Under UDCPR 7.12, what is the maximum FSI permitted for commercial buildings in a CBD or Commercial Zone?
Under UDCPR 7.12, what is the maximum FSI permitted for commercial buildings in a CBD or Commercial Zone?
- 2.50
- 3.00
- 4.00
- 5.00 (correct)
When calculating permissible FSI under Regulation 7.12, which regulation table should be consulted first before claiming additional FSI?
When calculating permissible FSI under Regulation 7.12, which regulation table should be consulted first before claiming additional FSI?
- Table 7-A
- Table 11-A
- Table 6-B
- Table 6-G (correct)
What is the minimum road width required for developing commercial buildings under Regulation 7.12?
What is the minimum road width required for developing commercial buildings under Regulation 7.12?
- 24 m
- 18 m
- 9 m
- 12 m (correct)
According to Regulation 7.12, what percentage of the permissible FSI can be allocated for residential use?
According to Regulation 7.12, what percentage of the permissible FSI can be allocated for residential use?
What is the premium rate applicable for additional FSI under Regulation 7.12?
What is the premium rate applicable for additional FSI under Regulation 7.12?
How is the premium shared between the government and the authority for additional FSI under Regulation 7.12?
How is the premium shared between the government and the authority for additional FSI under Regulation 7.12?
Which type of development is exempt from the Inclusive Housing requirement under Regulation 7.12?
Which type of development is exempt from the Inclusive Housing requirement under Regulation 7.12?
According to Regulation 7.12, where is commercial development allowed?
According to Regulation 7.12, where is commercial development allowed?
In an industrial zone, under what condition is Regulation 7.12 applicable?
In an industrial zone, under what condition is Regulation 7.12 applicable?
Which regulation must be complied with before allowing additional FSI under Regulation 7.12?
Which regulation must be complied with before allowing additional FSI under Regulation 7.12?
Flashcards
Max FSI for Commercial Buildings
Max FSI for Commercial Buildings
The maximum FSI allowed for commercial buildings in CBD or Commercial Zone is 5.00.
FSI Calculation Table
FSI Calculation Table
Table 6-G must be referred to first while calculating permissible FSI before claiming additional FSI under Regulation 7.12.
Minimum Road Width
Minimum Road Width
Minimum required road width for development of commercial buildings is 12 m.
Residential FSI Percentage
Residential FSI Percentage
Signup and view all the flashcards
Premium for Additional FSI
Premium for Additional FSI
Signup and view all the flashcards
Premium Sharing
Premium Sharing
Signup and view all the flashcards
Exempted Development
Exempted Development
Signup and view all the flashcards
Allowed Development Zones
Allowed Development Zones
Signup and view all the flashcards
Regulation 7.12 in Industrial Zone
Regulation 7.12 in Industrial Zone
Signup and view all the flashcards
Compliance Regulation
Compliance Regulation
Signup and view all the flashcards
Study Notes
- The maximum Floor Space Index (FSI) allowed for commercial buildings in Central Business District (CBD) or Commercial Zones is 5.00.
- To calculate permissible FSI before claiming additional FSI under Regulation 7.12, Table 6-G must be referred to first.
- The minimum required road width for development of commercial buildings under this provision is 12 meters.
- Up to 30% of the permissible FSI can be used for residential purposes under Regulation 7.12.
- The premium rate applicable for additional FSI under Regulation 7.12 is 50% of the Annual Statement of Rates (ASR).
- The premium for additional FSI under this regulation is shared with 50% going to the Government and 50% to the Authority.
- Commercial buildings in CBD, Residential, and Commercial zones are exempt from Inclusive Housing requirements under Regulation 7.12.
- Commercial development can occur in CBD, Residential Zones, or Industrial Zones where commercial use is permitted.
- In an industrial zone, Regulation 7.12 is applicable only if residential or commercial use is allowed.
- Regulation 4.8.1 must be complied with before allowing additional FSI.