If the air conditioner malfunctions and emits a burning smell, what is the most appropriate first step to take?
If the air conditioner malfunctions and emits a burning smell, what is the most appropriate first step to take?
- Immediately stop operation and consult authorized service personnel after disconnecting the power supply. (correct)
- Attempt to diagnose the problem using the troubleshooting guide.
- Continue operation to see if the smell dissipates.
- Reduce the power setting and monitor the unit closely.
Why is it important to avoid blocking the intake grille and outlet port of the air conditioner?
Why is it important to avoid blocking the intake grille and outlet port of the air conditioner?
- To reduce the noise level during operation.
- To prevent damage to the air filters.
- To comply with the manufacturer's warranty terms.
- To ensure efficient airflow and prevent the unit from overworking. (correct)
In a multi-split type air conditioning system, what determines the system operation mode (cooling or heating)?
In a multi-split type air conditioning system, what determines the system operation mode (cooling or heating)?
- The average of all indoor unit temperature settings.
- The outdoor unit controls, based on both indoor and outdoor unit settings. (correct)
- The settings of the most recently turned on indoor unit.
- The settings of the indoor unit in the room requiring the most cooling or heating.
During prolonged operation, why is occasional ventilation of the room recommended?
During prolonged operation, why is occasional ventilation of the room recommended?
What should you do if the remote control is not effectively transmitting signals to the air conditioner?
What should you do if the remote control is not effectively transmitting signals to the air conditioner?
What is the purpose of the 'Auto Change Over' feature in the air conditioner?
What is the purpose of the 'Auto Change Over' feature in the air conditioner?
How often should the air purifying filter be replaced, according to the maintenance guidelines?
How often should the air purifying filter be replaced, according to the maintenance guidelines?
Why should you avoid generating heat or using heating appliances while the air conditioner is in cooling mode?
Why should you avoid generating heat or using heating appliances while the air conditioner is in cooling mode?
If the unit is in heating mode and the operating indicator is blinking, what does this typically indicate?
If the unit is in heating mode and the operating indicator is blinking, what does this typically indicate?
What is the recommended action if the air conditioner is not performing sufficiently, even after ensuring the temperature setting is correct?
What is the recommended action if the air conditioner is not performing sufficiently, even after ensuring the temperature setting is correct?
Flashcards
What is an inverter in an air conditioner?
What is an inverter in an air conditioner?
At the start, it uses high power to reach the set temperature quickly, then switches to a low power setting for efficiency and comfort.
What is Vertical Air swing?
What is Vertical Air swing?
The automatic movement of air supply in a vertical direction to spread conditioned air evenly.
What does 'Auto Change Over' Mean?
What does 'Auto Change Over' Mean?
The air conditioner automatically switches between cooling, dry, and heating to maintain a constant set temperature.
What is the Sleep Time function?
What is the Sleep Time function?
Signup and view all the flashcards
Why avoid very low room temperatures?
Why avoid very low room temperatures?
Signup and view all the flashcards
How to position the air flap?
How to position the air flap?
Signup and view all the flashcards
What happens after a Power failure?
What happens after a Power failure?
Signup and view all the flashcards
Humidity level for cool/dry mode?
Humidity level for cool/dry mode?
Signup and view all the flashcards
What happens during "Low outdoor temperature" in cool/dry mode?
What happens during "Low outdoor temperature" in cool/dry mode?
Signup and view all the flashcards
What should you always do before maintenance?
What should you always do before maintenance?
Signup and view all the flashcards
Study Notes
Features and Functions
- The inverter uses a large power initially to quickly cool the room during operation
- Then the unit automatically switches to a lower power setting for comfortable and economic operation
- A wireless remote control unit allows for convenient control of the air conditioner
- Automatic vertical swing adjusts the supply air
- The flap automatically moves in an upward and a downward direction to evenly spread the conditioned air throughout the room
- Auto change over automatically switches operation mode, either cooling, dry, or heating, to maintain a set temperature
- While the unit is in sleep mode, during heating the thermostat setting is gradually lowered
- While the unit is in sleep mode, during cooling, the thermostat setting is gradually raised
- Once the period of sleep time function is reached, the unit automatically turns off
Operating Temperature Range for DC Inverter
- Cooling:
- Indoor Upper Limit: 32°C DB, 23°C WB
- Indoor Lower Limit: 17°C DB, 12°C WB
- Outdoor Upper Limit: 50°C DB
- Outdoor Lower Limit: -15°C DB
- Heating:
- Indoor Upper Limit: 30°C DB
- Indoor Lower Limit: 0°C DB
- Outdoor Upper Limit: 30°C DB, 24°C WB
- Outdoor Lower Limit: -15°C DB, -16°C WB
Precautions
-
Dangers: - Do not attempt to install the air conditioner yourself - This unit contains no user-serviceable parts, always contact a professional for repairs - When moving the unit, contact a professional for disconnection and installation - Do not become excessively chilled by staying int he direct airflow - Do not insert fingers or objects into outlet/intake grilles - Do not start/stop the unit by disconnecting the power cord - Take care to not damage the power supply cord - In the event of a malfunction, stop operation disconnect the power and consult a professional - If the power supply cord is damaged, it should only be replaced by a professional due to special tools being required - Young children or infirm persons shoould not use the appliance without supervision - Pre-heat the air conditioner for at least 12 hours before operation and keep the power on when using for extended periods
-
