What is the maximum percentage of oxygen that the device is approved to be used in?

  • 25%
  • 30%
  • 21% (correct)
  • 15%
  • What visual indication does the red alarm LED provide?

  • Battery life status
  • Alarm condition or error (correct)
  • Normal operation
  • Charging status
  • What is the maximum number of sensors the ALTAIR 5X PID can accommodate?

  • Four sensors
  • Six sensors
  • Five sensors (correct)
  • Three sensors
  • Which LED directly indicates the device's Bluetooth status?

    <p>Bluetooth Status LED</p> Signup and view all the answers

    How can alarm levels for individual gases be adjusted?

    <p>Using the Instrument Setup Menu or MSA Link Software</p> Signup and view all the answers

    What indication does the green LED provide on the device?

    <p>Device is safe</p> Signup and view all the answers

    What is indicated by the yellow 'Fault' LED on the device?

    <p>There is an operational issue with the device</p> Signup and view all the answers

    What should you do before performing a calibration on the device?

    <p>Ensure the device is in known fresh air</p> Signup and view all the answers

    What does a reading of 'XXX' on the device indicate?

    <p>The atmosphere may be above 100 % LEL</p> Signup and view all the answers

    What happens when a gas concentration reaches the LOW alarm set point?

    <p>Alarm message displays and sounds</p> Signup and view all the answers

    How can a user clear the Lock Alarm state in the device?

    <p>Turn the device OFF and then ON again in fresh air</p> Signup and view all the answers

    What type of gas concentrations does the catalytic combustible sensor detect?

    <p>Combustible gases up to 100 % LEL</p> Signup and view all the answers

    What could serious personal injury or death result from while using the device?

    <p>Remaining in an area after an alarm is triggered</p> Signup and view all the answers

    In what units does the device display VOC gas concentrations?

    <p>Parts per million, µmol/mol, or mg/m3</p> Signup and view all the answers

    What is the appropriate action if an alarm is triggered while using the device?

    <p>Leave the area immediately</p> Signup and view all the answers

    What does the presence of a ♥ indicator on the display signify?

    <p>A sensor is approaching end-of-life</p> Signup and view all the answers

    What should a user do immediately upon startup if an alarm is triggered?

    <p>Block the pumps/sampling system</p> Signup and view all the answers

    If the device does not detect a pump flow block during startup, what message will be displayed?

    <p>ERROR</p> Signup and view all the answers

    What action is appropriate if the device shuts OFF after an error message?

    <p>Press the button to acknowledge and check the sampling system</p> Signup and view all the answers

    What safety measure should not be overlooked while using the device?

    <p>DO check for pump alarm activation when blocking the flow</p> Signup and view all the answers

    What is the purpose of the Fresh Air Setup (FAS) feature?

    <p>To automatically adjust to zero readings</p> Signup and view all the answers

    When should the Fresh Air Setup not be performed?

    <p>If fresh, uncontaminated air is not certain</p> Signup and view all the answers

    What could occur if liquid is drawn into the device?

    <p>Results could be inaccurate and damage the device</p> Signup and view all the answers

    What occurs if the Fresh Air Setup fails?

    <p>The user must perform a zero calibration.</p> Signup and view all the answers

    What does the display indicate while the oxygen sensor is undergoing a 'cook down'?

    <p>PLEASE WAIT</p> Signup and view all the answers

    What action is prevented during the oxygen sensor's cook down period?

    <p>Bump Test procedure</p> Signup and view all the answers

    Which page in Measurement Mode shows the peak readings for all sensors?

    <p>Peak Page</p> Signup and view all the answers

    Under which condition might the oxygen sensor display be suppressed at device turn-on?

    <p>When the oxygen sensor is just installed.</p> Signup and view all the answers

    Which of the following procedures may be performed once the oxygen reading appears after cook down?

    <p>Calibrate the oxygen sensor</p> Signup and view all the answers

    What does the STEL Page show in Measurement Mode?

    <p>Short-term exposure limit readings</p> Signup and view all the answers

    Study Notes

    Device Overview

    • Monitors gases in ambient air and workplace environments.
    • ALTAIR 5X PID equipped with a maximum of five sensors; can display readings for up to six gases.
    • Two-Tox Sensor allows detection of CO and H2S or CO and NO2 in one unit.
    • Device features a color display and factory-set alarm levels adjustable via Instrument Setup Menu or MSA Link Software.

    Gas Monitoring Capabilities

    • Combustible Gases:

      • Catalytic sensor detects gases up to 100% LEL (Lower Explosive Limit); displays as % LEL or % CH4.
      • Two alarm setpoints: HIGH and LOW; alert user to dangerous concentrations.
      • Lock Alarm state engages when readings exceed 100% LEL; device shows "XXX" instead of actual reading.
    • VOC Gases:

      • PID sensor detects various VOC gases; readings displayed in ppm, µmol/mol, or mg/m³.
      • Can detect up to 30% oxygen but approved for use up to 21%.

    Device Hardware Interfaces

    • Operation facilitated through three function buttons:
      • q Button: Power On/Off and confirms selections.
      •  Button: Pages down, decreases values, starts Bump Test. Accessible features depend on user permissions.
      •  Button: Resets values, performs calibration, pages up, or increases settings.

    LED Indicators

    • Red Alarm LEDs: Visual alerts for alarm conditions or device errors.
    • ♥ indicator signals sensor nearing end-of-life.

    Safety Features

    • Sampling system undergoes a safety test at startup; failure to block flow triggers an error message.
    • Pump alarm must activate when sampling line is blocked; absence of alarm may result in inaccurate readings and potential hazards.

    Fresh Air Setup (FAS)

    • Automatic zero adjustment initiated at device turn-on.
    • FAS cannot be performed if a hazardous gas is present; device alarm activates in such cases.
    • Inaccurate readings can result from unclean air during FAS; daily calibration checks are essential.

    Oxygen Sensor Considerations

    • Oxygen sensor readings may be suppressed for up to 30 minutes during 'cook down' after installation or battery issues.
    • Displays "PLEASE WAIT" during this period; prevents Fresh Air Setup, Calibration, or Bump Test until oxygen reading stabilizes.

    Measurement Mode Features

    • Measurement screen provides access to:
      • BUMP Page: Undertakes Bump Test for sensors.
      • Peak Page: Shows peak readings for all sensors.
      • Min Page: Displays minimum oxygen sensor readings.
      • STEL Page: Shows calculated Short Term Exposure Limit readings.
      • TWA Page: Shows calculated Time Weighted Average readings.
      • Date Page: Displays current date settings on the device.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Related Documents

    ALTAIR 5X PID.pdf

    Description

    Explore the features and capabilities of the ALTAIR 5X PID gas monitoring device. This quiz covers its gas detection functions, alarm systems, and user interfaces designed for safety in various environments. Understand how this technology enhances workplace safety by monitoring multiple gases.