What must all shop drawings contain as per the regulations?

  • The signature of a Type PL licensee, license number, installation date, and registration number (correct)
  • A stamped signature from any technician
  • Only the date of installation and the license number
  • The installation manual of the fire extinguisher system

Which of the following statements about the use of rubber stamps is true?

  • Rubber stamps can be used as long as they are in a specific size and format (correct)
  • Rubber stamps are allowed for signatures on shop drawings
  • Rubber stamps are completely prohibited for all forms of documentation
  • A stamped signature is considered acceptable if it includes the license number

What information is NOT required on the installation label for fixed fire extinguisher systems?

  • The signature and license number of the licensee
  • The firm's name, address, and telephone number
  • The manufacturer's warranty details (correct)
  • The date of installation

What is the required size for installation labels on fixed fire extinguisher systems?

<p>5 inches high by 4 inches wide (A)</p> Signup and view all the answers

Which of the following cannot be included on the installation label?

<p>The installation technician’s personal contact details (C)</p> Signup and view all the answers

What is one of the responsibilities of the commissioner in relation to fire safety?

<p>Adopt rules for the registration of firms involved in fire extinguisher systems. (B)</p> Signup and view all the answers

Which of the following is NOT a requirement the commissioner can impose?

<p>Restriction on the advertisement size for licensed firms. (C)</p> Signup and view all the answers

What must the commissioner adopt rules to regulate?

<p>The hydrostatic testing of fire extinguisher cylinders. (B)</p> Signup and view all the answers

What type of practices can the commissioner prohibit in advertising?

<p>False, misleading, or deceptive practices. (C)</p> Signup and view all the answers

In what scenario is the commissioner allowed to impose advertising restrictions?

<p>To stop false or deceptive advertising practices. (C)</p> Signup and view all the answers

Which of the following does the commissioner NOT restrict in the advertisement of licensed holders?

<p>Advertising through social media channels. (A)</p> Signup and view all the answers

The commissioner is responsible for which of the following actions?

<p>Certifying individuals to install fixed fire extinguisher systems. (B)</p> Signup and view all the answers

What is one requirement imposed on firms regarding fire extinguisher systems?

<p>They must register with the commissioner. (D)</p> Signup and view all the answers

What must new owners do to ensure the continuance of a business after a total change of ownership?

<p>Submit an application for a new certificate 14 days before the change (C)</p> Signup and view all the answers

When is a revised certificate required for a firm?

<p>When the firm changes its name, location, or mailing address (B)</p> Signup and view all the answers

What should a certificate holder do to replace a lost or destroyed certificate?

<p>Notify the state fire marshal and pay the required fee (D)</p> Signup and view all the answers

What happens to the expiration and renewal dates of branch office certificates?

<p>They expire and renew on the same date as the main office's certificate (C)</p> Signup and view all the answers

How long do certificate holders have to report a change of corporate officers?

<p>14 days after the change (D)</p> Signup and view all the answers

What is the nature of the certificates in terms of transferability?

<p>They are nontransferable either temporarily or permanently (D)</p> Signup and view all the answers

What is required for branch offices created prior to the rule's effective date regarding certificate expiration?

<p>They will align their expiration and renewal dates with the main office's certificate (D)</p> Signup and view all the answers

Which of the following describes type PL licenses?

<p>For planning, supervising, certifying, installing, or servicing of fixed systems other than pre-engineered systems (B)</p> Signup and view all the answers

What is the initial fee for a Certificate of Registration?

<p>$450 (A)</p> Signup and view all the answers

What is the late renewal fee for a registration expired between 1 to 90 days?

<p>$225 plus $50 for each branch (B)</p> Signup and view all the answers

What is the non-refundable fee for a duplicate certificate?

<p>$20 (D)</p> Signup and view all the answers

What is the renewal fee for Type A, B, and K Fire Extinguisher licenses for two years?

<p>$100 (D)</p> Signup and view all the answers

What is the initial fee for an Apprentice Permit?

<p>$30 (B)</p> Signup and view all the answers

Which fee applies for a late renewal after two years for a Certificate of Registration?

<p>$450 plus $100 for each branch (C)</p> Signup and view all the answers

What is the retest fee if administered by the SFMO?

<p>$20 (B)</p> Signup and view all the answers

What additional charge applies to late renewals for a registered firm with branch offices?

<p>$50 for each branch for 1 to 90 days late (D)</p> Signup and view all the answers

What is the maximum fee for an initial firm registration certificate?

