Questions and Answers
What is G-60?
What are torch operations for jewelry referred to as?
COF exception
What type of permit is required for storing, using, or handling oxygen and flammable gas in excess of 400 SCF?
FDNY permit
What is the maximum capacity for portable LPG containers?
Signup and view all the answers
What is the maximum capacity for portable CNG containers?
Signup and view all the answers
What is the maximum weight for single standard portable LPG containers?
Signup and view all the answers
What is the maximum capacity for single CNG containers?
Signup and view all the answers
What is approximately 400 SCF of LPG in pounds?
Signup and view all the answers
What are the types of FDNY permits?
Signup and view all the answers
What can site specific permits be?
Signup and view all the answers
How long are permanent permits valid?
Signup and view all the answers
How long might temporary permits be valid?
Signup and view all the answers
What is the duration for citywide permits?
Signup and view all the answers
What is the maximum quantity of gasoline that can be stored?
Signup and view all the answers
What is the maximum quantity of flammable liquid that can be stored?
Signup and view all the answers
What is the maximum quantity for combustible liquids stored?
Signup and view all the answers
What characterizes a transportation permit?
Signup and view all the answers
What is required for any project with hot work operations?
Signup and view all the answers
Who must be available for inspection during and after the hot work?
Signup and view all the answers
What does a fire guard do?
Signup and view all the answers
What must a fire watch include?
Signup and view all the answers
How often must a pre-hot work check be conducted?
Signup and view all the answers
What should daily pre-hot work checks verify?
Signup and view all the answers
How long must fire watch continue after work is done?
Signup and view all the answers
What is the inspection report availability period after work is completed?
Signup and view all the answers
What materials are oxygen cylinders typically made of?
Signup and view all the answers
What is the temperature generated by oxy-propane torches?
Signup and view all the answers
What is the temperature generated by acetylene?
Signup and view all the answers
What is the maximum temperature generated by oxy-acetylene?
Signup and view all the answers
What temperature is typically achieved by brazing and soldering?
Signup and view all the answers
What is the pressure up to which oxy-fuel torches store oxygen?
Signup and view all the answers
What pressure is dangerous for acetylene fuel gas?
Signup and view all the answers
What are applications and additions for gas torches?
Signup and view all the answers
What is backfire?
Signup and view all the answers
What is flashback?
Signup and view all the answers
What type of clothing should be avoided during hot work?
Signup and view all the answers
What temperatures are dangerous for compression gas containers?
Signup and view all the answers
What is the most important part of compressed gas systems?
Signup and view all the answers
What is a fire guard?
Signup and view all the answers
What is the purpose of a fire watch?
Signup and view all the answers
What operations are covered by hot work?
Signup and view all the answers
What constitutes a hot work area?
Signup and view all the answers
What does NFPA stand for?
Signup and view all the answers
What is personal supervision in regards to hot work?
Signup and view all the answers
Who designates the responsible person for fire safety at a hot work site?
Signup and view all the answers
What type of roofing systems are torch-applied?
Signup and view all the answers
What do oxygen-fuel gas torches consist of?
Signup and view all the answers
What is the purpose of mixing oxygen and fuel gas in the torch?
Signup and view all the answers
What does oxygen do in combustion?
Signup and view all the answers
How much higher is the temperature produced by oxy-propane compared to air-propane?
Signup and view all the answers
Why is acetylene commonly used?
Signup and view all the answers
Where are control valves located on gas containers?
Signup and view all the answers
What do the valves on gas containers control?
Signup and view all the answers
What feature do gas containers have for safety?
Signup and view all the answers
What should be done when cylinders are not in use?
Signup and view all the answers
At what pressure is oxygen stored in cylinders?
Signup and view all the answers
What is the purpose of storing fuel gas at higher pressures?
Signup and view all the answers
What is dangerous when using fuel gas?
Signup and view all the answers
What does the regulator do in a gas system?
Signup and view all the answers
What gases are mixed inside the torch?
Signup and view all the answers
What does adjusting the valves control?
Signup and view all the answers
What does welding involve?
Signup and view all the answers
What do cutting processes involve?
Signup and view all the answers
What do both welding and cutting processes often include?
Signup and view all the answers
What is the highest temperature generated by oxy-acetylene?
Signup and view all the answers
Where must the Certificate of Fitness be kept?
Signup and view all the answers
What should portable LPG containers not exceed for indoors storage?
Signup and view all the answers
Where must permits be made available for inspection?
Signup and view all the answers
How long after work is complete must hot work permits be available for inspection?
