

What is the purpose of using barricades around the work area according to the text?

<p>To restrict access to unauthorized personnel (B)</p> Signup and view all the answers

Which precaution should be taken regarding lifting operations from the given text?

<p>Only allow experienced personnel to operate lifting equipment (B)</p> Signup and view all the answers

What is a crucial step to be completed before a work permit is issued, according to the text?

<p>Isolate energy sources and the process from the equipment (C)</p> Signup and view all the answers

In what way should tags be displayed on equipment to be worked on?

<p>In a clearly visible position (D)</p> Signup and view all the answers

Why is it prohibited to display a general tag on equipment for work to be performed?

<p>To avoid confusion about the safety status of the equipment (B)</p> Signup and view all the answers

What is necessary regarding tagging equipment for safe working conditions?

<p>Place tags visibly with all required information (A)</p> Signup and view all the answers

Why is it important to isolate energy sources before issuing a work permit?

<p>To prevent accidents and ensure safety (D)</p> Signup and view all the answers

What should be completed by the issuer before issuing a work permit?

<p>Identify potential hazards and take precautionary actions to control them (C)</p> Signup and view all the answers

What type of equipment is NOT allowed to ventilate confined spaces according to the text?

<p>Nitrogen (A)</p> Signup and view all the answers

What is the alternative ventilation equipment that should be kept ready in case of Air Conditioners shutdown according to the text?

<p>Air Movers (B)</p> Signup and view all the answers

What should be established and operated continuously during work in a confined space to ensure proper ventilation?

<p>Positive means of ventilation (C)</p> Signup and view all the answers

What is the document under which a ventilation plan should be prepared and approved according to the text?

<p>IMRS 13-02-01-23 Ventilation plan (C)</p> Signup and view all the answers

Which factor will determine the required ventilation rate when using Air Conditioners for ventilation in a confined space?

<p>Capacity of Air Conditioners (B)</p> Signup and view all the answers

What should be ensured about fans and air movers when using them to ventilate confined spaces according to the text?

<p>Electrically bonded and grounded to the vessel (A)</p> Signup and view all the answers

What are the three aspects mentioned in the text that should be considered for effective ventilation?

<p>Positioning of mechanical aspirators, drawing of fresh air, routing of exhaust air (C)</p> Signup and view all the answers

What must be established and operational throughout work in a confined space to maintain proper ventilation according to the text?

<p>'Positive means of ventilating confined space' (C)</p> Signup and view all the answers

What is the maximum allowable frequency between gas tests?

<p>2 hours (D)</p> Signup and view all the answers

What should workers do when a gas detector alarm sounds?

<p>Stop work, evacuate to a safe assembly area, and report to the permit issuer (B)</p> Signup and view all the answers

What is a mandatory requirement for open flame or spark conditions?

<p>Continuous gas testing (D)</p> Signup and view all the answers

What should be equipped on portable or continuous monitoring devices for warning purposes?

<p>An audible alarm and visible light (C)</p> Signup and view all the answers

What must happen for the alarms of the gas testing device to stop according to the text?

<p>Concentrations return to safe levels (B)</p> Signup and view all the answers

What is required to be recorded in the Work Permit by the authorized gas tester?

<p>The test result (C)</p> Signup and view all the answers

When should functional tests be carried out for the Gas detector device according to the text?

<p>During start of the operation each new shift (C)</p> Signup and view all the answers

What should workers ensure about good air near openings in enclosed locations?

<p>It does not ensure good air at the bottom (D)</p> Signup and view all the answers

Why is a Manway of 24 inches or less in the smallest dimension considered restricted?

<p>It does not allow normal spinal immobilization of an injured worker. (B)</p> Signup and view all the answers

What is one challenge rescuers may face when the Manway is located vertically in a confined space?

<p>The rescue may be delayed due to the difficulty in climbing down or up the permit space. (B)</p> Signup and view all the answers

What is the significance of having a developed Rescue plan for confined space entry during the job planning phase?

<p>It details how to escape and rescue personnel working in confined spaces. (A)</p> Signup and view all the answers

What method should be used to identify underground cables or utilities if de-energization is not possible or location is unknown?