<p>$450 (B)</p> Signup and view all the answers

Which of the following is NOT included in the duties of the department?

<p>Certifying private fire departments (B)</p> Signup and view all the answers

How often can a firm renew its registration certificate for installing or servicing portable fire extinguishers?

<p>Every year (C)</p> Signup and view all the answers

What is the fee for renewing an employee license annually?

<p>$50 (A)</p> Signup and view all the answers

Which type of certificate requires a fee of up to $100 for renewal?

<p>Branch office registration certificate (D)</p> Signup and view all the answers

What is the maximum fee for an apprentice permit?

<p>$30 (D)</p> Signup and view all the answers

Which service does the department NOT evaluate?

<p>Renewing employee licenses (C)</p> Signup and view all the answers

What is the maximum fee for the initial registration certificate to perform hydrostatic testing?

<p>$250 (C)</p> Signup and view all the answers

What must the fixed-temperature sensing elements of the fusible metal alloy type display when replaced in a kitchen hood fire extinguishing system?

<p>A manufacturer's date stamp within one year of replacement (B)</p> Signup and view all the answers

What is required for the disposable actuation cartridge when replaced in a kitchen hood fire extinguisher system?

<p>It must bear the date of replacement (C)</p> Signup and view all the answers

Which standard must pre-engineered dry chemical fixed fire extinguishing systems installed after January 1, 2006, meet?

<p>Underwriters Laboratories, Inc., Standard 1254 or a more recent edition (C)</p> Signup and view all the answers

What must be included on the service tag for new fusible links replaced in kitchen hood fire extinguishing systems?

<p>Year of manufacture, temperature, and quantity (D)</p> Signup and view all the answers

After maintaining a portable fire extinguisher, how must the new tamper seal be marked?

<p>With the year imprinted or embossed on the flag (A)</p> Signup and view all the answers

What must building firms maintain regarding fixed extinguisher systems protecting special hazards?

<p>Current shop drawings and hydraulic calculations for the life of the system (B)</p> Signup and view all the answers

What should happen if alterations or additions are made to an installed fire extinguishing system?

<p>They must be legibly noted on updated plans and provided to the owner (D)</p> Signup and view all the answers

What is NOT allowed for the date applied on the new tamper seal after maintaining a portable fire extinguisher?

<p>Marker-applied date (B)</p> Signup and view all the answers

Flashcards

Fire Suppression Regulations

The commissioner is responsible for establishing rules to ensure safety in the fire suppression industry.

Registration of Fire Suppression Firms

Companies involved in installing or servicing fire extinguishers must register with the commissioner.

Fire Suppression Technician Licensing

Individuals who install or service fire extinguishers must pass an exam and obtain a license.

Requirements for Fire Suppression Systems

The commissioner sets requirements for installing and servicing both portable and fixed fire systems.

Signup and view all the flashcards

Application and Qualification Process

The commissioner must set clear guidelines for the application and qualification process for various fire suppression licenses, permits, and certificates.

Signup and view all the flashcards

Restrictions on Advertising and Bidding

The commissioner may not create rules that restrict advertising or bids unless they are intended to prevent false, misleading, or deceptive practices.

Signup and view all the flashcards

Prohibited Restrictions on Advertising

Rules prohibiting false, misleading, or deceptive practices cannot restrict the use of specific advertising mediums, personal appearances, or specific ad parameters.

Signup and view all the flashcards

Trade Names in Advertising

Companies can advertise their fire suppression services under a trade name, even with restrictions on misleading ads in place.

Signup and view all the flashcards

Firm Qualification Evaluation

The process by which the Texas Department of Insurance evaluates a firm's qualifications to perform fire extinguisher installation, servicing, or testing.

Signup and view all the flashcards

Registration Certificate

A certificate authorizing a firm to operate in the business of installing or servicing portable or fixed fire extinguisher systems.

Signup and view all the flashcards

Testing Laboratory Approval

The approval granted to a testing laboratory that meets specific standards for fire extinguisher testing.

Signup and view all the flashcards

Issuance of Registration Certificates

The process by which the Texas Department of Insurance issues certifications to qualified firms.

Signup and view all the flashcards

Issuance of Licenses, Permits, and Authorizations

The process by which the Texas Department of Insurance issues licenses, apprentice permits, and authorizations to perform hydrostatic testing.

Signup and view all the flashcards

Initial Firm Registration Fee

The fee that must be paid to the Texas Department of Insurance for an initial firm registration certificate.

