45 Questions
What does Division A of this Code contain?
Compliance and application provisions, objectives, and functional statements
What is the scope of Division B of this Code?
Acceptable solutions
What does Division C of this Code contain?
Administrative provisions
What is the rule when the Division of a referenced provision is not specified in this Code?
It shall mean that the referenced provision is in the same Division as the referencing provision
Which parts of Division A apply to all plumbing systems covered in this Code?
Parts 1, 2, and 3
Which parts of Division B apply to all plumbing systems covered in this Code?
Parts 1 and 2
Which parts of Division C apply to all plumbing systems covered in this Code?
Parts 1 and 2
What does Section 1.4 of this Code contain?
Terms and abbreviations
What happens to words and phrases used in this Code that are not included in the list of definitions?
They are considered as non-defined terms
What is the primary function of a storm sewer?
To intercept and convey storm water
What is the term for water that is discharged from a surface as a result of rainfall or snowfall?
Storm water
What is the purpose of a trap arm?
To connect the trap to the vent pipe
What is the term for a single room or series of rooms of complementary use?
Suite
What is a trap dip?
The lowest part of the upper interior surface
What is the term for the vertical distance between the trap dip and the trap weir?
Trap seal depth
What is a vent header?
A vent pipe that connects any combination of stack vents or vent stacks to outside air
What is the term for a pipe that is installed underground to intercept and convey subsurface water?
Subsoil drainage pipe
What is the term for the highest part of the lower interior surface of a trap?
Trap weir
Why can't compliance with objectives and functional statements be demonstrated in isolation?
Because they are entirely qualitative
What does Clause 1.2.1.1.(1)(b) establish?
Quantitative performance targets
How are the performance targets defined in Division B?
Not very precisely
What is the goal of demonstrating compliance with Clause 1.2.1.1.(1)(b)?
To show it's as well as a design that satisfies Division B
What represents the residual level of risk deemed acceptable by Canadians?
The risk remaining once the applicable acceptable solutions in Division B have been implemented
What happens when Division B offers a choice between several possible designs?
They may not all provide exactly the same level of performance
What is the purpose of demonstrating compliance with Clause 1.2.1.1.(1)(b)?
To show that an alternative solution is as well as a design that would satisfy the applicable acceptable solutions in Division B
What defines the boundaries between acceptable risks and unacceptable risks?
Division B
How many designs are offered in Division B?
Several
What is the main concern addressed in this Code in relation to resources?
Excessive use of water
What are the National Code Documents that have a master list of objectives?
National Building Code, National Energy Code for Buildings, National Fire Code, and National Plumbing Code
What does the term 'the building or facility' refer to in the objectives?
The building or facility being assessed for compliance with the National Plumbing Code
Who is included in the term 'person' in the definition of Objective OS1, Fire Safety?
Any individual in or adjacent to the building or facility, including occupants, the public, and emergency responders
Why are there gaps in the numbering sequence of the objectives?
Due to the master list of objectives covering the four principal National Code Documents
What is the purpose of listing the objectives?
To provide a master list of objectives covering the four principal National Code Documents
What is the focus of the objectives in the Code?
Building safety and environmental impact
What is the importance of the National Plumbing Code?
To provide a standard for plumbing systems
What is the scope of the National Plumbing Code?
For all plumbing systems
Which ASTM standard specifies the requirements for pipe, steel, black and hot-dipped, zinc-coated, welded and seamless?
ASTM A53/A53M-18
What is the scope of ASSE/ASME/CSA ASSE 1002-2015/ASME A112.1002-2015/CSA B125.12-15?
Anti-siphon fill valves for water closet tanks
What is the scope of ASSE/ASME/CSA ASSE 1016-2017/ASME A112.1016-2017/CSA B125.16-17?
Performance requirements for individual showers and tub/shower combinations
Which standard specifies the requirements for forged or rolled alloy and stainless steel pipe flanges, forged fittings, and valves and parts for high-temperature service?
ASTM A182/A182M-19
What is the scope of ASSE 1051-2009?
Individual and branch type air admittance valves for sanitary drainage systems
Which standard specifies the requirements for seamless and welded austenitic stainless steel tubing for general service?
ASTM A269/A269M-15a
What is the scope of ASSE/ASME/CSA ASSE 1037-2015/ASME A112.1037-2015/CSA B125.37-15?
Performance requirements for pressurized flushing devices for plumbing fixtures
What is the scope of ASSE/ASME/CSA ASSE 1070-2015/ASME A112.1070-2015/CSA B125.70-15?
Performance requirements for water temperature limiting devices
Which standard specifies the requirements for building services piping?
ASME B31.9-2017
This quiz covers the scope of Division A, B, and C of the Building Code, including compliance, acceptable solutions, and administrative provisions. Learn about the organization and structure of the Code. Test your knowledge of the different divisions and their contents.
Make Your Own Quizzes and Flashcards
Convert your notes into interactive study material.
Get started for free