Podcast
Questions and Answers
What is G-60?
What is G-60?
- A fire safety code
- A type of fire extinguishing system
- A certificate for fire safety
- Use of oxygen and flammable gases for any hot work (correct)
What are torch operations for jewelry referred to as?
What are torch operations for jewelry referred to as?
COF exception
What type of permit is required for storing, using, or handling oxygen and flammable gas in excess of 400 SCF?
What type of permit is required for storing, using, or handling oxygen and flammable gas in excess of 400 SCF?
FDNY permit
What is the maximum capacity for portable LPG containers?
What is the maximum capacity for portable LPG containers?
What is the maximum capacity for portable CNG containers?
What is the maximum capacity for portable CNG containers?
What is the maximum weight for single standard portable LPG containers?
What is the maximum weight for single standard portable LPG containers?
What is the maximum capacity for single CNG containers?
What is the maximum capacity for single CNG containers?
What is approximately 400 SCF of LPG in pounds?
What is approximately 400 SCF of LPG in pounds?
What are the types of FDNY permits?
What are the types of FDNY permits?
What can site specific permits be?
What can site specific permits be?
How long are permanent permits valid?
How long are permanent permits valid?
How long might temporary permits be valid?
How long might temporary permits be valid?
What is the duration for citywide permits?
What is the duration for citywide permits?
What is the maximum quantity of gasoline that can be stored?
What is the maximum quantity of gasoline that can be stored?
What is the maximum quantity of flammable liquid that can be stored?
What is the maximum quantity of flammable liquid that can be stored?
What is the maximum quantity for combustible liquids stored?
What is the maximum quantity for combustible liquids stored?
What characterizes a transportation permit?
What characterizes a transportation permit?
What is required for any project with hot work operations?
What is required for any project with hot work operations?
Who must be available for inspection during and after the hot work?
Who must be available for inspection during and after the hot work?
What does a fire guard do?
What does a fire guard do?
What must a fire watch include?
What must a fire watch include?
How often must a pre-hot work check be conducted?
How often must a pre-hot work check be conducted?
What should daily pre-hot work checks verify?
What should daily pre-hot work checks verify?
How long must fire watch continue after work is done?
How long must fire watch continue after work is done?
What is the inspection report availability period after work is completed?
What is the inspection report availability period after work is completed?
What materials are oxygen cylinders typically made of?
What materials are oxygen cylinders typically made of?
What is the temperature generated by oxy-propane torches?
What is the temperature generated by oxy-propane torches?
What is the temperature generated by acetylene?
What is the temperature generated by acetylene?
What is the maximum temperature generated by oxy-acetylene?
What is the maximum temperature generated by oxy-acetylene?
What temperature is typically achieved by brazing and soldering?
What temperature is typically achieved by brazing and soldering?
What is the pressure up to which oxy-fuel torches store oxygen?
What is the pressure up to which oxy-fuel torches store oxygen?
What pressure is dangerous for acetylene fuel gas?
What pressure is dangerous for acetylene fuel gas?
What are applications and additions for gas torches?
What are applications and additions for gas torches?
What is backfire?
What is backfire?
What is flashback?
What is flashback?
What type of clothing should be avoided during hot work?
What type of clothing should be avoided during hot work?
What temperatures are dangerous for compression gas containers?
What temperatures are dangerous for compression gas containers?
What is the most important part of compressed gas systems?
What is the most important part of compressed gas systems?
What is a fire guard?
What is a fire guard?
What is the purpose of a fire watch?
What is the purpose of a fire watch?
What operations are covered by hot work?
What operations are covered by hot work?
What constitutes a hot work area?
What constitutes a hot work area?
What does NFPA stand for?
What does NFPA stand for?
What is personal supervision in regards to hot work?
What is personal supervision in regards to hot work?
Who designates the responsible person for fire safety at a hot work site?
Who designates the responsible person for fire safety at a hot work site?
What type of roofing systems are torch-applied?
What type of roofing systems are torch-applied?
What do oxygen-fuel gas torches consist of?
What do oxygen-fuel gas torches consist of?
What is the purpose of mixing oxygen and fuel gas in the torch?
What is the purpose of mixing oxygen and fuel gas in the torch?
What does oxygen do in combustion?
What does oxygen do in combustion?
How much higher is the temperature produced by oxy-propane compared to air-propane?
How much higher is the temperature produced by oxy-propane compared to air-propane?
Why is acetylene commonly used?
Why is acetylene commonly used?
Where are control valves located on gas containers?
Where are control valves located on gas containers?
What do the valves on gas containers control?
What do the valves on gas containers control?
What feature do gas containers have for safety?
What feature do gas containers have for safety?
What should be done when cylinders are not in use?
What should be done when cylinders are not in use?
At what pressure is oxygen stored in cylinders?
At what pressure is oxygen stored in cylinders?
What is the purpose of storing fuel gas at higher pressures?
What is the purpose of storing fuel gas at higher pressures?
What is dangerous when using fuel gas?
What is dangerous when using fuel gas?
What does the regulator do in a gas system?
What does the regulator do in a gas system?
What gases are mixed inside the torch?
What gases are mixed inside the torch?
What does adjusting the valves control?
What does adjusting the valves control?
What does welding involve?
What does welding involve?
What do cutting processes involve?
What do cutting processes involve?
What do both welding and cutting processes often include?
What do both welding and cutting processes often include?