Signup and view all the flashcards

Annual Firm Registration Renewal Fee

The annual fee that must be paid to the Texas Department of Insurance to renew a firm registration certificate.

Signup and view all the flashcards

Annual Employee License Renewal Fee

The annual fee that must be paid to the Texas Department of Insurance to renew an employee license.

Signup and view all the flashcards

Branch office certificate of registration

A certificate that expires and renews on the same date as the main office's certificate.

Signup and view all the flashcards

Total change of ownership

The total change in ownership of a firm requires a new certificate of registration. This must be applied for 14 days before the change takes effect.

Signup and view all the flashcards

Partial change of ownership

A partial change in ownership that affects the name, location, or mailing address requires a revised certificate.

Signup and view all the flashcards

Change of corporate officers

Changes in a corporation's officers must be reported to the state fire marshal within 14 days. This change does not require a new or revised certificate.

Signup and view all the flashcards

Duplicate certificate

A replacement certificate that can be obtained from the state fire marshal if the original certificate is lost or destroyed.

Signup and view all the flashcards

Revised certificate

A certificate updated to reflect changes in the firm's name, location, or mailing address. It must be submitted within 14 days of the change.

Signup and view all the flashcards

Nontransferable certificate

A firm's certificate cannot be transferred to another firm, even temporarily.

Signup and view all the flashcards

Initial alignment of branch office certificate dates

Existing branch office certificates of registration will align their expiration and renewal dates to match the main office's certificate. Fees will be prorated accordingly.

Signup and view all the flashcards

Shop Drawing Requirements

Shop drawings for fire extinguisher systems must be signed by a licensed technician, including their license number, installation date, and the registered firm's certificate number.

Signup and view all the flashcards

Stamped Signatures

A rubber stamp can be used to provide the required information on shop drawings, but a stamped signature is not allowed.

Signup and view all the flashcards

Installation Label

After a fixed fire extinguisher system is installed, an installation label must be attached to the control panel or head.

Signup and view all the flashcards

Installation Label Content

The label certifies the system was installed according to regulations and must include specific information like the firm's details, licensee signature, installation date, and manufacturer's manual details.

Signup and view all the flashcards

Certificate of Installation

After installing, modifying, or adding to a fixed fire extinguisher system, a certificate of installation must be completed by the licensee in the format provided by the state fire marshal.

Signup and view all the flashcards

Initial Registration Fee

The initial cost for a Certificate of Registration, a document that allows businesses to operate in certain industries in Texas.

Signup and view all the flashcards

Renewal Fee

The fee charged for renewing a Certificate of Registration for two years.

Signup and view all the flashcards

Late Renewal Fee (Expired 1 Day to 90 Days)

Penalties assessed when a Certificate of Registration expires and is not renewed within 90 days, including a base fee and an additional fee for each branch office.

Signup and view all the flashcards

Late Renewal Fee (Expired 91 Days to Two Years)

A higher penalty charged when a Certificate of Registration expires and is not renewed within two years, including a base fee and an additional fee for each branch office.

Signup and view all the flashcards

Branch Office Initial Fee

The initial fee for establishing a branch office of a registered business.

Signup and view all the flashcards

Branch Office Renewal Fee

The fee to maintain a branch office for a period of two years.

Signup and view all the flashcards

Initial Test Fee

The fee charged for the initial test required for certain licenses, if administered by the State Fire Marshal's Office.

Signup and view all the flashcards

Retest Fee

The cost of retaking a test for a license if administered by the State Fire Marshal's Office.

Signup and view all the flashcards

Kitchen Hood Fusible Links

Servicing kitchen hood fire extinguishing systems requires replacement of fusible links within one year of manufacture date. Each link must include a manufacturer's date stamp and the system service tag should include the manufacturer's year, temperature, and quantity of replaced links.

Signup and view all the flashcards

Kitchen Hood Disposable Cartridge Date

When replacing disposable actuation cartridges in a kitchen hood system, the date of replacement must be clearly marked on the new cartridge.

Signup and view all the flashcards

Portable Extinguisher Tamper Seal

During portable fire extinguisher maintenance, a new tamper seal must be attached with the attachment year imprinted or embossed on the flag, not written with a marker.

Signup and view all the flashcards

Pre-engineered Dry Chemical Systems

New, remodeled, or relocated pre-engineered dry chemical fixed fire extinguishing systems must meet the minimum requirements of the second edition (1996) or a more recent edition of UL Standard 1254.