Signup and view all the answers
What must the citywide permit holder do before starting operations?
Signup and view all the answers
When must pre-hot work checks be conducted?
Signup and view all the answers
For how long must fire watch be provided after work is complete?
Signup and view all the answers
How far must hot work areas be kept from combustible material?
Signup and view all the answers
What are examples of combustible materials?
Signup and view all the answers
What should be checked in the entire work area after hot work is completed?
Signup and view all the answers
What is the minimum rating for a fire extinguisher that must be readily accessible?
Signup and view all the answers
How far must a fire extinguisher be accessible from the hot work location?
Signup and view all the answers
What minimum rating must a fire extinguisher have for torch-applied roof systems?
Signup and view all the answers
What type of protection system must not be turned off during hot work?
Signup and view all the answers
When must compressed gas containers be replaced?
Signup and view all the answers
How should empty containers be handled?
Signup and view all the answers
How should compressed gas containers not be transported?
Signup and view all the answers
What are the required height restrictions for fire extinguishers?
Signup and view all the answers
When should a COF holder consider extinguishing fires?
Signup and view all the answers
What direction should one never approach a fire from?
Signup and view all the answers
Where should the chemical stream not be directed at a fire?
Signup and view all the answers
What should be done first in the case of piped gas emergencies?
Signup and view all the answers
What to do when it is not possible to shut off the gas supply?
Signup and view all the answers
What are Class A extinguishers used for?
Signup and view all the answers
What are Class B extinguishers used for?
Signup and view all the answers
What are Class C extinguishers used for?
Signup and view all the answers
What are Class D extinguishers used for?
Signup and view all the answers
How often are fire extinguishers required to be inspected?
Signup and view all the answers
How often must fire extinguishers be maintained by an FDNY approved company?
Signup and view all the answers
Where should fire watch for torch operations be conducted?
Signup and view all the answers
Study Notes
G-60 and F-60 Fire Guard Overview
- G-60 pertains to hot work operations using oxygen and flammable gases like LPG or CNG.
- Exceptions include COF for torch operations in jewelry.
FDNY Permits and Regulations
- A FDNY permit is required when storing, using, or handling more than 400 scf of oxygen or flammable gases and over 504 scf of oxidizing gas.
- Types of permits include site-specific, citywide, and transportation permits.
- Site-specific permits can be permanent or temporary, valid for up to 12 months.
- Citywide permits last 30 days; temporary permits range from one day to 12 months, depending on operations.
Hazardous Material Storage
- Maximum storage quantities for hazardous materials are 5 gallons of gasoline, 250 gallons of flammable liquids, and 300 gallons of combustible liquids.
Hot Work and Fire Watch Procedures
- Hot work requires pre-hot work checks conducted daily by a responsible person.
- A fire watch must be maintained before, during, and for 30 minutes after hot work.
- Fire extinguishers must be accessible within 30 feet of the hot work area and must meet minimum rating requirements (2-A:20-B:C, 3-A:40-B:C for roofing).
Equipment and Safety Protocols
- Oxygen cylinders are made of steel and store oxygen at pressures up to 2200 PSI.
- Oxy-acetylene torches can reach temperatures up to 6000 degrees Fahrenheit; oxy-propane torches reach about 1500 degrees Fahrenheit.
- hazardous conditions include frayed clothing, which is more susceptible to ignition.
Emergency and Fire Extinguishing Procedures
- Classes of fire extinguishers are classified as A, B, C, and D for ordinary combustibles, flammable liquids, electrical equipment, and ignitable metals, respectively.
- Fire extinguishers must be inspected monthly and maintained by an FDNY-approved company annually.
- In case of a gas leak, shut off the gas supply before calling 911, or allow the flame to burn out if it’s unsafe to shut the supply.
Responsibilities of Personnel
- The responsible person must be available for inspection by fire department representatives for 48 hours after completion of the work.
- Fire guards are trained personnel who maintain fire watch during hot work operations and ensure safety protocols are followed.
- A COF holder must keep the Certificate of Fitness on their person or readily available for inspection.
Inspection and Maintenance
- Inspections of CNG or LPG torch operations are conducted 30 minutes and one hour after completion.
- The inspection report must be available for fire department representatives within 48 hours after work is complete.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
Explore essential definitions and concepts related to the F-60 Fire Guard certification. This study material will help candidates understand critical terms like G-60, COF exceptions, and FDNY permits related to hot work involving flammable gases. Prepare effectively for your examination with these comprehensive flashcards.