Criteria for Technically Feasible Domestic PNG Connection
18 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the minimum land requirement for a City Gate Station (CGS) as per the PNGRB guidelines?

  • 1000 sq.m
  • 1500 sq.m
  • 2500 sq.m
  • 2000 sq.m (correct)

Which of the following should be made available to telecom services, similar to tower installation, as per the URDPFI Guidelines?

  • Building regulation modifications
  • Both b and c
  • Utility corridor
  • Right of Way (RoW) permission (correct)

What should the development authorities include in the Development Control Regulations, as per the PNGRB guidelines?

  • Provisions for telecom services
  • Right of Usage (RoU) for city roads
  • Land requirements for CGS
  • Safety norms prescribed by PNGRB (correct)

Where should land for City gas stations be provisioned?

<p>In urban extensions, avoiding congested areas (D)</p> Signup and view all the answers

What should the municipalities and development authorities make provisions for, as per the PNGRB guidelines?

<p>All of the above (D)</p> Signup and view all the answers

What should be integrated with the utility corridor, according to the URDPFI Guidelines?

<p>Telecom services including broadband (A)</p> Signup and view all the answers

Which of the following areas would be considered technically not feasible for a domestic PNG connection?

<p>An area with structurally unstable buildings and narrow lanes (B)</p> Signup and view all the answers

What type of pipeline material is mentioned in the text for domestic PNG connections?

<p>Medium-density polyethylene (MDPE) (D)</p> Signup and view all the answers

What should be ensured for the provision of domestic and trans-country pipelines?

<p>Overall safety, quality, and convenience (A)</p> Signup and view all the answers

What is a requirement mentioned in the text for a technically feasible domestic PNG connection?

<p>Provision for connecting the customer's premises with the service MDPE pipeline (D)</p> Signup and view all the answers

What should be considered when connecting the service pipeline to a customer's building?

<p>Ensuring it does not pose any hindrance or safety hazard (B)</p> Signup and view all the answers

What is NOT mentioned in the text as a requirement for a technically feasible domestic PNG connection?

<p>Availability of a nearby incineration facility (A)</p> Signup and view all the answers

What is one of the basic requirements for artificial recharge?

<p>Availability of non-committed runoff in space and time (B)</p> Signup and view all the answers

What is NOT mentioned as a criterion to be evaluated for planning an artificial recharge scheme?

<p>Evaluation of landfill site suitability for waste disposal (B)</p> Signup and view all the answers

Which of the following is considered a part of hydrological studies for artificial recharge planning?

<p>Rainfall pattern in the area (B)</p> Signup and view all the answers

Which of the following is NOT mentioned as a criterion for identifying areas suitable for artificial recharge?

<p>Areas with high potential for biodegradable waste generation (B)</p> Signup and view all the answers

What is one of the hydrogeological studies recommended for artificial recharge planning?

<p>Identification of suitable hydrogeological environment for artificial recharge (A)</p> Signup and view all the answers

Which of the following is NOT mentioned as a source of surface water supply for artificial recharge?

<p>Leachate from municipal solid waste landfills (D)</p> Signup and view all the answers

More Like This

Use Quizgecko on...
Browser
Browser