Signup and view all the flashcards

Combined Fire System Licensing

Installing or servicing a fixed fire extinguishing system that also involves parts of a fire alarm or detection system, or a fire sprinkler system (except for mechanical or pneumatic detection/actuation devices), requires satisfying the licensing requirements of Texas Insurance Code Chapters 6002 or 6003.

Signup and view all the flashcards

Fixed Fire System Plans

When a fixed fire extinguisher system for special hazards is installed, the company must provide shop drawings and hydraulic calculations to the building owner or their representative. They must also keep a copy of these documents for the life of the system.

Signup and view all the flashcards

Updated Fixed Fire System Plans

Any changes or additions to an existing fixed fire extinguisher system require updated plans to be provided to the owner. The firm must also keep these updated plans for the life of the system.

Signup and view all the flashcards

Fixed Fire System Plans for Special Hazards

When installing a fixed extinguisher system for special hazards, a set of shop drawings and hydraulic calculations detailing system piping, calculations, and alarm configurations must be provided to the building owner or their representative upon completion.

Signup and view all the flashcards

Study Notes

Fire Extinguisher Service and Installation

  • Governing Laws: Texas Insurance Code - Chapter 6001 and Texas Administrative Code - Section 34.500
  • Purpose: The chapter is to safeguard lives and property by regulating the leasing, selling, installation, and servicing of portable fire extinguishers, and planning, certifying, installing, and servicing fixed fire extinguisher systems. It also prohibits equipment not listed by an approved testing laboratory.
  • Definitions:
    • Firm: An individual, partnership, corporation, or association.
    • Fixed fire extinguisher system: An assembly of piping, conduits, or containers that convey liquid, powder, or gases to dispersal openings to suppress or extinguish fires.
    • Hydrostatic testing: Pressure testing by hydrostatic methods.
    • Insurance agent: An individual, firm, or corporation licensed under Subchapter E, Chapter 981; or Subchapter A, B, C, D, E or G, Chapter 4051; or an individual authorized to represent an insurance fund or pool created by a municipality, county, or other political subdivision.
    • Portable fire extinguisher: A device containing liquid, powder, or gases to suppress or extinguish fires.
    • Portable fire extinguisher inspection: A monthly inspection to ensure: the extinguisher is in its designated location, has not been tampered with, and has no obvious damage.
    • Service/servicing: Servicing a portable fire extinguisher or fixed system via charging, filling, maintaining, recharging, refilling, repairing, or testing.
    • Registered firm: A firm holding a registration certificate.

Subchapter B - Powers and Duties of Commissioner, Department, and State Fire Marshal

  • Administration of Chapter: The department administers the chapter. The commissioner may issue rules, determined necessary to administer the chapter.
  • Adoption of Rules: The Commissioner uses recognized standards, including those published by the NFPA, federal regulations, nationally recognized standards-making organizations, and manufacturer's installation manuals.
  • Rules Restricting Advertising or Competitive Bidding: The commissioner may not restrict advertising usage, personal appearance of the holder, size or duration of an advertisement, or restrict advertisements under a trade name.
  • General Powers and Duties of Department: The department evaluates the qualifications of firms seeking to be registered to install/service portable fire extinguishers or fixed systems, or seeking approval as a testing laboratory. They issue registration certificates for these firms and licenses for individuals and groups.

Subchapter D - Registration, License, and Permit Requirements

  • Firm Registration Certificate: Required for firms engaging in the installation/service of portable extinguishers or fixed systems.
  • Branch Office Registration: Required for each separate office location, must be part of a registered firm.
  • Hydrostatic Testing: Certificates required before performing hydrostatic testing, in alignment with U.S. DOT specs.
  • Required Insurance Coverage: Evidence of general liability insurance is necessary with minimum coverage for bodily injury and property damage per occurrence, and aggregate amounts.
  • Employee Licensing: Required for installing/servicing portable extinguishers or fixed systems (excluding apprentices)
  • Apprentice Permit: Required for activities as an apprentice.

Subchapter E - Renewal of Registration, License, or Permit

  • Renewal Required: Registration certificates/licenses are valid for two years, with renewal fees payable on a per-year basis.
  • Notice of Expiration: Written notice of the expiration date is given 30 days prior to expiry.
  • Renewal Procedures: Renewal fees are payable prior to the expiration date. There's a fee for renewal if a registration certificate or license has been expired for over 90 days or two years, and it depends on the number of days expired.