SOG 18 Fire Rescue Water Supply Operations Procedures Quiz
45 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the preferable psi that should be reached when increasing engine rpm?

  • 50 psi
  • 100 psi (correct)
  • 90 psi
  • 75 psi

When attaching the supply line to the gated intake valve of the Relay Pumper, what should the operator do?

  • Keep the gate open and open the bleeder valve
  • Keep the gate closed and close the bleeder valve
  • Keep the gate open and close the bleeder valve
  • Keep the gate closed and open the bleeder valve (correct)

What should the Attack Pumper operator do when the pumper is receiving excess pressure?

  • Decrease the throttle speed to reduce the output pressure
  • Open the bleeder valve to release the excess pressure
  • Adjust through a waste line valve to limit the residual psi (correct)
  • Increase the discharge valve to supply more pressure

What should all pump operators do when operating in a constant pressure relay?

<p>Maintain 100 psi (A)</p> Signup and view all the answers

When operating from a hydrant, what happens once the residual pressure at the source pumper drops to 20 psi?

<p>The relay capacity has been met (B)</p> Signup and view all the answers

What should the source and relay pumpers do when operating in an exact pressure relay?

<p>Send water according to GPM being used (A)</p> Signup and view all the answers

When operating the relay, what should engines with pressure governors be set to?

<p>RPM mode (B)</p> Signup and view all the answers

When shutting down the relay, in what order should the pumpers be shut down?

<p>Attack pumper first, working backwards from fire scene to source pumper (A)</p> Signup and view all the answers

What is the maximum working pressure recommended for a relay operation?

<p>200 psi (D)</p> Signup and view all the answers

When preparing to draft from a dry hydrant, what is the first step the truck operator should take?

<p>Spot the truck near the dry hydrant (C)</p> Signup and view all the answers

What should the dumpsite ideally have to allow for multiple apparatus to access it?

<p>Access from two sides (D)</p> Signup and view all the answers

What should the tanker operator leave for the drafting engine to utilize?

<p>Low-level strainer (A)</p> Signup and view all the answers

In addition to dumping its contents into the dump tank, what must the tanker operator assist with after arriving at the site?

<p>Setting up water supply (C)</p> Signup and view all the answers

What should be attached to both 2 1⁄2” outlets if the water supply is from a hydrant?

<p>2 1⁄2” ball valve and a section of 2 1⁄2” or 3” hose (C)</p> Signup and view all the answers

When can the tanker apparatus be considered as a means of relay pumping?

<p>When appropriate (A)</p> Signup and view all the answers

What is the purpose of a forward lay?

<p>A method of laying hose from the water supply to the fire scene (D)</p> Signup and view all the answers

What is a split lay?

<p>A hose lay laid by two pumpers, one making a forward lay, the other making a reverse lay, from the same point (D)</p> Signup and view all the answers

What are the indications of a working fire?

<p>Multiple calls, smoke or flames visible from the nearest hydrant location (C)</p> Signup and view all the answers

What should be contained in a hydrant bag on a suppression apparatus?

<p>A hydrant wrench, two LDH spanner wrenches, two spanner wrenches, and two 2 1⁄2&quot; ball valves (A)</p> Signup and view all the answers

When selecting a hydrant during water supply operations, what is the most important factor to consider?

<p>The location and flow rate of the desired hydrant (D)</p> Signup and view all the answers

When selecting a static water source, what is the most important factor?

<p>The amount of water available (A)</p> Signup and view all the answers

What should be associated with a water source during water supply operations?

<p>An exact geographic location (B)</p> Signup and view all the answers

Who is responsible for ensuring the establishment of a continuous water supply?

<p>The officer/engineer riding on the second due engine, unless otherwise directed by Incident Command (C)</p> Signup and view all the answers

What should be indicated with a radio benchmark during water supply operations?

<p>&quot;Water supply established&quot; (A)</p> Signup and view all the answers

What should be done if a structural fire is located down a long driveway?

<p>The first arriving engine should lay a supply line down the drive if visual conditions (smoke and/or fire) are present (B)</p> Signup and view all the answers

What is the maximum speed that should be used when performing a hose lay?

<p>15 MPH (D)</p> Signup and view all the answers

When should source pumping for structure fires be considered?

<p>For any supply lay greater than 500 feet (A)</p> Signup and view all the answers

What is the minimum additional GPM that each 2 1/2" hydrant discharge used in a heavy hydrant hookup should supply?

<p>250 GPM (D)</p> Signup and view all the answers

What should the source pumper do while waiting for the relay/attack pumper to be ready?

<p>Circulate water utilizing the tank to pump valve and the tank fill valve (C)</p> Signup and view all the answers

What is the maximum pressure that should be sent to any other truck during a relay pumping operation?

<p>100 PSI (A)</p> Signup and view all the answers

Which of the following is NOT a step in the Hydrant to Attack Engine (Less than 500 Feet) procedure?

<p>Attach a suction hose to the pump intake (C)</p> Signup and view all the answers

What is the purpose of using ball valves on the 2 1/2" hydrant discharges during a heavy hydrant hookup?

<p>To permit tapping more hydrant discharge GPM without interrupting water supply (A)</p> Signup and view all the answers

What is the role of the second arriving pumper in a relay pumping operation?

<p>To reverse lay from the attack pumper and communicate the needs to the third arriving pumper (C)</p> Signup and view all the answers

Why should drafting hose (corrugated) not be used on a hydrant?

<p>It can restrict water flow (B)</p> Signup and view all the answers

What should you do if no draft is established within 30 seconds when drafting through the piston intake valve?

<p>Check all connections and reattempt (C)</p> Signup and view all the answers

What is the recommended discharge pressure range to increase to when draft is established?

<p>50-100 psi (D)</p> Signup and view all the answers

What should be done to keep the strainer off the bottom of the static water supply?

<p>Attach a ladder to the drafting hose (A)</p> Signup and view all the answers

What operation should be avoided to prevent damage to the primer pump?

<p>Running the primer pump for more than 30 seconds (A)</p> Signup and view all the answers

What is a key factor in ensuring success during a water shuttle operation?

<p>Minimizing idle time of water shuttle apparatus (D)</p> Signup and view all the answers

What is the primary role of the attack pumper?

<p>To directly supply attack lines at the fire scene (B)</p> Signup and view all the answers

Which of the following is NOT a static water source?

<p>A fire hydrant (C)</p> Signup and view all the answers

What is the primary function of a relay pumper?

<p>To receive water from a source pumper or another relay pumper, boost the pressure, and supply water to the next apparatus in the relay (C)</p> Signup and view all the answers

What is the purpose of using large diameter hoses?

<p>To move large volumes of water over long distances (B)</p> Signup and view all the answers

What is a water shuttle operation?

<p>A method of water supply where tenders/tankers continuously transport water between a fill site and the dump site near the emergency scene (A)</p> Signup and view all the answers

What is the difference between a static source and a pressurized source?

<p>A static source is a body of water that needs to be drafted from, while a pressurized source is water under pressure in a supply piping system (B)</p> Signup and view all the answers

More Like This

330-02 Water Rescue
40 questions

330-02 Water Rescue

ComfyCarolingianArt avatar
ComfyCarolingianArt
Use Quizgecko on...
Browser
Browser