<p>Use cable detector (D)</p> Signup and view all the answers

Why is it essential to know whether a confined space has a horizontal or vertical Manway access?

<p>To ascertain if rescuers must climb down or up the permit space respectively. (B)</p> Signup and view all the answers

When should the Security and Fire Sections be notified according to the text?

<p>When excavation will obstruct a roadway (B)</p> Signup and view all the answers

What is a key reason for using tools or equipment that reduce the possibility of damage to underground services?

<p>To avoid hazards to workers and services (C)</p> Signup and view all the answers

What is one drawback of a confined space with an elevated entrance located more than 4 feet above ground?

<p>Rescue teams might find it challenging to normally transport an injured worker. (A)</p> Signup and view all the answers

Why should forklifts never be used to lift a person as per the text?

<p>Safety concerns related to lifting personnel (C)</p> Signup and view all the answers

Why are manways of greater than 24 inches in the smallest dimension preferred?

<p>They allow relatively free movement into and out of the confined space. (B)</p> Signup and view all the answers

Why might a confined space with a horizontal Manway access present challenges during retrieval operations?

<p>Rescuers might have difficulty using retrieval lines. (C)</p> Signup and view all the answers

In what scenario should a plan be provided by the requester and approved by the Safe Making Department?

<p>For excavations deeper than 1.2 meters (A)</p> Signup and view all the answers

Why is it crucial to have a Rescue plan developed before issuing a confined entry Permit?

<p>To detail the method of entry, exit, escape, and rescue in confined spaces. (A)</p> Signup and view all the answers

What is the primary purpose of putting up barricades around a work area according to the text?

<p>To restrict access to unauthorized personnel (B)</p> Signup and view all the answers

Why should nobody be allowed to walk or reach under a raised load based on the text?

<p>To avoid potential entrapment or injury (A)</p> Signup and view all the answers

What is an essential step to minimize hazards during excavation when de-energization of underground utilities is not feasible?

<p>Insulate workers from electric shocks (B)</p> Signup and view all the answers

Hot Tapping involves connecting equipment or piping by welding or drilling while the equipment is not in service.

<p>False (B)</p> Signup and view all the answers

A Safe Maker is a person who is designated on the permit by the Permit Issuer for safe making, and they do not need to be trained or certified.

<p>False (B)</p> Signup and view all the answers

Excavation Work can only be done using manual tools according to the text.

<p>False (B)</p> Signup and view all the answers

A Breathing Apparatus is not mentioned as a requirement in the text for specific tasks.

<p>True (A)</p> Signup and view all the answers

Cold Work involves working on live electrical circuits.

<p>False (B)</p> Signup and view all the answers

The Threshold Limit Value (TLV) is directly related to the Lower Explosive Limit (LEL) in the text.

<p>False (B)</p> Signup and view all the answers

First line break refers to the final closing of piping or process equipment according to the text.

<p>False (B)</p> Signup and view all the answers

Hot Work includes any work that does not create enough heat or sparks to ignite flammable materials.

<p>False (B)</p> Signup and view all the answers

Process Isolation is a method used to prevent a liquid or gas process stream from being conveyed past a confined space.

<p>False (B)</p> Signup and view all the answers

A confined space is characterized by having natural ventilation and being intended for continuous employee occupancy.

<p>False (B)</p> Signup and view all the answers

The action of entering a confined space is considered completed only when the person's entire body is inside the space.

<p>False (B)</p> Signup and view all the answers

An excavation more than 1.2 meters in depth is not classified as a confined space.

<p>False (B)</p> Signup and view all the answers

Confined spaces are categorized into category A only.

<p>False (B)</p> Signup and view all the answers

Continuous employee occupancy is intended for all types of confined spaces.

<p>False (B)</p> Signup and view all the answers

A confined space entry occurs when any part of a person's body crosses the outside limits of the confined space.

<p>True (A)</p> Signup and view all the answers

Manholes, pits, and ducts are not examples of confined spaces.

<p>False (B)</p> Signup and view all the answers

Before issuing a work permit, all process and non-process equipment must be made safe.

<p>True (A)</p> Signup and view all the answers

In the text, it is allowed to display a general tag on equipment for work to be performed.

