Which edition of the CSA-B52 Mechanical Refrigeration Code is the most recent?

  • CSA-B52-18 (correct)
  • CSA-B52-14
  • CSA-B52-13
  • CSA-B52-12
  • What is the purpose of the CSA-B52 Mechanical Refrigeration Code?

  • To establish guidelines for the maintenance of mechanical refrigeration systems
  • To specify the minimum requirements for the installation of mechanical refrigeration systems
  • To outline the minimum requirements for the construction of mechanical refrigeration systems (correct)
  • To provide the maximum requirements for the design of mechanical refrigeration systems
  • How many editions of the CSA-B52 Mechanical Refrigeration Code are there?

  • 6
  • 9
  • 12 (correct)
  • 15
  • According to CSA-B52, which of the following refrigeration systems is NOT covered by the standard?

    <p>Refrigeration systems installed in residential buildings</p> Signup and view all the answers

    According to CSA-B52, which of the following refrigerants is NOT typically used in new installations?

    <p>R12</p> Signup and view all the answers

    According to CSA-B52, which code should be followed for pressure-relief protection of refrigeration system pressure vessels?

    <p>ASME Section VIII</p> Signup and view all the answers

    According to CSA-B52, which type of machinery room is designed as unoccupied spaces with restricted access?

    <p>Class T machinery rooms</p> Signup and view all the answers

    According to CSA-B52-13, who is responsible for ensuring that the maintenance of the system is done by a certified person?

    <p>The owner</p> Signup and view all the answers

    If no operation and maintenance manual exists, how should the maintenance be done according to CSA-B52-13?

    <p>According to the applicable regulation</p> Signup and view all the answers

    Which of the following is covered in the informative annexes of CSA-B52?

    <p>All of the above</p> Signup and view all the answers

    Study Notes

    Introduction to CSA-B52 Mechanical Refrigeration Code

    • The most recent edition of the CSA-B52 Mechanical Refrigeration Code is not specified, but CSA-B52-13 is mentioned as a specific edition.

    Purpose and Scope of CSA-B52

    • The purpose of the CSA-B52 Mechanical Refrigeration Code is to establish minimum requirements for the design, construction, and operation of mechanical refrigeration systems.
    • The code does not cover refrigeration systems used for air conditioning of buildings.

    Refrigerants and Pressure Relief

    • R-22 is not typically used in new installations according to CSA-B52.
    • For pressure-relief protection of refrigeration system pressure vessels, the ASME Boiler and Pressure Vessel Code should be followed.

    Machinery Room Design

    • A Type II machinery room is designed as an unoccupied space with restricted access.

    Maintenance and Operation

    • The owner of the refrigeration system is responsible for ensuring that maintenance is done by a certified person.
    • If no operation and maintenance manual exists, maintenance should be done in accordance with the manufacturer's instructions or a certified person's recommendation.

    Informative Annexes

    • The informative annexes of CSA-B52 cover topics such as refrigerant piping, safety procedures, and equipment installation.