What is the highest temperature generated by oxy-acetylene?
What is the highest temperature generated by oxy-acetylene?
Where must the Certificate of Fitness be kept?
Where must the Certificate of Fitness be kept?
What should portable LPG containers not exceed for indoors storage?
What should portable LPG containers not exceed for indoors storage?
Where must permits be made available for inspection?
Where must permits be made available for inspection?
How long after work is complete must hot work permits be available for inspection?
How long after work is complete must hot work permits be available for inspection?
What must the citywide permit holder do before starting operations?
What must the citywide permit holder do before starting operations?
When must pre-hot work checks be conducted?
When must pre-hot work checks be conducted?
For how long must fire watch be provided after work is complete?
For how long must fire watch be provided after work is complete?
How far must hot work areas be kept from combustible material?
How far must hot work areas be kept from combustible material?
What are examples of combustible materials?
What are examples of combustible materials?
What should be checked in the entire work area after hot work is completed?
What should be checked in the entire work area after hot work is completed?
What is the minimum rating for a fire extinguisher that must be readily accessible?
What is the minimum rating for a fire extinguisher that must be readily accessible?
How far must a fire extinguisher be accessible from the hot work location?
How far must a fire extinguisher be accessible from the hot work location?
What minimum rating must a fire extinguisher have for torch-applied roof systems?
What minimum rating must a fire extinguisher have for torch-applied roof systems?
What type of protection system must not be turned off during hot work?
What type of protection system must not be turned off during hot work?
When must compressed gas containers be replaced?
When must compressed gas containers be replaced?
How should empty containers be handled?
How should empty containers be handled?
How should compressed gas containers not be transported?
How should compressed gas containers not be transported?
What are the required height restrictions for fire extinguishers?
What are the required height restrictions for fire extinguishers?
When should a COF holder consider extinguishing fires?
When should a COF holder consider extinguishing fires?
What direction should one never approach a fire from?
What direction should one never approach a fire from?
Where should the chemical stream not be directed at a fire?
Where should the chemical stream not be directed at a fire?
What should be done first in the case of piped gas emergencies?
What should be done first in the case of piped gas emergencies?
What to do when it is not possible to shut off the gas supply?
What to do when it is not possible to shut off the gas supply?
What are Class A extinguishers used for?
What are Class A extinguishers used for?
What are Class B extinguishers used for?
What are Class B extinguishers used for?
What are Class C extinguishers used for?
What are Class C extinguishers used for?
What are Class D extinguishers used for?
What are Class D extinguishers used for?
How often are fire extinguishers required to be inspected?
How often are fire extinguishers required to be inspected?
How often must fire extinguishers be maintained by an FDNY approved company?
How often must fire extinguishers be maintained by an FDNY approved company?
Where should fire watch for torch operations be conducted?
Where should fire watch for torch operations be conducted?
Study Notes
G-60 and F-60 Fire Guard Overview
- G-60 pertains to hot work operations using oxygen and flammable gases like LPG or CNG.
- Exceptions include COF for torch operations in jewelry.
FDNY Permits and Regulations
- A FDNY permit is required when storing, using, or handling more than 400 scf of oxygen or flammable gases and over 504 scf of oxidizing gas.
- Types of permits include site-specific, citywide, and transportation permits.
- Site-specific permits can be permanent or temporary, valid for up to 12 months.
- Citywide permits last 30 days; temporary permits range from one day to 12 months, depending on operations.
Hazardous Material Storage
- Maximum storage quantities for hazardous materials are 5 gallons of gasoline, 250 gallons of flammable liquids, and 300 gallons of combustible liquids.
Hot Work and Fire Watch Procedures
- Hot work requires pre-hot work checks conducted daily by a responsible person.
- A fire watch must be maintained before, during, and for 30 minutes after hot work.
- Fire extinguishers must be accessible within 30 feet of the hot work area and must meet minimum rating requirements (2-A:20-B:C, 3-A:40-B:C for roofing).
Equipment and Safety Protocols
- Oxygen cylinders are made of steel and store oxygen at pressures up to 2200 PSI.
- Oxy-acetylene torches can reach temperatures up to 6000 degrees Fahrenheit; oxy-propane torches reach about 1500 degrees Fahrenheit.
- hazardous conditions include frayed clothing, which is more susceptible to ignition.
Emergency and Fire Extinguishing Procedures
- Classes of fire extinguishers are classified as A, B, C, and D for ordinary combustibles, flammable liquids, electrical equipment, and ignitable metals, respectively.
- Fire extinguishers must be inspected monthly and maintained by an FDNY-approved company annually.
- In case of a gas leak, shut off the gas supply before calling 911, or allow the flame to burn out if it’s unsafe to shut the supply.
Responsibilities of Personnel
- The responsible person must be available for inspection by fire department representatives for 48 hours after completion of the work.
- Fire guards are trained personnel who maintain fire watch during hot work operations and ensure safety protocols are followed.
- A COF holder must keep the Certificate of Fitness on their person or readily available for inspection.
Inspection and Maintenance
- Inspections of CNG or LPG torch operations are conducted 30 minutes and one hour after completion.
- The inspection report must be available for fire department representatives within 48 hours after work is complete.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
Explore essential definitions and concepts related to the F-60 Fire Guard certification. This study material will help candidates understand critical terms like G-60, COF exceptions, and FDNY permits related to hot work involving flammable gases. Prepare effectively for your examination with these comprehensive flashcards.