Cautions: - Provide occasional ventilation during use - Do not direct airflow at fireplaces or heating apparatuses - Do not climb on or place objects on the air conditioner - Do not hang objects from the indoor unit - Do not set flower vases or water containers on top of the air conditioner - Do not expose the air conditioner directly to water - Do not operate the air condition with wet hands - Do not pull the power supply cord - Turn off the power source when not using the unit for extended periods of time - Check the condition of the installation stand for damage - Do not place animals or plants in the direct path of the airflow - Do not drink the water drained from the air conditioner - Do not use in applications involving the storage of foods, plants or animals, precision equipment or art works - Be careful, connection valves become hot during heating - Do not apply heavy pressure to radiator fins - Only operate the unit with air filters installed - Do not block or cover the intake grille and outlet port - Ensure that any electronic equipment is at least one meter away from either the indoor or outdoor units - Avoid installing the air conditioner near a fireplace or other heating apparatus - When installing the indoor and outdoor units, take precautions to prevent access to infants - Do not use inflammable gasses near the air conditioner
Parts of the Air Conditioner
- The indoor unit includes:
- Display
- Front panel
- Guide louver
- The remote control is wireless
- The outdoor unit includes:
- Bind tape
- Connection wire
- Drainage pipe
Operation Tips
- A suitable room temperature should be set, excessively low rooms temperatures are bad for health and waste electricity
- The frequent adjustment of the temperature should be avoided
- Avoid direct sun during cooling, keep curtains and blinds closed, close doors and windows to keep cool air inside
- Generating heat or using heating appliances while the air conditioner is in cooling mode should be avoided
- Air flap should e positioned for horizontal flow when cooing, and downward vertical flow for heating
- Room temperature should be kept uniform by adjusting the left/right vertical air blades
- Position the air flaps to prevent your body from being exposed to direct drafts
- During prolonged operation, ventilate the room occasionally by opening a window
- During a power failure the microprocessor retains memory
- When restarted after power failure, operation will resume to the lat mode
- if the timer was used, the unit will be turned off by the timer, if not, timer data may be erased
- After turning the unit on, allow more than three minutes for cooling, heating, and dry operation to start
- When useing DRY mode, the room temperature should be between 20°C and 27°C, if used out of this range the unit may protect itself
- When using COOL or DRY modes, make sure that the rooms relative humidity is blow 78%, high humidity may for moisture
- Remote control signals may not be received if the indoor units cover is exposed to direct sunlight or strong lighting
- The remote control is only operative in a range of eight meters
Protection Modes
- Several automatic protection modes enable operation virtually at any time, regardless of temperature
- In COOL and DRY modes:
- When the outdoor temperature is too low, it protects from the indoor coil freezing up by stopping the outdoor fan and compressor, resuming when appropriate
- When the outdoor temperature is too high, it protects from the outdoor coil overheating, then stopping the compressor when appropraching over heating, resuming when appropriate
- In HEATING mode:
- When the outdoor temperature is loo low, it protects from outdoor coil ice build up by reversing operation from heating to cooling, indicator will blink
- Where there is high indoor or outdoor temperature mode, protects from outdoor coil overheating, the outdoor fan and compressor stop, then it automatically resumes Note: When switching the unit to OFF after heating, the unit may perform outdoor coil deicing operation, that may make the compressor still run
Care and Maintenance
- Before performing any maintenance procedure, make sure to disconnect the air conditioner from the power
- To clean the air filter:
- Lift the panel, push the air filters up slightly to unlock them
- Pull out the filters and clean in warm soapy water, dry thoroughly, align and put back in place
- Do not operate the unit without filters
- To replace the purification filter, this shouold occur once a year
- Pulling out the filter
- Replacing the filter in its place
- Note: This procedure is also used for active carbon filters
- To clean the air conditioner
- Wipe the unit with a soft dry cloth or lean with a vacuum cleaner, do not use hot water
- At the start of the season:
- Make sure there are no obstacles blocking the flow of air
- Make sure the power is properly connected
- To protect the electronic system:
- Indoor unit and remote should stay a least 1 meter a way from other electronic appliances
- Protect the unit from lighting and direct sun
Troubleshooting
- If the unit doesn't operate and the indicator doesn't light up:
- The unit might not be connected to power, or there is a power failure
- Attempt to plug in the power cord, and check the main fuse
- If a unit doesn't operate but indicator lights are on:
- There could be remote control malfunctions
- Check the remote control batteries and try operating from a closer distance
- If a unit does not respond properly to the remote control command:
- The remote could be locked
- The IR signal may not reach the unit
- Distance could be too large or at an improper angle
- Unlock the remote, clear obstructions, and try again, or dim lighting
- If air does not blow from the indoor unit:
- De-icing is activated, use AUTO fan mode, or there is overcooling in DRY mode
- If cooling, dry, or heating does not start immediately:
- The compressor has a 3-min delayed start
- If a unit functions but does not perform sufficiently:
- Set the temperature more appropiatly
- Consult a dealer if the unit capacity is insufficient
Exception for Multi Split types units
- Could happen that a requested operation cannot be completed
- The reason for this is that the system is operating in a different mode
- Indoor unit operation modes dependent on system mode:
- Cooling active mode
- Cooling unit operation is enabled, and Heating, and Dry operations are disabled
- Auto Cool/Heat will only cool, and ventilation is enabled
- Heating active mode
- Heating unit operation is enabled, and Cooling, and Dry operations are disabled
- Auto Cool/Heat will only heat, and ventilation is enabled
- Cooling active mode