Podcast
Questions and Answers
Which edition of the CSA-B52 Mechanical Refrigeration Code is the most recent?
Which edition of the CSA-B52 Mechanical Refrigeration Code is the most recent?
- CSA-B52-18 (correct)
- CSA-B52-14
- CSA-B52-13
- CSA-B52-12
What is the purpose of the CSA-B52 Mechanical Refrigeration Code?
What is the purpose of the CSA-B52 Mechanical Refrigeration Code?
- To establish guidelines for the maintenance of mechanical refrigeration systems
- To specify the minimum requirements for the installation of mechanical refrigeration systems
- To outline the minimum requirements for the construction of mechanical refrigeration systems (correct)
- To provide the maximum requirements for the design of mechanical refrigeration systems
How many editions of the CSA-B52 Mechanical Refrigeration Code are there?
How many editions of the CSA-B52 Mechanical Refrigeration Code are there?
- 6
- 9
- 12 (correct)
- 15
According to CSA-B52, which of the following refrigeration systems is NOT covered by the standard?
According to CSA-B52, which of the following refrigeration systems is NOT covered by the standard?
According to CSA-B52, which of the following refrigerants is NOT typically used in new installations?
According to CSA-B52, which of the following refrigerants is NOT typically used in new installations?
According to CSA-B52, which code should be followed for pressure-relief protection of refrigeration system pressure vessels?
According to CSA-B52, which code should be followed for pressure-relief protection of refrigeration system pressure vessels?
According to CSA-B52, which type of machinery room is designed as unoccupied spaces with restricted access?
According to CSA-B52, which type of machinery room is designed as unoccupied spaces with restricted access?
According to CSA-B52-13, who is responsible for ensuring that the maintenance of the system is done by a certified person?
According to CSA-B52-13, who is responsible for ensuring that the maintenance of the system is done by a certified person?
If no operation and maintenance manual exists, how should the maintenance be done according to CSA-B52-13?
If no operation and maintenance manual exists, how should the maintenance be done according to CSA-B52-13?
Which of the following is covered in the informative annexes of CSA-B52?
Which of the following is covered in the informative annexes of CSA-B52?
Study Notes
Introduction to CSA-B52 Mechanical Refrigeration Code
- The most recent edition of the CSA-B52 Mechanical Refrigeration Code is not specified, but CSA-B52-13 is mentioned as a specific edition.
Purpose and Scope of CSA-B52
- The purpose of the CSA-B52 Mechanical Refrigeration Code is to establish minimum requirements for the design, construction, and operation of mechanical refrigeration systems.
- The code does not cover refrigeration systems used for air conditioning of buildings.
Refrigerants and Pressure Relief
- R-22 is not typically used in new installations according to CSA-B52.
- For pressure-relief protection of refrigeration system pressure vessels, the ASME Boiler and Pressure Vessel Code should be followed.
Machinery Room Design
- A Type II machinery room is designed as an unoccupied space with restricted access.
Maintenance and Operation
- The owner of the refrigeration system is responsible for ensuring that maintenance is done by a certified person.
- If no operation and maintenance manual exists, maintenance should be done in accordance with the manufacturer's instructions or a certified person's recommendation.
Informative Annexes
- The informative annexes of CSA-B52 cover topics such as refrigerant piping, safety procedures, and equipment installation.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
Test your knowledge on the scope and content of the CSA-B52 Mechanical Refrigeration Code with this quiz. Learn about the similarities between CSA-B51 and CSA-B52 and understand how references are written in the code.