What is the maximum percentage of oxygen that the device is approved to be used in?

  • 25%
  • 30%
  • 21% (correct)
  • 15%

What visual indication does the red alarm LED provide?

  • Battery life status
  • Alarm condition or error (correct)
  • Normal operation
  • Charging status

What is the maximum number of sensors the ALTAIR 5X PID can accommodate?

  • Four sensors
  • Six sensors
  • Five sensors (correct)
  • Three sensors

Which LED directly indicates the device's Bluetooth status?

<p>Bluetooth Status LED (B)</p> Signup and view all the answers

How can alarm levels for individual gases be adjusted?

<p>Using the Instrument Setup Menu or MSA Link Software (A)</p> Signup and view all the answers

What indication does the green LED provide on the device?

<p>Device is safe (D)</p> Signup and view all the answers

What is indicated by the yellow 'Fault' LED on the device?

<p>There is an operational issue with the device (D)</p> Signup and view all the answers

What should you do before performing a calibration on the device?

<p>Ensure the device is in known fresh air (D)</p> Signup and view all the answers

What does a reading of 'XXX' on the device indicate?

<p>The atmosphere may be above 100 % LEL (A)</p> Signup and view all the answers

What happens when a gas concentration reaches the LOW alarm set point?

<p>Alarm message displays and sounds (C)</p> Signup and view all the answers

How can a user clear the Lock Alarm state in the device?

<p>Turn the device OFF and then ON again in fresh air (A)</p> Signup and view all the answers

What type of gas concentrations does the catalytic combustible sensor detect?

<p>Combustible gases up to 100 % LEL (B)</p> Signup and view all the answers

What could serious personal injury or death result from while using the device?

<p>Remaining in an area after an alarm is triggered (B)</p> Signup and view all the answers

In what units does the device display VOC gas concentrations?

<p>Parts per million, µmol/mol, or mg/m3 (D)</p> Signup and view all the answers

What is the appropriate action if an alarm is triggered while using the device?

<p>Leave the area immediately (C)</p> Signup and view all the answers

What does the presence of a ♥ indicator on the display signify?

<p>A sensor is approaching end-of-life (C)</p> Signup and view all the answers

What should a user do immediately upon startup if an alarm is triggered?

<p>Block the pumps/sampling system (A)</p> Signup and view all the answers

If the device does not detect a pump flow block during startup, what message will be displayed?

<p>ERROR (A)</p> Signup and view all the answers

What action is appropriate if the device shuts OFF after an error message?

<p>Press the button to acknowledge and check the sampling system (D)</p> Signup and view all the answers

What safety measure should not be overlooked while using the device?

<p>DO check for pump alarm activation when blocking the flow (A)</p> Signup and view all the answers

What is the purpose of the Fresh Air Setup (FAS) feature?

<p>To automatically adjust to zero readings (B)</p> Signup and view all the answers

When should the Fresh Air Setup not be performed?

<p>If fresh, uncontaminated air is not certain (C)</p> Signup and view all the answers

What could occur if liquid is drawn into the device?

<p>Results could be inaccurate and damage the device (A)</p> Signup and view all the answers

What occurs if the Fresh Air Setup fails?

<p>The user must perform a zero calibration. (D)</p> Signup and view all the answers

What does the display indicate while the oxygen sensor is undergoing a 'cook down'?

<p>PLEASE WAIT (C)</p> Signup and view all the answers

What action is prevented during the oxygen sensor's cook down period?

<p>Bump Test procedure (C)</p> Signup and view all the answers

Which page in Measurement Mode shows the peak readings for all sensors?

<p>Peak Page (C)</p> Signup and view all the answers

Under which condition might the oxygen sensor display be suppressed at device turn-on?

<p>When the oxygen sensor is just installed. (B)</p> Signup and view all the answers

Which of the following procedures may be performed once the oxygen reading appears after cook down?

<p>Calibrate the oxygen sensor (C)</p> Signup and view all the answers

What does the STEL Page show in Measurement Mode?

<p>Short-term exposure limit readings (B)</p> Signup and view all the answers

Flashcards are hidden until you start studying

Study Notes

Device Overview

  • Monitors gases in ambient air and workplace environments.
  • ALTAIR 5X PID equipped with a maximum of five sensors; can display readings for up to six gases.
  • Two-Tox Sensor allows detection of CO and H2S or CO and NO2 in one unit.
  • Device features a color display and factory-set alarm levels adjustable via Instrument Setup Menu or MSA Link Software.

Gas Monitoring Capabilities

  • Combustible Gases:

    • Catalytic sensor detects gases up to 100% LEL (Lower Explosive Limit); displays as % LEL or % CH4.
    • Two alarm setpoints: HIGH and LOW; alert user to dangerous concentrations.
    • Lock Alarm state engages when readings exceed 100% LEL; device shows "XXX" instead of actual reading.
  • VOC Gases:

    • PID sensor detects various VOC gases; readings displayed in ppm, µmol/mol, or mg/m³.
    • Can detect up to 30% oxygen but approved for use up to 21%.

Device Hardware Interfaces

  • Operation facilitated through three function buttons:
    • q Button: Power On/Off and confirms selections.
    •  Button: Pages down, decreases values, starts Bump Test. Accessible features depend on user permissions.
    •  Button: Resets values, performs calibration, pages up, or increases settings.

LED Indicators

  • Red Alarm LEDs: Visual alerts for alarm conditions or device errors.
  • ♥ indicator signals sensor nearing end-of-life.

Safety Features

  • Sampling system undergoes a safety test at startup; failure to block flow triggers an error message.
  • Pump alarm must activate when sampling line is blocked; absence of alarm may result in inaccurate readings and potential hazards.

Fresh Air Setup (FAS)

  • Automatic zero adjustment initiated at device turn-on.
  • FAS cannot be performed if a hazardous gas is present; device alarm activates in such cases.
  • Inaccurate readings can result from unclean air during FAS; daily calibration checks are essential.

Oxygen Sensor Considerations

  • Oxygen sensor readings may be suppressed for up to 30 minutes during 'cook down' after installation or battery issues.
  • Displays "PLEASE WAIT" during this period; prevents Fresh Air Setup, Calibration, or Bump Test until oxygen reading stabilizes.

Measurement Mode Features

  • Measurement screen provides access to:
    • BUMP Page: Undertakes Bump Test for sensors.
    • Peak Page: Shows peak readings for all sensors.
    • Min Page: Displays minimum oxygen sensor readings.
    • STEL Page: Shows calculated Short Term Exposure Limit readings.
    • TWA Page: Shows calculated Time Weighted Average readings.
    • Date Page: Displays current date settings on the device.

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

Related Documents

ALTAIR® 5X PID PDF

More Like This

Arterial Blood Gas Monitoring Overview
29 questions
Gas Exchange Analysis and Monitoring
40 questions
Use Quizgecko on...
Browser
Browser