Fire Pumps
18 Questions
1 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

Which type of pumps are typically used as fire pumps?

  • Positive displacement pumps
  • Reciprocating pumps
  • Diaphragm pumps
  • Centrifugal pumps (correct)
  • What is the range of capacities for fire pumps?

  • 50 Lis to 500 Lis
  • 1.6 Lis to 300 Lis (correct)
  • 200 Lis to 2000 Lis
  • 100 Lis to 1000 Lis
  • Which standard must be met for the installation of fire pumps?

  • NFPA 20 (correct)
  • NFPA 40
  • NFPA 30
  • NFPA 10
  • Which of the following is a recommended check when a fire pump is not running?

    <p>Verify the fire pump inlet water pressure</p> Signup and view all the answers

    What is the purpose of a flow switch in a fire line?

    <p>To activate an alarm when there is a high fire water flow</p> Signup and view all the answers

    How often is regular fire pump testing mandated by NFPA 25?

    <p>Annually</p> Signup and view all the answers

    What should be checked shortly after start-up of a fire pump?

    <p>Suction and discharge pressures</p> Signup and view all the answers

    Which type of pump is used to pressurize the standpipe in the event of small leaks?

    <p>Jockey pump</p> Signup and view all the answers

    What initiates the start of a fire pump?

    <p>Pressure drop in the system</p> Signup and view all the answers

    What is the purpose of a jockey pump?

    <p>To maintain system pressure</p> Signup and view all the answers

    Which codes and standards must be met for pump drivers, auxiliary equipment, fuel storage systems, and associated electrical equipment?

    <p>All of the above</p> Signup and view all the answers

    Which system was incorporated into WHMIS 2015?

    <p>Globally Harmonized System (GHS)</p> Signup and view all the answers

    Who enforces the Transportation of Dangerous Goods (TDG) regulations?

    <p>Transport Canada</p> Signup and view all the answers

    When is fall protection equipment required to be worn?

    <p>At a height of 3 meters or more</p> Signup and view all the answers

    What is the main purpose of a fire safety plan?

    <p>To enhance and maintain the safety of a facility or plant</p> Signup and view all the answers

    Which of the following is considered a confined space according to the Canadian Occupational Health and Safety Regulations?

    <p>A space that may become hazardous due to its design or atmosphere</p> Signup and view all the answers

    Which of the following specialized safety trainings is usually provided by external certifying organizations?

    <p>Confined Space Entry (CSE)</p> Signup and view all the answers

    What are the key components of the Workplace Hazardous Materials Information System (WHMIS)?

    <p>Hazard classification, labeling requirements, safety data sheets (SDS), worker training and education programs</p> Signup and view all the answers