<p>False (B)</p> Signup and view all the answers

As per the text, tags must be placed in an inconspicuous position on the equipment being worked on.

<p>False (B)</p> Signup and view all the answers

In the provided text, all required information such as equipment number, name, date, and signature of a safe maker must be written on the tag attached to the equipment.

<p>True (A)</p> Signup and view all the answers

It is acceptable to use any means suitable for the application to attach tags to equipment for work.

<p>True (A)</p> Signup and view all the answers

Isolating energy sources is not listed as a step to be completed before issuing a work permit in the text provided.

<p>False (B)</p> Signup and view all the answers

As per the text, putting up barricades around a work area before issuing a work permit is optional.

<p>False (B)</p> Signup and view all the answers

The text states that before issuing a work permit, it is essential to prepare the equipment itself for safe working on it.

<p>True (A)</p> Signup and view all the answers

Breathing Apparatus can include canisters, cartridge, and filter masks according to the text.

<p>False (B)</p> Signup and view all the answers

The Upper Explosive Limit (UEL) refers to the minimum concentration of a flammable gas in air below which propagation of flame will not occur.

<p>False (B)</p> Signup and view all the answers

Oxygen Deficient Atmosphere is defined as an atmosphere containing less than 21% oxygen at sea level.

<p>True (A)</p> Signup and view all the answers

A Gas Tester must be trained in using gas detecting equipment and authorized to conduct gas tests according to the text.

<p>True (A)</p> Signup and view all the answers

Threshold Limit Value (TLV) is the toxic gas concentration above which it is not safe to work for extended periods according to the text.

<p>False (B)</p> Signup and view all the answers

Venting involves releasing gases or vapors to the atmosphere during depressurization or purging activities.

<p>True (A)</p> Signup and view all the answers

Ventilation in an industrial setting can be achieved by using self-contained breathing apparatus (SCBA).

<p>False (B)</p> Signup and view all the answers

The Lower Explosion Limit (LEL) is expressed as a volume percentage of vapor in air according to the text.

<p>True (A)</p> Signup and view all the answers

Gas detectors are only accurate in atmospheres containing oxygen between 10% and 20.8%.

<p>False (B)</p> Signup and view all the answers

Gas testing is not required for confined space entry according to the text.

<p>False (B)</p> Signup and view all the answers

You can enter a hazardous atmosphere even if it has not been tested according to the text.

<p>False (B)</p> Signup and view all the answers

Gas testing is conducted to determine the required personal protective equipment.

<p>True (A)</p> Signup and view all the answers

A fresh gas test should be carried out every hour according to the text.

<p>False (B)</p> Signup and view all the answers

Gas detectors should be used in atmospheres containing oxygen above 20.8% for accurate readings.

<p>False (B)</p> Signup and view all the answers

Gas testing is a requirement for working in live electrical circuits according to the text.

<p>True (A)</p> Signup and view all the answers

Gas detectors should not be used in atmospheres with oxygen below 10% for accurate readings.

<p>True (A)</p> Signup and view all the answers

If hazard can be mitigated, then Rescue shall be prepared prior to entry.

<p>False (B)</p> Signup and view all the answers

A baffle or mixing blade in a confined space would not be considered an obstruction for rescue purposes.

<p>False (B)</p> Signup and view all the answers

Elevated confined spaces usually require low angle rescue procedures.

<p>False (B)</p> Signup and view all the answers

Conducting a fresh gas test before issuing a work permit is not necessary according to the text.

<p>False (B)</p> Signup and view all the answers

Continuous employee occupancy is required for all types of confined spaces.

<p>False (B)</p> Signup and view all the answers

Hot work permits should not be obtained at a site for safety reasons.

<p>False (B)</p> Signup and view all the answers

Gas detectors should not be used in atmospheres with oxygen above 20.8% for accurate readings.

<p>False (B)</p> Signup and view all the answers

Process Isolation is a method used to allow a liquid or gas process stream to flow past a confined space.

<p>False (B)</p> Signup and view all the answers

A work permit is required for routine Maintenance activities performed by experienced employees inside the permanent Warehouses.

<p>False (B)</p> Signup and view all the answers

Forklifts driven by operators within Hazardous Areas do not require a work permit if designed for safe use in such locations.

