Questions and Answers
Which edition of the CSA-B52 Mechanical Refrigeration Code is the most recent?
Which edition of the CSA-B52 Mechanical Refrigeration Code is the most recent?
What is the purpose of the CSA-B52 Mechanical Refrigeration Code?
What is the purpose of the CSA-B52 Mechanical Refrigeration Code?
How many editions of the CSA-B52 Mechanical Refrigeration Code are there?
How many editions of the CSA-B52 Mechanical Refrigeration Code are there?
According to CSA-B52, which of the following refrigeration systems is NOT covered by the standard?
According to CSA-B52, which of the following refrigeration systems is NOT covered by the standard?
Signup and view all the answers
According to CSA-B52, which of the following refrigerants is NOT typically used in new installations?
According to CSA-B52, which of the following refrigerants is NOT typically used in new installations?
Signup and view all the answers
According to CSA-B52, which code should be followed for pressure-relief protection of refrigeration system pressure vessels?
According to CSA-B52, which code should be followed for pressure-relief protection of refrigeration system pressure vessels?
Signup and view all the answers
According to CSA-B52, which type of machinery room is designed as unoccupied spaces with restricted access?
According to CSA-B52, which type of machinery room is designed as unoccupied spaces with restricted access?
Signup and view all the answers
According to CSA-B52-13, who is responsible for ensuring that the maintenance of the system is done by a certified person?
According to CSA-B52-13, who is responsible for ensuring that the maintenance of the system is done by a certified person?
Signup and view all the answers
If no operation and maintenance manual exists, how should the maintenance be done according to CSA-B52-13?
If no operation and maintenance manual exists, how should the maintenance be done according to CSA-B52-13?
Signup and view all the answers
Which of the following is covered in the informative annexes of CSA-B52?
Which of the following is covered in the informative annexes of CSA-B52?
Signup and view all the answers
Study Notes
Introduction to CSA-B52 Mechanical Refrigeration Code
- The most recent edition of the CSA-B52 Mechanical Refrigeration Code is not specified, but CSA-B52-13 is mentioned as a specific edition.
Purpose and Scope of CSA-B52
- The purpose of the CSA-B52 Mechanical Refrigeration Code is to establish minimum requirements for the design, construction, and operation of mechanical refrigeration systems.
- The code does not cover refrigeration systems used for air conditioning of buildings.
Refrigerants and Pressure Relief
- R-22 is not typically used in new installations according to CSA-B52.
- For pressure-relief protection of refrigeration system pressure vessels, the ASME Boiler and Pressure Vessel Code should be followed.
Machinery Room Design
- A Type II machinery room is designed as an unoccupied space with restricted access.
Maintenance and Operation
- The owner of the refrigeration system is responsible for ensuring that maintenance is done by a certified person.
- If no operation and maintenance manual exists, maintenance should be done in accordance with the manufacturer's instructions or a certified person's recommendation.
Informative Annexes
- The informative annexes of CSA-B52 cover topics such as refrigerant piping, safety procedures, and equipment installation.