Podcast
Questions and Answers
What is the maximum percentage of oxygen that the device is approved to be used in?
What is the maximum percentage of oxygen that the device is approved to be used in?
What visual indication does the red alarm LED provide?
What visual indication does the red alarm LED provide?
What is the maximum number of sensors the ALTAIR 5X PID can accommodate?
What is the maximum number of sensors the ALTAIR 5X PID can accommodate?
Which LED directly indicates the device's Bluetooth status?
Which LED directly indicates the device's Bluetooth status?
Signup and view all the answers
How can alarm levels for individual gases be adjusted?
How can alarm levels for individual gases be adjusted?
Signup and view all the answers
What indication does the green LED provide on the device?
What indication does the green LED provide on the device?
Signup and view all the answers
What is indicated by the yellow 'Fault' LED on the device?
What is indicated by the yellow 'Fault' LED on the device?
Signup and view all the answers
What should you do before performing a calibration on the device?
What should you do before performing a calibration on the device?
Signup and view all the answers
What does a reading of 'XXX' on the device indicate?
What does a reading of 'XXX' on the device indicate?
Signup and view all the answers
What happens when a gas concentration reaches the LOW alarm set point?
What happens when a gas concentration reaches the LOW alarm set point?
Signup and view all the answers
How can a user clear the Lock Alarm state in the device?
How can a user clear the Lock Alarm state in the device?
Signup and view all the answers
What type of gas concentrations does the catalytic combustible sensor detect?
What type of gas concentrations does the catalytic combustible sensor detect?
Signup and view all the answers
What could serious personal injury or death result from while using the device?
What could serious personal injury or death result from while using the device?
Signup and view all the answers
In what units does the device display VOC gas concentrations?
In what units does the device display VOC gas concentrations?
Signup and view all the answers
What is the appropriate action if an alarm is triggered while using the device?
What is the appropriate action if an alarm is triggered while using the device?
Signup and view all the answers
What does the presence of a ♥ indicator on the display signify?
What does the presence of a ♥ indicator on the display signify?
Signup and view all the answers
What should a user do immediately upon startup if an alarm is triggered?
What should a user do immediately upon startup if an alarm is triggered?
Signup and view all the answers
If the device does not detect a pump flow block during startup, what message will be displayed?
If the device does not detect a pump flow block during startup, what message will be displayed?
Signup and view all the answers
What action is appropriate if the device shuts OFF after an error message?
What action is appropriate if the device shuts OFF after an error message?
Signup and view all the answers
What safety measure should not be overlooked while using the device?
What safety measure should not be overlooked while using the device?
Signup and view all the answers
What is the purpose of the Fresh Air Setup (FAS) feature?
What is the purpose of the Fresh Air Setup (FAS) feature?
Signup and view all the answers
When should the Fresh Air Setup not be performed?
When should the Fresh Air Setup not be performed?
Signup and view all the answers
What could occur if liquid is drawn into the device?
What could occur if liquid is drawn into the device?
Signup and view all the answers
What occurs if the Fresh Air Setup fails?
What occurs if the Fresh Air Setup fails?
Signup and view all the answers
What does the display indicate while the oxygen sensor is undergoing a 'cook down'?
What does the display indicate while the oxygen sensor is undergoing a 'cook down'?
Signup and view all the answers
What action is prevented during the oxygen sensor's cook down period?
What action is prevented during the oxygen sensor's cook down period?
Signup and view all the answers
Which page in Measurement Mode shows the peak readings for all sensors?
Which page in Measurement Mode shows the peak readings for all sensors?
Signup and view all the answers
Under which condition might the oxygen sensor display be suppressed at device turn-on?
Under which condition might the oxygen sensor display be suppressed at device turn-on?
Signup and view all the answers
Which of the following procedures may be performed once the oxygen reading appears after cook down?
Which of the following procedures may be performed once the oxygen reading appears after cook down?
Signup and view all the answers
What does the STEL Page show in Measurement Mode?
What does the STEL Page show in Measurement Mode?
Signup and view all the answers
Study Notes
Device Overview
- Monitors gases in ambient air and workplace environments.
- ALTAIR 5X PID equipped with a maximum of five sensors; can display readings for up to six gases.
- Two-Tox Sensor allows detection of CO and H2S or CO and NO2 in one unit.
- Device features a color display and factory-set alarm levels adjustable via Instrument Setup Menu or MSA Link Software.
Gas Monitoring Capabilities
-
Combustible Gases:
- Catalytic sensor detects gases up to 100% LEL (Lower Explosive Limit); displays as % LEL or % CH4.
- Two alarm setpoints: HIGH and LOW; alert user to dangerous concentrations.
- Lock Alarm state engages when readings exceed 100% LEL; device shows "XXX" instead of actual reading.
-
VOC Gases:
- PID sensor detects various VOC gases; readings displayed in ppm, µmol/mol, or mg/m³.
- Can detect up to 30% oxygen but approved for use up to 21%.
Device Hardware Interfaces
- Operation facilitated through three function buttons:
- q Button: Power On/Off and confirms selections.
- Button: Pages down, decreases values, starts Bump Test. Accessible features depend on user permissions.
- Button: Resets values, performs calibration, pages up, or increases settings.
LED Indicators
- Red Alarm LEDs: Visual alerts for alarm conditions or device errors.
- ♥ indicator signals sensor nearing end-of-life.
Safety Features
- Sampling system undergoes a safety test at startup; failure to block flow triggers an error message.
- Pump alarm must activate when sampling line is blocked; absence of alarm may result in inaccurate readings and potential hazards.
Fresh Air Setup (FAS)
- Automatic zero adjustment initiated at device turn-on.
- FAS cannot be performed if a hazardous gas is present; device alarm activates in such cases.
- Inaccurate readings can result from unclean air during FAS; daily calibration checks are essential.
Oxygen Sensor Considerations
- Oxygen sensor readings may be suppressed for up to 30 minutes during 'cook down' after installation or battery issues.
- Displays "PLEASE WAIT" during this period; prevents Fresh Air Setup, Calibration, or Bump Test until oxygen reading stabilizes.
Measurement Mode Features
- Measurement screen provides access to:
- BUMP Page: Undertakes Bump Test for sensors.
- Peak Page: Shows peak readings for all sensors.
- Min Page: Displays minimum oxygen sensor readings.
- STEL Page: Shows calculated Short Term Exposure Limit readings.
- TWA Page: Shows calculated Time Weighted Average readings.
- Date Page: Displays current date settings on the device.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
Explore the features and capabilities of the ALTAIR 5X PID gas monitoring device. This quiz covers its gas detection functions, alarm systems, and user interfaces designed for safety in various environments. Understand how this technology enhances workplace safety by monitoring multiple gases.