Podcast
Questions and Answers
What does the FDC pump operator need to do to ensure the appropriate amount of pressure makes it past the PRVs on the fire floor?
What does the FDC pump operator need to do to ensure the appropriate amount of pressure makes it past the PRVs on the fire floor?
- Rely on the building's internal clappers to deliver water into the building
- Increase pressure until a residual pressure drop is seen on the master intake gauge
- Ignore the flow meter portion of the gauge if it is not working
- Determine the pressure needed at the top floor and supply that pressure to the building (correct)
What action indicates to the pump operator that they have overcome the clapper valve and have started moving water into the building?
What action indicates to the pump operator that they have overcome the clapper valve and have started moving water into the building?
- Seeing flow in the red numbers on the outlet gauge (correct)
- Seeing a residual pressure drop on the master intake gauge
- Connecting a large gated wye to the standpipe outlet
- Using an elevated waterway for supplying water
What is the purpose of using a first-floor standpipe outlet as an inlet if the FDC is damaged or missing?
What is the purpose of using a first-floor standpipe outlet as an inlet if the FDC is damaged or missing?
- To allow water to flow into the standpipe even if it has a PRV
- To use an elevated waterway for supplying water
- To connect a large gated wye to the standpipe outlet
- To deliver water to the building when alternate methods are needed (correct)
How can firefighters differentiate between a test head discharge and an FDC?
How can firefighters differentiate between a test head discharge and an FDC?
When is an elevated waterway used as an alternate method for delivering water to the building?
When is an elevated waterway used as an alternate method for delivering water to the building?
What should the first arriving medic crew do if no victims are present or expected?
What should the first arriving medic crew do if no victims are present or expected?
What should be set up at ground level when the first EMS supervisor arrives?
What should be set up at ground level when the first EMS supervisor arrives?
What does the first arriving battalion chief do at a high-rise incident?
What does the first arriving battalion chief do at a high-rise incident?
What is the purpose of Phase I in elevator operation during a fire emergency?
What is the purpose of Phase I in elevator operation during a fire emergency?
During Phase II operation in an elevator during a fire emergency, what does holding the door open button until the doors are completely open indicate?
During Phase II operation in an elevator during a fire emergency, what does holding the door open button until the doors are completely open indicate?
What should firefighters do if the Phase II firefighter helmet light in the car is flashing during elevator operation in a fire emergency?
What should firefighters do if the Phase II firefighter helmet light in the car is flashing during elevator operation in a fire emergency?
What is the recommended maximum number of firefighters to be accommodated in an elevator car during a fire emergency?
What is the recommended maximum number of firefighters to be accommodated in an elevator car during a fire emergency?
What should be done to ensure Phase I is activated and recall the car to the lobby for next arriving crews to use?
What should be done to ensure Phase I is activated and recall the car to the lobby for next arriving crews to use?
Why should firefighters back into the elevator cars when loading during a fire emergency?
Why should firefighters back into the elevator cars when loading during a fire emergency?
What is the purpose of stopping at every five floors during elevator operation in a fire emergency?
What is the purpose of stopping at every five floors during elevator operation in a fire emergency?
What should be done if there is no firefighter service or recall function for an elevator during a fire emergency?
What should be done if there is no firefighter service or recall function for an elevator during a fire emergency?
Why should elevators that do not service the fire floor be chosen if possible during firefighting operations?
Why should elevators that do not service the fire floor be chosen if possible during firefighting operations?
What is a critical job assigned to Lobby Control Group during firefighting operations?
What is a critical job assigned to Lobby Control Group during firefighting operations?
Why is it important for Group supervisors to get a set of master keys during firefighting operations?
Why is it important for Group supervisors to get a set of master keys during firefighting operations?
What is the responsibility of the ladder driver upon arrival at the scene?
What is the responsibility of the ladder driver upon arrival at the scene?
What should be done if the swivel of the FDC is frozen in place?
What should be done if the swivel of the FDC is frozen in place?
What pressure load sharing mechanism is used between two CFD engines at the FDC?
What pressure load sharing mechanism is used between two CFD engines at the FDC?
What is the purpose of removing all the plugs from the FDC prior to pumping water?
What is the purpose of removing all the plugs from the FDC prior to pumping water?
When should the FDC engine increase pump pressure according to the text?
When should the FDC engine increase pump pressure according to the text?
What is the generic pump discharge pressure required for a dry system according to the text?
What is the generic pump discharge pressure required for a dry system according to the text?
What should be done if a member from the Lobby Control Group needs to check if the pump is running during high-rise fire operations?
What should be done if a member from the Lobby Control Group needs to check if the pump is running during high-rise fire operations?
What should be done if PRVs on standpipes are present in a building and the fire pump fails?
What should be done if PRVs on standpipes are present in a building and the fire pump fails?
What kind of buildings require $100 PSI residual pressure at the most remote outlet from the pump while flowing 500 GPM?
What kind of buildings require $100 PSI residual pressure at the most remote outlet from the pump while flowing 500 GPM?
What is used to remove debris inside the FDC according to the text?
What is used to remove debris inside the FDC according to the text?
'If firefighters deliver water to two inlets and later decide to supply additional FDC inlets, failing to remove all the plugs initially can cause what?'
'If firefighters deliver water to two inlets and later decide to supply additional FDC inlets, failing to remove all the plugs initially can cause what?'
According to the text, what is used by CFD engines for intake relief valve when pumping operations involve pressures above 180 PSI?
According to the text, what is used by CFD engines for intake relief valve when pumping operations involve pressures above 180 PSI?
What is a drawback of the lobby command post?
What is a drawback of the lobby command post?
What is the purpose of the Digital Vehicular Repeater System (DVRS) carried on Battalion Chief and SO-2 vehicles?
What is the purpose of the Digital Vehicular Repeater System (DVRS) carried on Battalion Chief and SO-2 vehicles?
What does the Local Mode of DVRS function as?
What does the Local Mode of DVRS function as?
Why are high-rise buildings more challenging for communication during a fire?
Why are high-rise buildings more challenging for communication during a fire?
What is one advantage of the exterior command post?
What is one advantage of the exterior command post?
Which mode of DVRS is utilized to boost radio signals?
Which mode of DVRS is utilized to boost radio signals?
What is the main function of DVRS carried on Battalion Chief and SO-2 vehicles?
What is the main function of DVRS carried on Battalion Chief and SO-2 vehicles?
Why is it desirable to have an exterior command post?
Why is it desirable to have an exterior command post?
What is the appropriate action for crews if the fire floor is within walking distance?
What is the appropriate action for crews if the fire floor is within walking distance?
What is the responsibility of the FDC pump operator to ensure proper water pressure on the fire floor?
What is the responsibility of the FDC pump operator to ensure proper water pressure on the fire floor?
What should be done if the fire is out of walking distance and the elevators have firefighter service?
What should be done if the fire is out of walking distance and the elevators have firefighter service?
What are the initial actions to be taken by the Fire Attack Group?
What are the initial actions to be taken by the Fire Attack Group?
What should crews do if elevators do not have firefighter recall service?
What should crews do if elevators do not have firefighter recall service?
Flashcards are hidden until you start studying