What is the standard nozzle pressure for interior 1 3/4" lines with fog nozzles?

  • 60 psi (correct)
  • 80 psi
  • 50 psi
  • 100 psi
  • What is the GPM flow for exterior master streams with a 1 1/2" tip?

  • 500 GPM
  • 800 GPM
  • 600 GPM (correct)
  • 400 GPM
  • What is the nozzle pressure for exterior handlines using a 250 GPM fog nozzle?

  • 60 psi (correct)
  • 50 psi
  • 80 psi
  • 100 psi
  • What is the GPM flow for smooth bore nozzles with a 1 1/4" tip?

    <p>300 GPM</p> Signup and view all the answers

    What is the standard nozzle pressure for smooth bore nozzles?

    <p>50 psi</p> Signup and view all the answers

    What is the GPM flow for fog nozzles set at 250 GPM on the nozzle selector?

    <p>250 GPM</p> Signup and view all the answers

    What is the nozzle pressure for exterior master streams with a fog nozzle?

    <p>100 psi</p> Signup and view all the answers

    What is the GPM flow for exterior master streams with a 2" tip?

    <p>1000 GPM</p> Signup and view all the answers

    What is the initial engine discharge pressure that must be maintained for all pumpers supporting a sprinkler and/or standpipe system?

    <p>150 psi</p> Signup and view all the answers

    If a building is equipped with a fire pump and the initial discharge pressure of 150 psi is overcoming the fire pump, what should be done with the engine discharge pressure?

    <p>Increase it as if the building did not have a fire pump</p> Signup and view all the answers

    What is the flow rate of the in-line foam eductors?

    <p>95 GPM</p> Signup and view all the answers

    What is the inlet pressure that the in-line foam eductors are calibrated for?

    <p>200 psi</p> Signup and view all the answers

    How much AR-Synthetic Universal Green 3% foam is carried on each engine?

    <p>30 gallons</p> Signup and view all the answers

    What is the setting on the fog nozzle that must be used when applying foam?

    <p>95 setting</p> Signup and view all the answers

    What type of foam is produced when using a foam aspirating nozzle?

    <p>Thicker, better foam</p> Signup and view all the answers

    When can foam be used for firefighting operations?

    <p>Only after all other suppression options have been exhausted</p> Signup and view all the answers

    What is the minimum pressure that should be maintained on the suction side of the supply pumper?

    <p>20 psi</p> Signup and view all the answers

    What is the maximum pressure that should be maintained on the discharge side of the relay pumping system?

    <p>200 psi</p> Signup and view all the answers

    Which of the following is NOT a step in setting up a relay pumping system?

    <p>Connecting the attack hose to the hydrant steamer connection</p> Signup and view all the answers

    Why should pumpers keep at least 100 feet of hose in reserve?

    <p>To allow for hoseline bursts</p> Signup and view all the answers

    What is the primary purpose of flushing the hydrant before connecting to it?

    <p>To ensure the hydrant is in working condition</p> Signup and view all the answers

    What is the correct method for connecting a hose to a hydrant steamer connection?

    <p>Use a soft sleeve</p> Signup and view all the answers

    Which of the following actions should be taken by the attack pump operator in a relay pumping system?

    <p>Adjust the discharge pressure</p> Signup and view all the answers

    What is the main purpose of bleeding air from the supply hose in a relay pumping system?

    <p>To ensure a smooth flow of water</p> Signup and view all the answers

    Study Notes

    Fire Stream Management

    Standard Operating Pressures and GPM Flows

    • Interior 1 3/4" lines: nozzle pressure of 60 psi (fog nozzles) or 50 psi (smooth bore nozzles), calculated at 200 GPM
    • Exterior handlines with 250 GPM fog nozzles: same as interior lines
    • Smooth bore nozzles: calculated with nozzle pressure of 50 psi and GPM flows of 200, 250, or 300 depending on tip size
    • Exterior master streams: nozzle pressure of 100 psi (fog nozzles) or 80 psi (smooth bore nozzles), with GPM flows ranging from 400 to 1000 depending on tip size

    Engine Discharge Pressure

    • Initial engine discharge pressure: 150 psi for pumpers supporting sprinkler and/or standpipe systems
    • Adjustments to engine discharge pressure:
      • If building not equipped with fire pump, increase to maintain standard operating pressures and GPM flows
      • If building equipped with fire pump and initial discharge pressure of 150 psi is overcoming fire pump, increase engine discharge pressure
      • If building equipped with fire pump and initial discharge pressure of 150 psi is not overcoming fire pump, shut down pumper and use building's fire pump

    Foam Operations

    • In-line foam eductors: 95 GPM units, calibrated for 200 psi inlet pressure
    • Foam eductors capable of handling 300 feet of 1 3/4" hose after eductor
    • Foam concentration: 3%
    • Foam application: can be used with standard fog nozzle or foam aspirating nozzle

    Hydrant Connections

    • Flush hydrant to ensure working condition and remove debris prior to hooking up hose or appliance
    • Use soft sleeve or 5" LDH connected to hydrant steamer connection
    • If no steamer port, use adaptors to connect to 2 ½” port(s)

    Relay Pumping

    • First-arriving engine positions at fire, with Company Officer determining water needed
    • Initial attack made with water carried on pumper
    • Relay setup with largest capacity pumper at water source
    • Pumpers keep at least 100 feet of hose in reserve for hoseline bursts
    • Pump operators (except supply) bleed air from supply hose using Master Intake Valve (MIV)
    • Pumper at water source starts at idle, maintaining 20 psi residual and adding 20 psi for relay
    • Attack pumper operator informs other pump operators of water needed
    • Supply pumper throttle adjusted to reach operating pressure, with discharge pressure not exceeding 200 psi and residual pressure not falling below 20 psi

    Studying That Suits You