<p>True (A)</p> Signup and view all the answers

Any operation work performed by unqualified contractors working under operation within their normal operating responsibilities does not require a work permit.

<p>False (B)</p> Signup and view all the answers

Visual inspections in operational areas require completion of the visitor's logbook according to the text.

<p>True (A)</p> Signup and view all the answers

Maintenance work inside Maintenance Workshops does not need a work permit according to the text.

<p>False (B)</p> Signup and view all the answers

It is required to notify the Security and Fire Sections when a work permit is not necessary for certain operations.

<p>False (B)</p> Signup and view all the answers

A confined entry permit must always be issued before any work can be conducted in internal combustion engine equipment operation areas.

<p>False (B)</p> Signup and view all the answers

Work permits are needed for energizing or de-energizing equipment but not for resetting tripped equipment.

<p>False (B)</p> Signup and view all the answers

In order to issue a work permit, it is not necessary to positively identify the equipment to be worked on.

<p>False (B)</p> Signup and view all the answers

All hot work activities inside the process/production areas require a Job Safety Analysis (JSA).

<p>True (A)</p> Signup and view all the answers

It is allowed to display a general tag on equipment for work to be performed.

<p>False (B)</p> Signup and view all the answers

Gas detectors should not be used in atmospheres with oxygen above 20.8% for accurate readings.

<p>False (B)</p> Signup and view all the answers

A rescue plan must be developed before issuing a confined entry permit under Category A.

<p>True (A)</p> Signup and view all the answers

The text specifies that tags can only be attached to equipment using specific adhesive methods.

<p>False (B)</p> Signup and view all the answers

Before starting work on equipment, it is essential to ensure that the process has been isolated from the general equipment.

<p>True (A)</p> Signup and view all the answers

All activities executed by ARC contractors do not require a Job Safety Analysis (JSA).

<p>False (B)</p> Signup and view all the answers

Threshold Limit Value (TLV) refers to the safe concentration of toxic gas above which it is not recommended to work for extended periods.

<p>False (B)</p> Signup and view all the answers

Continuous employee occupancy is intended for all types of confined spaces.

<p>False (B)</p> Signup and view all the answers

Gas testing is not required for confined space entry according to the text.

<p>False (B)</p> Signup and view all the answers

The text states that it is acceptable to use any means suitable for the application to attach tags to equipment for work.

<p>True (A)</p> Signup and view all the answers

Cold Work involves working on live electrical circuits according to the text.

<p>False (B)</p> Signup and view all the answers

Venting involves releasing gases or vapors to the atmosphere during purging activities.

<p>False (B)</p> Signup and view all the answers

Breathing apparatus can include canisters, cartridges, and filter masks according to the text.

<p>True (A)</p> Signup and view all the answers

Excavation Work can only be done using manual tools according to the text.

<p>False (B)</p> Signup and view all the answers

It is allowed to use TASNEE fire extinguishers for hot work by contractors.

<p>False (B)</p> Signup and view all the answers

During welding in confined spaces, gas-burning torches can be left unattended inside the space.

<p>False (B)</p> Signup and view all the answers

Compressed gas cylinders and welding machines are allowed inside confined spaces during welding.

<p>False (B)</p> Signup and view all the answers

Welding machines do not need to be grounded when welding in confined spaces.

<p>False (B)</p> Signup and view all the answers

If the removal of welding torches from a confined space is impractical, the hose at the regulator should be disconnected.

<p>True (A)</p> Signup and view all the answers

Gas cylinders must be kept inside the operating area at the end of any work period during arc welding.

<p>False (B)</p> Signup and view all the answers

Arc welding leads and oxy-acetylene hoses do not need to be inspected before use in confined spaces.

<p>False (B)</p> Signup and view all the answers

The electrode can be left in the electrode holder when arc welding is stopped for any reason.

<p>False (B)</p> Signup and view all the answers

More Like This

Hot Work Tools Quiz
2 questions

Hot Work Tools Quiz

GlowingTanzanite avatar
GlowingTanzanite
Hot Work Permit and Fire Safety Quiz
20 questions
Hot Work Permit Procedures
18 questions
Hot Work Safety Procedures
48 questions
Use Quizgecko on...
Browser
Browser