What type of electrical distribution systems can the MODULYS XM be installed in?
What type of electrical distribution systems can the MODULYS XM be installed in?
- Only TN systems
- Only single-phase systems
- Any of TN, TT, and IT systems (correct)
- Only TT systems
In the context of external protection for UPS, what must be done if the UPS is likely to be subject to transient overvoltages?
In the context of external protection for UPS, what must be done if the UPS is likely to be subject to transient overvoltages?
- Provide additional external protection (correct)
- Install an internal protective circuit only
- No additional measures are needed
- Use a smaller PE cable
What configuration options does the MODULYS XM offer?
What configuration options does the MODULYS XM offer?
- No configuration options available
- Only output switches without a bypass option
- Manual bypass with various switch options (correct)
- Automatic bypass only
What must be ensured regarding the protective earthing conductor (PE)?
What must be ensured regarding the protective earthing conductor (PE)?
To determine the PE cable core size, which factor should be considered?
To determine the PE cable core size, which factor should be considered?
What type of residual current detector should be used for a fourpole selective configuration?
What type of residual current detector should be used for a fourpole selective configuration?
What should be done before installing a Residual Current Detection (RCD) system?
What should be done before installing a Residual Current Detection (RCD) system?
What is the maximum circuit breaker switch rating for a C Curve circuit breaker?
What is the maximum circuit breaker switch rating for a C Curve circuit breaker?
If using an external transformer, what type of circuit breaker should be used?
If using an external transformer, what type of circuit breaker should be used?
What is the I²t limit for ensuring bypass thyristor integrity in a standard UPS system?
What is the I²t limit for ensuring bypass thyristor integrity in a standard UPS system?
What is the short-time withstand current (Icw) for a high short-circuit system?
What is the short-time withstand current (Icw) for a high short-circuit system?
What is the minimum power cable size required for a 10-module N+1 redundant system?
What is the minimum power cable size required for a 10-module N+1 redundant system?
What must be considered when loads with high leakage currents are present in a system?
What must be considered when loads with high leakage currents are present in a system?
What is indicated by the A000 alarm code?
What is indicated by the A000 alarm code?
Which alarm indicates that the UPS’s load is exceeding its power specification?
Which alarm indicates that the UPS’s load is exceeding its power specification?
What should be done when the A012 MAINTENANCE ALARM is triggered?
What should be done when the A012 MAINTENANCE ALARM is triggered?
When is the A009 ENERGY SAVER DISABLED BY UPS alarm activated?
When is the A009 ENERGY SAVER DISABLED BY UPS alarm activated?
What does the A005 INSUFFICIENT RESOURCES alarm indicate?
What does the A005 INSUFFICIENT RESOURCES alarm indicate?
If the A018 END OF BACK-UP TIME alarm is triggered, what does it signify?
If the A018 END OF BACK-UP TIME alarm is triggered, what does it signify?
What does the A016 BATTERY DISCONNECTED alarm mean?
What does the A016 BATTERY DISCONNECTED alarm mean?
Which alarm indicates that environmental temperature is too high for optimal UPS functionality?
Which alarm indicates that environmental temperature is too high for optimal UPS functionality?
What is the main purpose of switching onto maintenance bypass?
What is the main purpose of switching onto maintenance bypass?
What should be done when an external manual bypass is present while switching onto maintenance bypass?
What should be done when an external manual bypass is present while switching onto maintenance bypass?
How often should the batteries be recharged when the UPS is deactivated for an extended period?
How often should the batteries be recharged when the UPS is deactivated for an extended period?
What is the first step in switching on from maintenance bypass?
What is the first step in switching on from maintenance bypass?
What operation should be performed to interrupt the supply to the output load quickly?
What operation should be performed to interrupt the supply to the output load quickly?
What should you check before recharging the batteries of a deactivated UPS?
What should you check before recharging the batteries of a deactivated UPS?
Which option must be selected from the MAIN MENU to start the UPS after maintenance bypass?
