Fire Prevention Inspection Guidelines Quiz
40 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

Which of the following best describes how inspection area assignments are rotated?

  • Each platoon inspects each quadrant of the local alarm district once every three years.
  • Each platoon inspects each quadrant of the local alarm district once every four years. (correct)
  • Each platoon inspects each quadrant of the local alarm district once every two years.
  • Each platoon inspects each quadrant of the local alarm district once every five years.
  • What is the frequency of inspections for occupancies categorized as high hazard?

  • Inspected once every five years
  • Inspected every other year
  • Inspected once every three years
  • Inspected annually (correct)
  • Which of the following best describes the inspection frequency for occupancies categorized as low hazard?

  • Inspected once every three years
  • Inspected annually
  • Inspected every other year, based on the occupancy's address (correct)
  • Inspected once every five years
  • Which of the following is responsible for inspecting residential apartment/condo buildings?

    <p>The Operations Bureau</p> Signup and view all the answers

    When are building inspections conducted by the Operations Bureau?

    <p>Daily from March 1st through December 31st, excluding Sundays and holidays, from 0900 to 1700 hours</p> Signup and view all the answers

    What should the company do if permission to inspect the premises is denied?

    <p>Leave the premises and notify the Battalion Fire Inspector assigned to the area for follow-up</p> Signup and view all the answers

    Who is responsible for developing the Department's inspection program and training personnel on basic life safety inspection checks?

    <p>Fire Marshal</p> Signup and view all the answers

    What type of occupancy includes restaurants, bars, taverns, and night clubs?

    <p>Group 'A' Assembly Occupancy</p> Signup and view all the answers

    Which level of occupancy comprises professional or civic office buildings?

    <p>Group 'B' Business Occupancy</p> Signup and view all the answers

    What height qualifies a building as a high-rise according to the text?

    <p>Above 75 feet</p> Signup and view all the answers

    Which part of the Fire Department is responsible for initiating advanced enforcement actions for non-compliant properties?

    <p>Fire Inspectors</p> Signup and view all the answers

    Who ensures that companies under their command perform inspections and meet guidelines provided by the Fire Marshal?

    <p>Operational Battalion Fire Chiefs</p> Signup and view all the answers

    Which of the following responsibilities does the FPD Fire Inspector have?

    <p>All of the above</p> Signup and view all the answers

    What is the responsibility of the platoons in the Station Local Alarm Area Example?

    <p>All of the above</p> Signup and view all the answers

    What is the local alarm area for Engine Co. 1 according to the example?

    <p>K Street, NW to 18th Street, NW to Massachusetts Ave, NW to DuPont Circle to 21st Street, NW to 24th Street, NW to Wyoming Avenue, NW to Observatory Circle to 27th Street, NW to O Street, NW to M Street, NW to Key Bridge end at K Street, NW</p> Signup and view all the answers

    According to the Fire Code Violation References, which violation code section covers 'Hazards to Firefighters'?

    <p>IFC 316</p> Signup and view all the answers

    What does the Fire Code Violation References section state about 'Vertical shafts in buildings'?

    <p>Vertical shafts in buildings shall be properly marked and identified</p> Signup and view all the answers

    What is the requirement for the Fire Alarm System in terms of trouble signals on the annunciator panel?

    <p>No visible trouble signals</p> Signup and view all the answers

    What is the responsibility of the FPD Operations Captain?

    <p>To be the liaison between the FPD and the Operations Bureau for questions and communication on the Fire Prevention Inspection Program</p> Signup and view all the answers

    What is the correct maintenance schedule for the Kitchen Hood Suppression system?

    <p>Bi-annual servicing</p> Signup and view all the answers

    What is the purpose of an OS&Y Valve in a Fire-Sprinkler System?

    <p>To control water flow into the system</p> Signup and view all the answers

    What is the significance of the Knox Box mentioned in the text?

    <p>Houses spare keys for building access</p> Signup and view all the answers

    What does IFC 1008.1.9.3 specifically address regarding building exits?

    <p>Proper exit door signage installation</p> Signup and view all the answers

    According to the IFC regulations, what should be maintained at least 18 inches below all fire sprinklers?

    <p>Storage items</p> Signup and view all the answers

    How often should kitchen suppression systems be inspected and serviced?

    <p>Every six months</p> Signup and view all the answers

    What is the general guideline for the maximum distance to a fire extinguisher in a building?

    <p>Within 75 feet of all areas</p> Signup and view all the answers

    What is the minimum required clearance space around electrical portable heaters?

    <p>36 inches</p> Signup and view all the answers

    What is the minimum required clearance space around gas-fired heat-producing appliances?

    <p>3 feet</p> Signup and view all the answers

    What is the required clearance in front of electrical panels?

    <p>30 inches</p> Signup and view all the answers

    Which of the following is NOT allowed for permanent wiring?

    <p>Extension cords</p> Signup and view all the answers

    Where should oily rags or similar materials be stored?

    <p>In approved metal containers</p> Signup and view all the answers

    What is the requirement for combustible materials in the means of egress?

    <p>Combustible materials should not be stored in any portion of the means of egress</p> Signup and view all the answers

    Which of the following is NOT required for electrical receptacles?

    <p>Exposed electrical wiring is allowed</p> Signup and view all the answers

    What is the requirement for the use of extension cords?

    <p>Extension cords should not be used as permanent wiring, except for temporary power</p> Signup and view all the answers

    What is the purpose of the Fire Prevention Inspection Guidelines outlined in the text?

    <p>To establish policies and procedures for building inspections by the Fire Prevention Division and Operations Bureau members</p> Signup and view all the answers

    What is the purpose of dividing the company inspection routes into districts?

    <p>To distribute the inspection workload as equitably as possible among the companies</p> Signup and view all the answers

    What is the primary reference document cited in the text for the Fire Prevention Inspection Guidelines?

    <p>The Fire Code Supplement (12-H-DCMR) of the District of Columbia Construction Codes Supplement</p> Signup and view all the answers

    What is the responsibility of the Captains of Engine companies?

    <p>Both a and b</p> Signup and view all the answers

    What is the significance of the boundary lines for the company inspection districts?

    <p>The boundary lines shall run along the centerline of the roadway, unless otherwise stated</p> Signup and view all the answers

    What is the purpose of the ESO system mentioned in the text?

    <p>To provide a list of all buildings in the District, identified by the NFIRS property use code, Engine Company Local Alarm Area, and Battalion</p> Signup and view all the answers

    More Like This

    Fire Prevention Building Reports Quiz
    22 questions
    Water Leakage Prevention and Repair
    18 questions
    Incendio Prevention Chapter 2
    17 questions
    Building Safety and Prevention
    15 questions
    Use Quizgecko on...
    Browser
    Browser