Podcast
Questions and Answers
What is the recommended distance from the hoseline(s) supplying the FDC that all personnel operating at the incident and civilians should be removed from?
What is the recommended distance from the hoseline(s) supplying the FDC that all personnel operating at the incident and civilians should be removed from?
How should the lines supplying the FDC be secured to relieve pressure from the coupling?
How should the lines supplying the FDC be secured to relieve pressure from the coupling?
Where should the supply and discharge lines be connected to the engine?
Where should the supply and discharge lines be connected to the engine?
Why should personnel in the stairwells where standpipes are under high pressure be kept to a minimum?
Why should personnel in the stairwells where standpipes are under high pressure be kept to a minimum?
Signup and view all the answers
What should be done when operating hand line and floor outlet valves?
What should be done when operating hand line and floor outlet valves?
Signup and view all the answers
In the context of high-pressure pumping, what is the purpose of using warning/caution tape and/or traffic cones?
In the context of high-pressure pumping, what is the purpose of using warning/caution tape and/or traffic cones?
Signup and view all the answers
What action should be taken if the configuration of the incident scene makes it impractical to use warning/caution tape and/or traffic cones?
What action should be taken if the configuration of the incident scene makes it impractical to use warning/caution tape and/or traffic cones?
Signup and view all the answers
What is the minimum recommended distance for securing the lines supplying the FDC to relieve pressure from the coupling?
What is the minimum recommended distance for securing the lines supplying the FDC to relieve pressure from the coupling?
Signup and view all the answers
Why should the operation of hand line and floor outlet valves be done slowly?
Why should the operation of hand line and floor outlet valves be done slowly?
Signup and view all the answers
What is the standard operating procedure regarding the priority of Fire Department Connections (FDC)?
What is the standard operating procedure regarding the priority of Fire Department Connections (FDC)?
Signup and view all the answers
What type of line is used to supply Fire Department Connections (FDC) for sprinklers?
What type of line is used to supply Fire Department Connections (FDC) for sprinklers?
Signup and view all the answers
Under what circumstance can a standpipe outlet on the interior effectively supply a sprinkler system?
Under what circumstance can a standpipe outlet on the interior effectively supply a sprinkler system?
Signup and view all the answers
What is the recommended action regarding Pressure Regulating Devices (PRDs) during a fire incident?
What is the recommended action regarding Pressure Regulating Devices (PRDs) during a fire incident?
Signup and view all the answers
What does an outside water flow alarm/motor gong operating indicate?
What does an outside water flow alarm/motor gong operating indicate?
Signup and view all the answers
What should be done upon determining a fire is under control regarding the sprinkler system for the affected area?
What should be done upon determining a fire is under control regarding the sprinkler system for the affected area?
Signup and view all the answers
Who should be contacted when the sprinkler system has operated, according to the standard operating procedure?
Who should be contacted when the sprinkler system has operated, according to the standard operating procedure?
Signup and view all the answers
What should the Incident Commander determine if the sprinkler system cannot be fully restored?
What should the Incident Commander determine if the sprinkler system cannot be fully restored?
Signup and view all the answers
What are ladder company sprinkler kits equipped with?
What are ladder company sprinkler kits equipped with?
Signup and view all the answers
What is the purpose of SOP 2?
What is the purpose of SOP 2?
Signup and view all the answers
What does SOP 2 state about the conflict between SOP 1 and SOP 2?
What does SOP 2 state about the conflict between SOP 1 and SOP 2?
Signup and view all the answers
What is a Combination System as defined in SOP 2?
What is a Combination System as defined in SOP 2?
Signup and view all the answers
What is a Pressure Restricting Regulating Device (PRD) according to SOP 2?
What is a Pressure Restricting Regulating Device (PRD) according to SOP 2?
Signup and view all the answers
What is the recommended positioning for engine companies when responding to structures with water-based fire protection systems?
What is the recommended positioning for engine companies when responding to structures with water-based fire protection systems?
Signup and view all the answers
What should engine companies supplying FDCs attempt to do with the positioning of the apparatus?
What should engine companies supplying FDCs attempt to do with the positioning of the apparatus?
Signup and view all the answers
What should engine companies do when a structure has more than one FDC available?
What should engine companies do when a structure has more than one FDC available?
Signup and view all the answers
Study Notes
Fire Department Connections, Sprinklers, and Standpipes Standard Operating Procedures
- Fire Department Connections (FDC) for sprinklers take priority over FDC for standpipes, unless directed by the Incident Commander
- A three-inch high-pressure line (blue) is used to supply FDCs, as a four-inch supply line cannot accommodate the required working pressure
- If the FDC on the building exterior is damaged, a system may be supplied via a standpipe outlet on the interior, but it may not effectively supply a sprinkler system unless part of a combination system
- Pressure Regulating Devices (PRDs) should be removed or disabled if possible, unless directed by the Incident Commander
- Sprinkler system pump pressure is 150 psi + 5 psi per floor
- An outside water flow alarm/motor gong operating may indicate water flow in the system
- Different levels of steam, smoke, and fire indicate the status of the sprinkler system and fire control
- Upon determining a fire is under control, the sprinkler system for the affected area should be temporarily shut down using applicable sectional valves
- The Incident Commander should contact the building owner or representative and the fire alarm company when the sprinkler system has operated
- The Incident Commander should determine if a building representative or sprinkler service company can install new sprinkler heads or establish a fire watch if the system cannot be fully restored
- Ladder company sprinkler kits are equipped with specific tools to minimize water damage and should not carry sprinkler heads
- Each engine is equipped with a standpipe kit for standpipe operations and firefighting at heights and distances beyond standard capabilities
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
Test your knowledge of Fire Department Connections (FDC), sprinkler systems, and standpipes with this quiz on standard operating procedures. Brush up on important protocols and best practices for handling these critical firefighting equipment and systems.