Hospital Infection Control

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the primary reason for inspecting devices under magnification?

  • To inspect the outer insulation coating of devices
  • To check for breakage of movable parts
  • To ensure devices are free from corrosion
  • To detect small pieces of bioburden or debris that may be difficult to see (correct)

Which of the following devices require close inspection to ensure the outer insulation coating remains intact?

  • Diathermy forceps (correct)
  • Cannulated devices
  • Ratchets
  • Telescopes and light cables

What is the purpose of checking hinges on devices such as artery forceps and clamps?

  • To check for alignment of jaws and teeth
  • To ensure ease of movement (correct)
  • To check for corrosion
  • To inspect for breakage

Which of the following devices should be checked for sharpness?

<p>Scissors, rongeurs, and chisels (B)</p> Signup and view all the answers

What should be done immediately upon discovering a damaged or malfunctioning device?

<p>Report it to the supervisor (C)</p> Signup and view all the answers

Why is it important to inspect devices for cleanliness and stains?

<p>To prevent the collection of dirt and bacteria (B)</p> Signup and view all the answers

What is the purpose of checking jaws and teeth on devices such as Kocker-Mosquito forceps?

<p>To check for alignment (C)</p> Signup and view all the answers

What is the purpose of function testing telescopes and light cables?

<p>To check according to the manufacturer's instructions (B)</p> Signup and view all the answers

What is the consequence of damaged surfaces on devices with an outer insulation coating?

<p>Dirt and bacteria may collect, and there may be a potential burn risk (D)</p> Signup and view all the answers

What is the purpose of checking cannulated devices?

<p>To ensure the channel is patent (clear) (A)</p> Signup and view all the answers

Flashcards

Why magnify devices?

To detect small bioburden or debris that's hard to see.

Insulation check?

Diathermy forceps should have intact insulation.

Hinge check purpose?

To ensure ease of movement during procedures.

Check for sharpness on?

Scissors, rongeurs, and chisels need to be sharp.

Signup and view all the flashcards

Damaged device action?

Report it immediately to the supervisor.

Signup and view all the flashcards

Cleanliness matters?

To prevent dirt and bacteria from collecting, causing infection.

Signup and view all the flashcards

Jaws and teeth ensure?

To check for proper alignment for effective gripping.

Signup and view all the flashcards

Test telescopes and cables?

Check according to the manufacturer's instructions.

Signup and view all the flashcards

Damaged insulation risk?

There may be a collection of dirt/bacteria, and a potential burn risk.

Signup and view all the flashcards

Cannulated devices importance?

To ensure the channel is patent (clear).

Signup and view all the flashcards