Questions and Answers

What is the required frequency for checking special extinguishing systems?

  • Every 6 months (correct)
  • Annually
  • Every 3 years
  • Every month
  • What is the minimum exit requirement for buildings with two or more exits?

  • Monthly
  • Every 3 years
  • Every year (correct)
  • Every 6 months
  • How much space should be allowed between stored items and walls to accommodate swelling?

  • 3 feet
  • 4 feet
  • 2 feet (correct)
  • 1 foot
  • Which of the following is NOT a check included in the prohibited storage section?

    <p>Check for proper aisle clearance</p> Signup and view all the answers

    What must be verified regarding fire extinguishers during an inspection?

    <p>Last service date</p> Signup and view all the answers

    According to building occupancy regulations, what is the occupant factor related to exits?

    <p>Defines exit requirements based on occupancy</p> Signup and view all the answers

    What is the consequence of non-compliance in the disclosure of hazardous substances check?

    <p>Fines and penalties</p> Signup and view all the answers

    For indoor storage, which of the following is essential to check for efficiency?

    <p>Pallet storage arrangements</p> Signup and view all the answers

    What is the minimum height for block letters on exit signs according to the regulations?

    <p>六 inches</p> Signup and view all the answers

    Which of the following is a requirement for illuminating exit signs?

    <p>They must be lighted whenever the building is occupied.</p> Signup and view all the answers

    What is required for storing Class II or Class III liquids in basements?

    <p>Approval and a Special Permit are required when certain conditions are met.</p> Signup and view all the answers

    What should be done if there are holes or cracks in fire-resistive construction?

    <p>They must be returned to their original fire resistive condition.</p> Signup and view all the answers

    Where is the storage of combustible materials prohibited?

    <p>Under staircases or in specified utility areas.</p> Signup and view all the answers

    What is the requirement for hazards on roofs or balconies?

    <p>No hazardous materials should be stored or placed there.</p> Signup and view all the answers

    What ensures compliance with the requirements for electrical internally lit exit signs?

    <p>Compliance with Chapter 9 of the L.A.M.C.</p> Signup and view all the answers

    What is the stroke width requirement for letters on exit signs?

    <p>Not less than 3/4 inch.</p> Signup and view all the answers

    What is prohibited regarding the installation of structures concerning fire hydrants and fire protection equipment?

    <p>Leaving vegetation around fire protection equipment.</p> Signup and view all the answers

    What must exit doors in a building be able to do according to the regulations?

    <p>Be opened from the inside without a key.</p> Signup and view all the answers

    What is the consequence of willfully tampering with fire protection equipment?

    <p>It can create a fire hazard and is prohibited.</p> Signup and view all the answers

    What signage requirement is stated for main entrance exit doors in Group B Occupancy?

    <p>It must state 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS.'</p> Signup and view all the answers

    Which of the following is a requirement for maintaining fire protection equipment?

    <p>It must not be kept in a state of disrepair.</p> Signup and view all the answers

    How should parking be regulated concerning fire hydrants?

    <p>Vehicles must not hinder complete access to fire protection equipment.</p> Signup and view all the answers

    In which situation is it acceptable to have locked exit doors?

    <p>If a sign states it remains unlocked during business hours.</p> Signup and view all the answers

    What is a key aspect of the regulations concerning fire safety signage?

    <p>Effective signage must use contrasting colors to be visible.</p> Signup and view all the answers

    Study Notes

    Safety Inspections and Exit Requirements

    • Internally illuminated exit signs must be activated at all times to ensure visibility during emergencies.
    • Properly serviced and located fire extinguishers should be checked throughout the building, including verification of the last service date.

    Indoor Storage Standards

    • Aisles and main aisles must be clear and appropriately sized to facilitate safe egress.
    • Storage piles must conform to designated height and size regulations to prevent hazards.
    • Maintain a two-foot clearance between stored items and walls to allow for material swelling.

    Prohibited Storage Areas

    • Illegal storage activities must be monitored, particularly in basements, on roofs, under stairs, and in general prohibited areas to reduce fire risk.

    Fire Code Compliance for Commercial Occupancies

    • Inspections follow an annual cycle if two or more exits are present; otherwise, it is every three years for single-exit facilities.

    Special Extinguishing Systems

    • Fire suppression systems require servicing every six months, with verification of service dates as part of inspections.

    Hazardous Substance Disclosure

    • Compliance certificates for hazardous substances must be checked to ensure safety regulations are met.

    Exit Requirements by Occupant Load

    • At least two exits are needed based on occupancy load as outlined in Table 33-A.

    Fire Hydrant Accessibility

    • Structures must not block access to fire hydrants or other fire protection equipment.
    • Vehicles should not obstruct fire department access to emergency equipment.

    Maintenance of Fire Protection Equipment

    • Maintain all fire safety equipment in functioning condition and refrain from tampering or damaging these devices.

    Exit Door Regulations

    • Exit doors must be operable without a key, tool, or special effort from the inside.
    • Signs indicating that doors remain unlocked during business hours must be clearly posted when applicable.

    Exit Sign Specifications

    • Exit signs must feature block letters at least six inches tall with a contrasting background.
    • Signs must be illuminated whenever the building is occupied to ensure clear visibility.

    Fire-Resistive Construction

    • Ensure all holes, cracks, or openings in fire-resistive structures are sealed to maintain compliance with safety codes.

    Basement Storage Regulations

    • Strict regulations forbid flammable liquid storage in residential building basements.
    • Certain Class II and III liquids may be stored in basements with proper permits and fire protection systems in place.

    Roof Storage Restrictions

    • Hazardous materials and any items obstructing egress or emergency actions must not be stored on roofs or balconies.

    General Prohibition Areas

    • Storing flammable materials or equipment in specified areas like attics, boiler rooms, or electrical panels is strictly forbidden to mitigate fire hazards.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Related Documents

    Description

    This quiz focuses on essential fire safety inspection procedures, including the verification of illuminated exit signs, the condition of fire extinguishers, and the organization of indoor storage areas. Understanding these safety measures is crucial for maintaining a safe environment in any building.