Which option must be selected from the MAIN MENU to start the UPS after maintenance bypass?
What action should be taken with the external battery breaker before opening Q5?
What action should be taken with the external battery breaker before opening Q5?
What is the maximum total harmonic distortion input current allowed?
What is the maximum total harmonic distortion input current allowed?
Which frequency range is acceptable for the input mains?
Which frequency range is acceptable for the input mains?
What is the recommended operating temperature range for optimal performance?
What is the recommended operating temperature range for optimal performance?
How many modules are included for the Pout of 500 kW?
How many modules are included for the Pout of 500 kW?
What is the minimum power factor specified for the input?
What is the minimum power factor specified for the input?
What is the maximum allowable storage temperature?
What is the maximum allowable storage temperature?
What is the crest factor requirement for the system?
What is the crest factor requirement for the system?
Which of the following statements about bypass input voltage is true?
Which of the following statements about bypass input voltage is true?
What is the maximum altitude specified without derating?
What is the maximum altitude specified without derating?
What is the total output voltage distortion percentage allowed phase-to-neutral?
What is the total output voltage distortion percentage allowed phase-to-neutral?
Study Notes
Residual Current Detection (RCD) Guidelines
- RCD should be upstream of input and auxiliary mains connections, utilizing a common configuration is not recommended.
- Use four-pole type B selective residual current detectors.
- Load leakage currents from UPS and power failure phases can lead to short current peaks; adjust residual protection accordingly.
- Pre-check earth current leakage with UPS operational to avoid RCD tipping.
Recommended Protection Devices
- Redundant Systems require a specific number of modules to manage power (kW): e.g., 100+0(1) for 2 modules, 100+50 for 3 modules, scaling up to 600+50 for 13 modules.
- Use a C curve circuit breaker with a minimum of 200 A based on module count; max limit of 1250 A for all configurations.
- For external transformers, select a D curve selective breaker.
Short-Time Withstand Current (Icw)
- Standard systems should aim for 20 kA rms; high short-circuit systems can allow up to 35 kA rms.
- Contact Socomec for specifics related to achieving 65 kA rms with optional bypass configurations.
UPS and Overvoltages
- Designed for transient overvoltages in category III; requires additional protection in category IV installations.
- Protective earthing conductor (PE) must handle sufficient current capacity, with cable size reflecting protective current rating dependencies.
MODULYS XM Overview
- Configurations include standard system (manual bypass) and systems with extra bypass module options.
- Control panel and power module slots are accessible from the front view.
Bypass Operations
- Maintenance bypass allows direct connection of UPS input and output; essential during maintenance and serious failures.
- Instructions are provided through the control panel menu for transitioning into and out of maintenance bypass mode.
Extended Out of Service Procedures
- Batteries must be recharged every three months when UPS is offline.
- Initiate charging by connecting mains, switching on input, and following procedures through the control panel.
Emergency Shutdown Procedures
- Quick power interruption requires engaging switch Q3.
- Remote shutdown can be executed via ADC + SL board.
Alarm Management
- Alarms categorized into external (e.g., input/output, temperature) and internal circuits that require corrective action by service departments.
- Specific alarms include imminent stops, overloads, high ambient temperature, and various operational warnings.
Power and Input Specifications
- Input voltage ranges from 340 V to 480 V (±20%); frequency specifications are between 40 to 70 Hz.
- Output voltage provides options for 3Ph+N configurations at 380/400/415 V ±1%, with selectable frequency ±0.01%.
Environmental Conditions
- Operating temperature optimal range is 0-40 °C, with recommended conditions between 15 °C to 30 °C.
- Operating humidity must remain at or below 95% without condensation.
Dimension and Weight Specifications
- Standard UPS dimensions are 1200 x 960 x 1990 mm.
- System weight varies based on configurations, generally around 788 to 992 kg, depending on module count.
Compliance and Safety Standards
- Compliance with EN/IEC 62040 standards ensures safety, EMC, and performance certifications.
- Testing and certifications include CE marking and protective class I adherence.